SIGMATEK HGW 1033-3 Скачать руководство пользователя страница 69

 

10.1

” WIRELESS HANDHELD OPERATING PANEL 

HGW 1033-3

 

 

25.01.2019 

Page 67 

16.2.6 

Emergency Stop 

In the Safety Designer, in the “HGW_1033_3“ module, 

Safe_Input1

  and 

Safe_Input2

  are 

used for the two-channel application of the emergency stop switch. 
 
The emergency stop LED must be operated in compliance with the emergency stop standard 
EN 13850. 
 
 

WARNING

 

If the panel is not coupled or is off, the emergency stop switch has no func-
tion! The application must ensure that in such a case, the emergency stop 
switch is not illuminated. 

Si le panneau n'est pas couplé ou est éteint, l'interrupteur d'arrêt d'urgence 
n'a aucune fonction! L'application doit s'assurer que, dans un tel cas, l'inter-
rupteur d'arrêt d'urgence n'est pas allumé. 

After the emergency stop has been triggered, the emergency stop switch can 
then only be unlocked if: 

 

the cause for triggering the emergency stop has been corrected 

 

the machine can be safely restarted 

Après le déclenchement de l'arrêt d'urgence, l'interrupteur d'arrêt d'urgence 
ne peut être déverrouillé que si : 

 

la cause du déclenchement de l'arrêt d'urgence a été corrigée 

 

la machine peut être redémarrée en toute sécurité 

 

DANGER

 

Unlocking the emergency stop switch cannot trigger an automatic restart of 
the machine. 

After the application unlocks the emergency stop switch, the operator must 
be prompted to run a defined activation process. 

Le déverrouillage de l'interrupteur d'arrêt d'urgence ne peut pas déclencher 
un redémarrage automatique de la machine. 

Après que l'application ait déverrouillé l'interrupteur d'arrêt d'urgence, l'opé-
rateur doit être invité à exécuter un processus d'activation défini. 

 
 

 

Содержание HGW 1033-3

Страница 1: ...HGW 1033 3 Wireless Handheld Operating Panel Technical Manual Date of creation 06 08 2018 Version date 25 01 2019 Article number 12 246 1033 3E...

Страница 2: ...part of this work may be reproduced edited using an electronic system duplicated or dis tributed in any form print photocopy microfilm or in any other process without the express permission We reserve...

Страница 3: ...that enables the pro gramming visualization and diagnosis of processes and systems control Process data procedures and parameters are comfortably presented on the 10 1 display and can be entered or ch...

Страница 4: ...2 2 Disclaimer 8 2 3 General Safety Guidelines 9 2 4 Designated Use 10 2 5 Software Training 13 3 Residual Risks 14 3 1 Safety of the Machine or Equipment 14 3 2 Regular Technical Inspection of the E...

Страница 5: ...4 6 3 Antennae 22 4 7 Miscellaneous 23 5 Mechanical Dimensions 24 5 1 HGW 24 5 2 HGW with BWH 25 6 Interfaces 26 6 1 Connections Button 26 6 1 1 X1 USB 2 0 Type A 26 6 1 2 X2 USB 2 0 DualRole Type C...

Страница 6: ...Installation 49 9 1 Check List 49 9 1 1 Check Contents of Delivery 49 9 2 Preparing the Hardware 49 10 Operation Start up 50 10 1 Battery Power Supply 50 10 2 Configuration 51 10 3 Testing the Operat...

Страница 7: ...Screen 61 13 3 Repair 61 14 Disposal 62 15 Accessories 62 15 1 microSD Card 62 15 2 Replacement Battery 62 15 3 Antennae 62 15 4 Touch Pen 62 16 Application Information 63 16 1 Visualization 63 16 1...

Страница 8: ...required Further help and information on training and the appropriate accessories can be found on our website www sigmatek automation com Our support team is happily available to answer your question...

Страница 9: ...possible d un risque moyen de d c s ou de graves blessures si les consignes de s curit ne sont pas respect es CAUTION Identifies a low risk danger which can lead to injury or property damage if not a...

Страница 10: ...e current document can be found on our website If necessary contact our support Subject to technical changes which improve the performance of the devices The following documentation represents a serie...

Страница 11: ...r must perform a risk assessment in accordance with machine guidelines 2006 42 EG before introducing a machine to the market Before commissioning this product check that conformance with the provi sio...

Страница 12: ...pplicable environmental conditions must be maintained Les instructions contenues dans ce document doivent tre suivies Pour un fonctionnement sans erreur le transport et le stockage appropri s sont ess...

Страница 13: ...with the technical margins de scribed in this manual or the speciation s defined in the technical data see chapter 4 L utilisation non d sign e consiste en toute modification apport e au module ou l...

Страница 14: ...it is in delivery condition See chapter 8 for more information If an operating panel is not coupled and not in use keep it in a location with restricted access En outre les consignes de s curit mentio...

Страница 15: ...re Training The application is created with the software LASAL Class 2 and LASAL Screen Editor the Safety application is created using the Safety Designer Basic information on safety can be found in t...

Страница 16: ...ctive machines le fabricant de la machine doit proc der une valuation des risques y com pris les risques r siduels ventuels pr sent s par le produit Il s agit notam ment de Mouvements involontaires de...

Страница 17: ...Operation can only continue after the test was run successfully CAUTION The emergency stop illumination must be regularly checked for clear recog nition If this is no longer ensured the emergency stop...

Страница 18: ...tive of the European Parliament and of the Coun cil of 17 May 2006 on Machinery and Change to the Directive 95 16 EC machine guideline 2014 30 EU Electromagnetic Compatibility EMC guideline 2014 53 EU...

Страница 19: ...e B10D values listed here and integrated into the calculation for the entire system The Safe CPU SCP 111 must also be calculated in 3 5 Wireless System Operation CAUTION Technical changes to the devic...

Страница 20: ...lay via the on off button Charging time 3 h via USB C as well as base station at 25 C with a rising temperature and active use of the device the charge time may increase Interfaces 1x USB 2 0 Type A H...

Страница 21: ...e measurement yes 4 2 Electrical Requirements Charging voltage magnetic connector typically 19 V DC minimum 15 V DC maximum 24 V Charging current via base station up to 2 5 A at 15 5 V USB Host curren...

Страница 22: ...18 bit RGB 16 7 million colors LCD mode normal black LCD Polarizer transmissive Pixel size 0 1695x0 1965 mm Backlighting LED adjustable Contrast typically 800 1 Brightness typically 300 cd m Angle CR...

Страница 23: ...4 Shock resistance EN 60068 2 27 150 m s Vibration resistance 10 m s Protection type EN 60529 IP54 with USB cover only Free fall rough handling DIN EN 60068 2 31 1000 mm Free fall with packaging IEC 6...

Страница 24: ...wer max 25 W Antenna gain 2 4 GHz 4 dBi Peak Gain 5 GHz 5 2 dBi Peak Gain Impedance 50 Transmission angle characteristic Transmission characteristic omnidirectional Polarization linear The panels can...

Страница 25: ...tre utilis es Voir chapitre 15 3 Antennes Regularly check the screw fitting for the antennae If necessary manually tighten them or use a torque wrench 1 Nm for SMA connectors V rifiez r guli rement le...

Страница 26: ...GW 1033 3 10 1 WIRELESS HANDHELD OPERATING PANEL Page 24 25 01 2019 5 Mechanical Dimensions 5 1 HGW Dimensions 226 x 264 x 76 mm W x H x D Material housing PC ASA color RAL7024 Weight typically 1 35 k...

Страница 27: ...10 1 WIRELESS HANDHELD OPERATING PANEL HGW 1033 3 25 01 2019 Page 25 5 2 HGW with BWH Dimensions 226 x 313 x 105 mm W x H x D Weight typically 2 9 kg...

Страница 28: ...the battery life CAUTION Do not use the HGW to charge mobile phones or other devices The close proximity of these devices to the HGW can disrupt the wireless connection as well as the function of the...

Страница 29: ...autoris si le panneau de commande dispose d une connexion de s curit avec le SCP 111 Ainsi l interface peut galement tre utilis e pour la m moire USB It should be noted that many of the USB devices o...

Страница 30: ...5 Power Data WARNING The handheld operating panel can only be connected to the base station via docking Le panneau de commande portatif ne peut tre raccord la station de base que par l interm diaire d...

Страница 31: ...fement inattendu du connecteur qui peut provoquer en dommager l appareil During wireless operation use the cover provided Utilisez le capot fourni pendant le fonctionnement sans fil 6 2 2 X6 microSD C...

Страница 32: ...ANDHELD OPERATING PANEL Page 30 25 01 2019 6 3 Display 6 3 1 Underside LED Status Definition LED off Panel is off or LED was disabled via the application LED lights green Device in RUN mode freely con...

Страница 33: ...19 Page 31 6 3 2 Front 6 3 2 1 Status LEDs LED Position Color Definition User LED left green red configurable for example battery warning User LED center blue configurable for example WLAN connection...

Страница 34: ...erator must confirm that the machine number located on the respective machine matches that in the 7 segment display on the HGW This is achieved via blink codes on the base station Lors de l attelage d...

Страница 35: ...ec pr caution et maintenues l abri de toute source d interf rence m tal main Dans le cas contraire la fonction sans erreur de la connexion WLAN ne peut pas tre garantie DANGER This device contains wir...

Страница 36: ...ennae approved by SIGMATEK GmbH Co KG can be used Other antennae can damage the device as well as invalidate the radio permits Seules des antennes recommand es par SIGMATEK GmbH Co KG peu vent tre uti...

Страница 37: ...LD OPERATING PANEL HGW 1033 3 25 01 2019 Page 35 6 5 Acoustics The operating panel is equipped with an alarm signal Piezzo To avoid minimizing the spec ified volume the sound outlet must be kept free...

Страница 38: ...er defined functions These can be individually configured with LASAL Class 2 Pressing the on off button for longer than 3 seconds while on shuts the device down imme diately hard reset On Off Button D...

Страница 39: ...IRELESS HANDHELD OPERATING PANEL HGW 1033 3 25 01 2019 Page 37 6 7 Key Switch The keyswitch is two stage and evaluated via the SCP 111 connected with the HGW1033 3 For application info see 16 2 4 Key...

Страница 40: ...rmation Switch CAUTION Activating the confirmation switch is a deliberate action Do not press the confirmation switch for longer than required to confirm the affected operation L activation du bouton...

Страница 41: ...Emergency Stop illuminated The emergency stop has 2 channel construction The top of the emergency stop is illuminated when it is active For application info see 16 2 6 Emergency Stop CAUTION Please n...

Страница 42: ...s the maximum time the time can be configured using two system varia bles Runtime Remaining time SWRuntime Preset value for runtime counter Optimize the application s cyclic task Use higher capacity C...

Страница 43: ...ming the memory module Cause The program memory module is defect The user program is too large The program memory module is missing Solution Exchange the program memory module 08 RESET The CPU has rec...

Страница 44: ...am INFO 20 LOAD The program is stopped and the CPU is currently receiving a new module or pro ject INFO 21 UNZUL MODULE The CPU has received a module that does not belong to the project Solution Recom...

Страница 45: ...olution Use the correct operating system version 35 MAX IO Reserved 36 MODULE LOAD ERROR The LASAL Module or project cannot be loaded Solution Recompile and download the en tire project 37 BOOTIMAGE F...

Страница 46: ...n error has occurred during a floating point operation 60 DIAS RISC ERROR Error from the Intelligent DIAS Master Restart report error to SIGMATEK 64 INTERNAL ERROR An internal error has occurred all a...

Страница 47: ...a Possible Causes SRam configured incorrectly Battery fort he internal program memory supply is empty Solution Analyze log file Event00 log Event19 log Check configuration Change internal program memo...

Страница 48: ...EN An attempt was made to open an un known table 114 C_OUTOF_NEAR Memory allocation error 115 C_OUT OF_FAR Memory allocation error 116 C_INCOMAPTIBLE An object with the same name already ex ists but h...

Страница 49: ...as de condensation d humidit dans ou sur l appareil The HGW has an integrated battery During transport observer the applica ble national regulations Le HGW est quip d une batterie int gr e Pendant le...

Страница 50: ...ANDHELD OPERATING PANEL Page 48 25 01 2019 Due to the battery s self discharge we recommend that it be pre charged for transport mode to a level of at least 30 Deep discharge as well as damage to the...

Страница 51: ...ed components are found in the delivery please contact our cus tomer service N utilisez pas de composants endommag s Cela pourrait perturber ou en dommager votre syst me Si des composants endommag s s...

Страница 52: ...gn tiquement sensible ne se trouve prox imit imm diate de l appareil p ex cartes de cr dit cartes bande mag n tique DANGER This device is equipped strong magnets which can pose a danger to people with...

Страница 53: ...Note the minimum requirement of 20 V profile 4 or the external USB supply 10 2 Configuration The operating panel can be configured in LASAL via the USB C interface 6 1 2 or WLAN The USB interface ope...

Страница 54: ...to a third party network without triggering the error mentioned above Des probl mes peuvent survenir si un automate est connect un r seau IP contenant des modules qui ne fonctionnent pas sous un syst...

Страница 55: ...reen Also avoid laying anything on top of the touch screen This can cause operating errors undesired triggering of functions or damage to the device Ne posez pas le panneau de commande sur son cran ta...

Страница 56: ...perturb s par des d charges lectro statiques et dans certains cas ne fonctionnent plus Before any device is connected to or disconnected from the terminal the potential should be equalized by touching...

Страница 57: ...as Safety functions and the base station is coupled with a safety related control it is indicated via the activated 7 segment display which shows the machine number 10 4 4 Decoupling The operating dev...

Страница 58: ...achine ensure that the HGW is de coupled The operating panel must not be left unattended If you no longer need the operating panel decouple it and place the device in the base station See Chapter 11 S...

Страница 59: ...6 Turning Off The On off switch can be configured via LASAL Class 2 The application engineer can define procedures for turning the operating panel off Alternatively a hard shutdown is possible by pre...

Страница 60: ...le stockage s assurer que tous les capots de protection sont cor rectement plac s de sorte qu aucune contamination corps trangers ou flu ides ne p n trent dans l appareil DANGER After use store the H...

Страница 61: ...r service Panel in transport mode See chapter 8 Transport Storage HGW functional range limited Emergency stop triggered See chapter 16 2 6 Emer gency Stop Touch screen malfunc tion Operation using glo...

Страница 62: ...tistatic foam cleaner is recommended To avoid fluids clean ing solutions from getting into the housing the HGW must not be sprayed directly To clean no erosive cleaning solutions chemicals abrasive cl...

Страница 63: ...in the original packag ing when possible Otherwise packaging should be selected that sufficiently protects the product from external mechanical influences Such as cardboard filled with air cushioning...

Страница 64: ...dispose of the device by sending it to the address listed at the beginning of this document When shipping the transport regulations for devices with Lithium Ion batteries must be observed 15 Accessor...

Страница 65: ...atteint 0 et que le contr leur de s curit passe dans un tat s r The HGW and BWH form a communications unit which must be configured by trained personnel Among other things careful allocation of the w...

Страница 66: ...HGW 1033 3 10 1 WIRELESS HANDHELD OPERATING PANEL Page 64 25 01 2019 16 1 1 Visualization Example Basic HGW BWH PLC configuration For Safety examples see the Safety System Handbook...

Страница 67: ...that when coupled the HGW is automatically decoupled after 24 hours This triggers an emergency stop in the coupled machine To avoid this de couple and recouple the operating panel within 24 hours Afte...

Страница 68: ..._3 HGW WLAN 16 2 3 SF_HGW_Login Function Block A function block is provided in the Safety designer which must be implemented for the con figuration and use of the HGW 1033 3 The use of the function bl...

Страница 69: ...pas allum After the emergency stop has been triggered the emergency stop switch can then only be unlocked if the cause for triggering the emergency stop has been corrected the machine can be safely re...

Страница 70: ...e emergency stop and confirmation switches the operator must be prompted every 30 days to run a test L interrupteur cl doit tre test au moins une fois par an Pour les inter rupteurs d arr t d urgence...

Страница 71: ...itions added Order number added 29 08 2018 13 14 29 37 3 2 Guidelines 3 3 Safety Relevant Parameters 6 4 WLAN 10 Operation Start up Low voltage guideline removed Values changed text expanded Warning f...