C-IPC EXPANSION CARD         

 

Ethernet cable connection 

 

Twisted pair cable connection (expansion card to a HUB) 

 

8

1

 

 
 
Both ends of the network cable have this assignment (not cross-linked). 
 

It's badly recommended to use this assignment, otherwise the impedance of the network 

cable is incorrect and the maximum cable length of 100 m cannot be reached! 

 
 

Twisted pair cable connection (expansion card to other Ethernet devices) 

 
 

8

1

 

 
 
 
At direct connection without HUB the network cable has to be cross-linked. Therefore both 
ends have a different assignment (Tx/Rx cross-linked). 
 

It's badly recommended to use this assignment, otherwise the impedance of the network 

cable is incorrect and the maximum cable length of 100 m cannot be reached! 

Pin 

Function 

Cable (both sides) 

Tx+ 

Orange 

Tx- 

Orange/white 

Rx+ 

Green 

not assigned 

Blue 

not assigned 

Blue/white 

Rx- 

Green/white 

not assigned 

Brown 

not assigned 

Brown/white 

Pin 

Function (side 1) 

Cable (side 1) 

Cable (side 2) 

Tx+ 

Orange 

Green 

Tx- 

Orange/white 

Green/white 

Rx+ 

Green 

Orange 

not assigned 

Blue 

Blue 

not assigned 

Blue/white 

Blue/white 

Rx- 

Green/white 

Orange/white 

not assigned 

Brown 

Brown 

not assigned 

Brown/white 

Brown/white 

16.04.2010 Page 

Содержание 01-460-011

Страница 1: ...on card the C IPC can be expanded with up to 4 further interfaces The special design allows an easy installation and fixation of the expansion card The delivery of the expansion card also includes the...

Страница 2: ...ng 2 x M2x4 cheese head screw with serrated lock washer DIN 6798 A 2 2 Standardization UL E247993 COM3 COM4 Article numbers Version LPT RS23 2 RS4XX MDB RS23 2 RS4XX TTY Ethernet 01 460 011 YES 01 460...

Страница 3: ...C IPC EXPANSION CARD Mechanical dimensions 16 04 2010 Page 3...

Страница 4: ...C IPC EXPANSION CARD Connections X4 Ethernet 2 X1 LPT1 X2 COM3 X3 COM4 Page 4 16 04 2010 a...

Страница 5: ...RxB B Master Transmit 5 DTR n u n u 34 VDC 6 GND GND GND Master Receive 1 2 6 5 Pin LPT FDD Pin LPT FDD 1 Data Strobe n u 14 Autofeed Density Select 2 Data 0 Index 15 Error Head Select 3 Data 1 Track...

Страница 6: ...table Specification X4 Ethernet 2 8 pole RJ45 8 1 Multi Drop bus MDB supply Terminal RS232 RS 422 RS 485 TTY 20 mA 1 RxD TxA A Tx 2 RTS TxB B Tx 3 TxD RxA A Rx 4 CTS RxB B Rx 5 DTR n u n u 20 mA 6 GN...

Страница 7: ...re both ends have a different assignment Tx Rx cross linked It s badly recommended to use this assignment otherwise the impedance of the network cable is incorrect and the maximum cable length of 100...

Страница 8: ...oping into the SO DIMM socket afterwards press the card into the socket clamp and finally screw it with the cheese head screw and the serrated lock washer on the pe riphery The removal is executed con...

Страница 9: ...C IPC EXPANSION CARD Assembly of the cover plate Put the cover plate vertically on the C IPC stick the pins into the cuts and screw on the expansion card 16 04 2010 Page 9...

Страница 10: ...C IPC EXPANSION CARD Page 10 16 04 2010...

Отзывы: