Note
The following installation guidelines should be observed:
•
The DIN rail must have an adequate mass connection.
•
To wire the incremental encoder, a shielded cable is required. With an RS422 encoder,
the use of shielded, twisted pair cables is recommended. The shield must be placed in
front of the module as close as possible.
•
For the motor wiring, a shielded cable is required. The shield must be placed as close
as possible to the module.
•
The shielding must be connected to a shielding bus.
The ground bus should be connected to the control cabinet when possible!
Si possible la terre doit être connectée à l'armoire de commande!
The maximum length of the encoder and motor cables is 30 m.
La longueur maximale des câbles codeur et moteur est de 30 m.
IMPORTANT:
The S-DIAS module CANNOT be connected/disconnected while voltage is applied!
IMPORTANT:
Le module S-DIAS ne peut pas être inséré ou retiré sous tension.