SIGMATEK ETT 731 Скачать руководство пользователя страница 27

 

BUILD-IN TERMINAL TOUCH 

ETT 731 

 

05.12.2019 

Page 25 

15 

STOP BRKPT

 

The  CPU  was  stopped  by  a  breakpoint 
in the program. 

Info 

16 

CPU STOP

 

The  CPU  was  stopped  by  the  program-
ming software. 

Info 

17 

INT ERROR

 

The  CPU  has  triggered  a  false  interrupt 
and  stopped  the  user  program  or  has 
encountered  an  unknown  instruction 
while running the program. 

Cause: 

A non-existent operating system 
was used.  

Stack error (uneven number of 
PUSH and POP instructions).  

The user program was interrupt-
ed through a software error.  

 

Solution: 

Correct program error 

18 

SINGLE STEP

 

The  CPU  is  in  single  step  mode  and  is 
waiting for further instructions. 

Info 

19 

READY

 

A  module  or  project  was  sent  to  CPU 
and it is now ready to run the program. 

Info 

20 

LOAD

 

The program is stopped and the CPU  is 
currently  receiving  a  new  module  or 
project. 

Info 

21 

UNZUL.

 

MODULE

 

The  CPU  has  received  a  module  that 
does not belong to the project. 

Solution: 

Recompile and download the 
entire project 

22 

MEMORY FULL

 

The  operating  system  memory  /heap)  is 
too small. No memory could be reserved 
while  calling  an  internal  or  interface 
function from the application. 

Cause: 

Memory is only allocated bun not 
released.  

 

Solution  

Clear memory 

23 

NOT LINKED

 

When  starting  the  CPU,  a  missing 
module  or  a  module  that  does  not 
belong to the project was detected. 

Solution: 

Recompile and download the 
entire project 

24 

DIV BY 0

 

A division error has occurred. 

Possible Causes: 

Division by 0.  

The result of a division does not 
fit in the result register.  

 

Solution: 

Correct program error 

25 

DIAS ERROR

 

While  accessing  a  DIAS  module,  an 
error has occurred. 

Hardware problem 

26 

WAIT

 

The CPU is busy. 

Info 

Содержание ETT 731

Страница 1: ...ETT 731 Build in Terminal Touch Technical Manual Date of creation 10 02 2014 Version date 05 12 2019 Article number 07 230 731 E...

Страница 2: ...t of this work may be reproduced edited using an electronic system duplicated or dis tributed in any form print photocopy microfilm or in any other process without the express permission We reserve th...

Страница 3: ...d using this terminal A resistive touch screen serves as the input medium for process data and parameters The output is shown on a 7 WVGA TFT color display with an LED backlight With the LSE mask edit...

Страница 4: ...Conditions 5 1 5 7 WVGA Display incl Touch 6 1 6 Miscellaneous 6 2 Mechanical Dimensions 7 3 Connector Layout 8 3 1 Front 8 3 2 Status LED 8 3 3 Backside 9 3 3 1 Applicable Connectors 11 4 Cooling 12...

Страница 5: ...4 USB Interface Connections 19 8 CAN Bus Setup 20 8 1 CAN Bus Station Number 20 8 2 Number of CAN Bus Participants 20 8 3 CAN Bus Data Transfer Rate 20 9 CAN Bus Termination 21 10 Process Diagram 22 1...

Страница 6: ...RAM battery buffered Internal storage device 512 Mbyte NAND Flash Internal I O no Interfaces 2x USB 2 0 Type A 1x front 1x back 1x Ethernet 10 100 RJ45 2x CAN bus 6 pin Weidm ller 1x RS232 9 pin DSub...

Страница 7: ...1 In US according to Class 2 UL 1310 or UL 61010 1 3rd edition chapter 9 4 or LPS limited power supply UL 60950 1 or Limited Energy UL 1585 1 3 Terminal Dimensions 180 x 135 x 40 9 mm W x H x D Materi...

Страница 8: ...mm x 0 1790 mm Number of pixels 800 3 RGB x 480 Active surface 154 08 mm x 85 92 mm Backlighting LED Contrast 500 1 Brightness typically 280 cd m Visible field left and right 70 below 70 above 50 1 If...

Страница 9: ...BUILD IN TERMINAL TOUCH ETT 731 05 12 2019 Page 7 2 Mechanical Dimensions...

Страница 10: ...he USB port or function correctly Therefore it is recommended that every USB stick be tested before actual use 3 2 Status LED Run green ON from activation of the voltage supply until processing of the...

Страница 11: ...BUILD IN TERMINAL TOUCH ETT 731 05 12 2019 Page 9 3 3 Backside X1 CAN 1 6 pin Weidm ller plug n c do not use Pin Function 1 CAN A CAN LOW 2 CAN B High 3 CAN A CAN LOW 4 CAN B High 5 GND 6 n c...

Страница 12: ...2 0 Type A X4 RS232 D Sub X5 Ethernet 10 100 RJ45 Pin Function 1 CAN A CAN LOW 2 CAN B High 3 CAN A CAN LOW 4 CAN B HIGH 5 GND 6 n c Pin Function 1 5 V 2 D 3 D 4 GND Pin Function 1 DCD 2 Rx 3 Tx 4 DT...

Страница 13: ...les qui ne fonctionnent pas sous un syst me d exploitation SIGMATEK Avec de tels dispositifs les paquets Ethernet peuvent tre envoy s l automate avec une fr quence tellement lev e c d diffusion que le...

Страница 14: ...ss can reach up to 7 5 Watts To ensure the necessary air circula tion for cooling the following mounting instructions must be followed 5 Mounting Instructions The following distance from the housing s...

Страница 15: ...BUILD IN TERMINAL TOUCH ETT 731 05 12 2019 Page 13 A mounting position of 60 to 120 is also required...

Страница 16: ...ATTENTION If the device is not supplied for 2 years the battery is empty Battery order number 01 690 055 MANUFACTURER DATA Lithium battery RENATA 3 0 V 235 mAh Use batteries from RENATA with the labe...

Страница 17: ...LD IN TERMINAL TOUCH ETT 731 05 12 2019 Page 15 6 1 Exchanging the Battery Option 1 1 Disconnect the ETT 731 supply 2 Open the seven locking screws Torx on the back of the terminal with a Tx9 screwdri...

Страница 18: ...cuit Other wise a defect can be caused in the terminal 5 Using the strap remove the battery from the holder 6 Insert the new battery with the correct polarity plus side facing the back of the terminal...

Страница 19: ...tion 2 1 The SRAM data are saved in the Flash using the CLI command SRAM Save ATTENTION If the data are not first saved the settings of the terminal are lost 2 Disconnect the ETT 731 supply 3 Loosen t...

Страница 20: ...p 6 Insert the new battery with the correct polarity plus side facing the back of the terminal Lay the sticker lifted in step 5 back over the battery place the back panel of the terminal back on and t...

Страница 21: ...gnals can therefore be prevented from reaching the electronics and affecting the function 7 3 ESD Protection Typically USB devices keyboard mouse are not equipped with shielded cables These devices ar...

Страница 22: ...ts on the CAN bus depends on the cable length termi nation resistance data transfer rate and the drivers used in the participants With a termination resistance of 120 at least 100 participants are pos...

Страница 23: ...21 9 CAN Bus Termination In a CAN bus system both end modules must be terminated This is necessary to avoid transmission errors caused by reflections in the line The termination is made by an internal...

Страница 24: ...ETT 731 BUILD IN TERMINAL TOUCH Page 22 05 12 2019 10 Process Diagram...

Страница 25: ...he time can be configured using two system varia bles Runtime time remaining SWRuntime pre selected value for the runtime counter Solution Optimize the application s cyclic task Use higher capacity CP...

Страница 26: ...memory module Cause The program memory module is defect The user program is too large The program memory module is missing Solution Exchange the program memory module 08 RESET The CPU has received the...

Страница 27: ...Info 20 LOAD The program is stopped and the CPU is currently receiving a new module or project Info 21 UNZUL MODULE The CPU has received a module that does not belong to the project Solution Recompil...

Страница 28: ...the correct operating system version 35 MAX IO Reserved 36 MODULE LOAD ERROR The LASAL Module or project cannot be loaded Solution Recompile and download the entire project 37 BOOTIMAGE FAILURE A gen...

Страница 29: ...rred during a floating point operation 60 DIAS RISC ERROR Error from the Intelligent DIASMaster Restart report error to SIGMATEK 64 INTERNAL ERROR An internal error has occurred all appli cations are...

Страница 30: ...SRam data Possible Causes SRam configured incorrectly Battery fort he internal program memory supply is empty Solution Analyze log file Event00 log Event19 log Check configuration Change internal pro...

Страница 31: ...as made to open an un known table 114 C_OUTOF_NEAR Memory allocation error 115 C_OUT OF_FAR Memory allocation error 116 C_INCOMAPTIBLE An object with the same name already exists but has a different c...

Страница 32: ...ETT 731 BUILD IN TERMINAL TOUCH Page 30 05 12 2019 243 LSL LOAD 252 CONTINUE 253 PRERUN The application is started 254 PRERESET The application is ended 255 CONNECTION BREAK...

Страница 33: ...effect fades after the screen has been turned off for some time or when dynamic content is displayed damage from the permanent effect is irreversible This effect can have the following causes Operati...

Страница 34: ...ectly on the terminal The cleaning solution should not be allowed to reach the terminal electron ics for example through the ventilation slots No erosive cleaning solutions chemicals abrasive cleanser...

Страница 35: ...d to actual hardware 19 04 2016 4 1 1 Performance Data Table updated 15 11 2016 28 11 Status and Error Messages Error code 75 added 28 11 2016 6 1 5 WVGA Display Pixel size updated 06 12 2016 5 6 14 1...

Страница 36: ...ETT 731 BUILD IN TERMINAL TOUCH Page 34 05 12 2019...

Отзывы: