Rev 4.9
SignalFire Telemetry
17
Destination RSD Stick Section
Modbus ID
– The Modbus ID of the destination Counter Stick.
Relay Channel
– Select the relay channel to switch
Current Relay State
– Shows the last value of the relay as reported to the gateway (except for IO1 module).
Clicking the Update button will refresh this value.
After filling out the table click
Write Remote Shutdown Settings to Gateway
to store the setting in the
gateway Stick.
Relay Pulse
Starting with ToolKit version 2.2.3, and Gateway Firmware version 8.22, destination relays can be configured to
pulse instead of being permanently energized or de-energized. To do so, in the
Relay Channel
drop-down
menu, select the same relay but in “(Pulse)” mode. Specify whether to pulse during run or shutdown, and
specify the pulse duration.