SR 012
S-DIAS DC MOTOR OUTPUT STAGE
Page 24
04.11.2020
7
Additional Safety Information
The Safety function “STO” is an integrated component of the DC motor output stage. It meets
all necessary requirements for safe operation in SIL 3 according to EN 62061 and in compli-
ance with PL e. Cat. 4 in accordance with EN ISO 13849-1 (not EG type tested).
CAUTION
The instructions contained in this document must be followed.
The SR 012 can only be powered by supplies that meet the requirements for
SELV or PELV in compliance with EN 60204.
For error-free operation, proper transport and storage are essential. See
chapter 9.
Installation, mounting, programming, initial start-up, operation, maintenance
and decommissioning can only be performed by qualified personnel.
Qualified personnel in this context are people, who have completed training
or have trained under supervision of qualified personnel and have been au-
thorized to operate and maintain safety-related equipment, systems and fa-
cilities in compliance with the strict guidelines and standards of safety tech-
nology. The applicable environmental conditions must be maintained.
Les instructions de cette documentation doivent être respectées.
Les composants de sécurité ne doivent être alimentés que par des alimen-
tations conformes aux exigences PELV selon la norme EN60204. Un trans-
port et un stockage approprié sont essentiels au bon fonctionnement.
L'installation, le montage, la programmation, la mise en service, l'exploitation,
la maintenance et la mise hors service des modules de sécurité
ne doivent
être effectués que par du personnel qualifié
.
En ce sens, les
personnes qualifiées
sont des personnes ayant acquis la
formation respective ou étant formées par un spécialiste pour superviser des
dispositifs, systèmes et systèmes de sécurité conformément aux directives
et normes de sécurité applicables. Les conditions environnementales appli-
cables doivent être respectées.
Содержание SR 012
Страница 17: ...S DIAS DC MOTOR OUTPUT STAGE SR 012 04 11 2020 Page 15...
Страница 19: ...S DIAS DC MOTOR OUTPUT STAGE SR 012 04 11 2020 Page 17 4 Mechanical Dimensions...
Страница 20: ...SR 012 S DIAS DC MOTOR OUTPUT STAGE Page 18 04 11 2020 5 Connector Layout...
Страница 24: ...SR 012 S DIAS DC MOTOR OUTPUT STAGE Page 22 04 11 2020 6 Wiring 6 1 Wiring Example...
Страница 33: ...S DIAS DC MOTOR OUTPUT STAGE SR 012 04 11 2020 Page 31...
Страница 35: ...S DIAS DC MOTOR OUTPUT STAGE SR 012 04 11 2020 Page 33...
Страница 37: ...S DIAS DC MOTOR OUTPUT STAGE SR 012 04 11 2020 Page 35...
Страница 48: ...SR 012 S DIAS DC MOTOR OUTPUT STAGE Page 46 04 11 2020...