TABLE 5
System
Option
Description
Value
Default
settings
Indic
ation
Bright
Sets the brightness level for the backlight
from 10 to 100% with
increments of 10
50
Screen OFF time
Set the time to automatically turn
off the screen
after the any button was pressed last.
The screen is turned on when a signal is detected or
any button is pressed.
Selected / not selected
(from 32 sec до 4 min)
2 min
Sounds
Beep confirmation for button stroke.
Variable beep when a signal is
detected.
Selected / not selected
Selected
Time
Schedule..
Setting the schedule in AUTOMATIC MODE.
Setting the time for a single or daily recording
in the event log.
Turn ON/OFF 0-23hours
Not
selected
Once or daily
Selected / not selected
Set clock…
Setting date and time.
When the power is OFF the time is cleared.
Serial setting: HOURS
(H), MINUTES(M),
SECONDS (S), DAY (D)
and MONTH.
00:00
PC syns
Automatic synchronization with the on your
computer when using the "ST167Analyzer"
application.
Selected / not
selected
Selected
Correction
Setting of a daily clock correction
from -2 to +2 min with
increments of one
second per day.
00:00.
Relay
Turning on the relay, selecting options for the state
of the relay contacts
Normally open
Normally closed
Normally
open
Relay timer
Relay time on: 00sec –
2min
Relay time off: 00sec –
2min
2min
3sec
Vibro
Using vibrating alert
Selected / not selected
Not
selected
Fact.
defaul
ts
Reset ALL changes to its original state