Signal Hound USB-SA44B Скачать руководство пользователя страница 17

Warranty and Disclaimer |

 

Adjustments

 

13 

6.8

 

ADJUSTMENTS 

Factory adjustment software shall be used to generate new calibration constants when USB-SA44B will 
not pass calibration.  Temperature correction data is generated only at time of manufacture. 

6.9

 

OPTIONAL ACCESSORIES 

1.

 

20dB Fixed Attenuator, Mini Circuits Part # VAT-20+ 

2.

 

DC Block, Mini Circuits Part # BLK-89+ 

3.

 

SMA(m) to BNC(f) Adapter, Mini Circuits part# SM-BF50+ 

4.

 

3GHz RF Probe, p/n P-20A (made by Auburn Technology, 
(www.auburntec.com) 

6.10

 

FCC COMPLIANCE 

This device is exempt from FCC Certification under 47 CFR Part 15.103(c).  

6.11

 

CE COMPLIANCE 

This device complies with the Class B limits of CISPR 11 and all relevant requirements of EN 61326-1: 
2006.    

7

 

Warranty and Disclaimer 

© 2015 Signal Hound. All rights reserved. 

Reproduction,  adaptation,  or  translation  without  prior  written  permission  is  prohibited,  except  as 
allowed under the copyright laws. 

7.1

 

WARRANTY 

The  information  contained  in  this  manual  is  subject  to  change  without  notice.    Test  Equipment  Plus 
makes no warranty of any kind with regard to this material, including, but not limited to, the implied 
warranties or merchantability and fitness for a particular purpose.  

Test Equipment Plus shall not be liable for errors contained herein or for incidental or consequential 
damages in connection with the furnishing, performance, or use of this material.  This Test Equipment 
Plus product has a warranty against defects in material and workmanship for a period of one year from 
date of shipment.  During the warranty period, Test Equipment Plus will, at its option, either repair or 
replace products that prove to be defective. 

Содержание USB-SA44B

Страница 1: ...USB SA44B Spectrum Analyzer User Manual...

Страница 2: ...Manual 2016 Signal Hound Inc 35707 NE 86th Ave La Center WA 98629 USA Phone 360 263 5006 Fax 360 263 5007 This information is being released into the public domain in accordance with the Export Admini...

Страница 3: ...iii Contents 1 Preparing for Use 1 2 Getting Started 2 3 Theory of Operation 7 4 Troubleshooting 8 5 Calibration and Adjustment 9 6 Specifications 10...

Страница 4: ...iv 7 Warranty and Disclaimer 13...

Страница 5: ...weighing only ten ounces the Signal Hound can be used virtually anywhere 1 1 INITIAL INSPECTION Check your package for shipping damage before opening Your box should contain a USB cable a CD ROM and a...

Страница 6: ...exceed 20 dBm or damage may occur A READY BUSY LED flashes orange each time a command from the computer is processed The rear panel has three connectors 1 10 MHz Reference input automatically detecte...

Страница 7: ...Getting Started Front Rear Panels 3...

Страница 8: ...elatively immune from this effect 3 Two RF input signals spaced by 42 8 MHz will generate a spurious response halfway between the two RF input signals This spurious response will not be present when a...

Страница 9: ...settings two preamplifier settings two ADC clock frequencies and three IF gain settings when measuring signals and performing image suppression Unless you explicitly disable the automatic settings th...

Страница 10: ...surements The level of the external timebase must be 0 dBm 13 dBm is recommended to achieve optimal phase noise performance To use simply connect the timebase to the Ext Ref In after connecting the US...

Страница 11: ...odes I Q streaming This is used for real time mode frequency domain and zero span mode time domain In this mode the USB SA44B continuously mixes a fixed LO frequency with the RF input and streams the...

Страница 12: ...1 4 IF and RBW Selection The I Q data comes in over USB and is processed using an FFT with a custom Flat Top window based on the selected RBW Software and firmware limitations only allow certain very...

Страница 13: ...may consider using a low phase noise external reference or contacting us about lower phase noise options Be aware that the Signal Hound phase noise is noticably higher than a YIG based spectrum analy...

Страница 14: ...ect to external 10 MHz timebase 0 to 20 dBm Frequency Readout Accuracy reference error 1 sample 1 Marker Accuracy reference error 1 sample Resolution Bandwidth 0 1Hz to 250KHz and 5MHz 2 Spectral Puri...

Страница 15: ...ference level 0 dBm 0 25 dB Maximum Safe Input Level preamp off 15 dB atten 20dBm DC Volts 0 2V absolute maximum 16VDC option 3 Residual Responses Input terminated 100 KHz span 0 dB atten preamp on 80...

Страница 16: ...IF BW 100 KHz to 4 4 GHz 0 dBm to 70 dBm after 10 min warmup 0 25dB Maximum IF Bandwidth 240 KHz Audio Filters Low Pass Digital Windowed Sinc selectable cutoff Band Pass Available in version 2 xx leg...

Страница 17: ...and Disclaimer 2015 Signal Hound All rights reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws 7 1 WARRANTY The...

Страница 18: ...interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product No other warranty is expressed or implied Test Equipment Plus specifically disclai...

Отзывы: