OSD Menu

 

MAIN 

INFORMATION   

DOME  SETTINGS   

(   MOTION   )  

RESTART 

FACTORY 

EXIT 

MOTION 

(     PRESET     ) 

(      SCAN       ) 

(  SEQUENCE  ) 

(    PATTERN   ) 

 

BANK   EXIT 

3.3.3  SEQUENCE

 

SEQUENCE 

SEQ  NO. : 1 

START 

(SEQUENCE  SET) 

INTERVAL : 005 

DELETE 

 

BACK    EXIT 

       

The dome supports 8 groups of auto cruise 

and each cruise supports 32 presets. . Please 

check the following steps to set up cruise.

 

 

1. SEQ NO.: Move the cursor here and press 

IRIS OPEN to enter the setup of Sequence Num-

ber. Move the joystick to select a preset number 

(1-8) and press IRIS OPEN to confirm.

 

 

2.

 

START

Move the cursor here and press IRIS 

OPEN to   delete/start the current sequence.

 

 

3.

 

SEQUENCE SET

Move the cursor here and 

press IRIS OPEN to enter. Move the cursor to 

EDIT and press IRIS OPEN enter edit mode of 

sequence. Move the joystick left and right to 

select each item. 

a. When the < > is on the item NO., move 

joystick up or down to select the Serial NO. of the 
preset in a sequence. There are up to 32 presets in 
each sequence. 

b.When the < > is on the item PRESET, move 

the joystick up or down to select the 
preset NO. that the user wants to add in 
the sequence. 

c. When the < > is on the last item, move the 

joystick up or down to select edition 
mode as “INS (insert)”, “ok” and 
“delete”. 

        Press IRIS OPEN when selecting INS to insert 
the settings into the position of current Serial No. 
        Press IRIS OPEN when selecting OK to over-
ride the settings of 
        Current Serial No.:  
Press IRIS OPEN when selecting delete to delete 
the settings of the Current Serial No. 
        Press IRIS OPEN to save all the setting and 
press IRIS CLOSE  to exit 

4.

 

INTERVAL

Each preset interval is 1—60s

 

5.

 

DELETE

Move the cursor here and press 

IRIS OPEN to   delete/start the current sequence.

  

OSD Menu

 

Содержание PTZ-205AHD

Страница 1: ...AHD PTZ CAMERA USER MANUAL V1 0...

Страница 2: ...Page2 Product Overview 4 1 1 Features 5 1 2 Function 9 1 3 Technical Data 9 Common Operation 10 After Sales Service 31 Lightning and Surge Protection 33 Directory OSD Menu 11...

Страница 3: ...the video and control signal in a decent distance from high voltage devices and cable If necessary please take measures for lighting protection and anti surge protection Don t apply power to dome befo...

Страница 4: ...to set camera module supports private mask function Built in 4 alarm inputs 2 alarm outputs optional some models without this function Alarm triggering The alarm can trigger preset auto scan cruising...

Страница 5: ...e camera to a particular position The user can store recall and clear the presets easily and promptly by using the keyboard controller The dome can store up to 256 presets Auto Scan Users can set up t...

Страница 6: ...Back Light Compensation In the highly bright background auto back light compensation is aiming to compensate the brightness of the dark object and adjust the background brightness to get a clear image...

Страница 7: ...orts baud rate of 9600bps 4800bps 2400bps Set the No 1 4 dip switch for the protocol configuration Baud Rate Setup Set the No 5 6 dip switch for the baud rate configuration Dome Address Encoding sheet...

Страница 8: ...0 0 0 0 14 0 1 1 1 0 0 0 0 15 1 1 1 1 0 0 0 0 16 0 0 0 0 1 0 0 0 17 1 0 0 0 1 0 0 0 18 0 1 0 0 1 0 0 0 19 1 1 0 0 1 0 0 0 20 0 0 1 0 1 0 0 0 21 1 0 1 0 1 0 0 0 22 0 1 1 0 1 0 0 0 23 1 1 1 0 1 0 0 0 24...

Страница 9: ...connector There is no further notice when the specification parameters are changed 28 0 0 1 1 1 0 0 0 29 1 0 1 1 1 0 0 0 30 0 1 1 1 1 0 0 0 31 1 1 1 1 1 0 0 0 32 0 0 0 0 0 1 0 0 253 1 0 1 1 1 1 1 1 2...

Страница 10: ...SD Menu Operations 1 Call Preset 95 to enter the main OSD menu or call preset No 1 two times continu ously within two seconds 2 Control the joystick to move the cursor around the menu 3 Press Iris Ope...

Страница 11: ...erature voltage Use the following steps to display the System Information screens 1 Click up down to choose 2 Press IRIS OPEN The INFORMATION screen opens MAIN INFORMATION DOME SETTINGS MOTION RESTART...

Страница 12: ...he smaller the number is the lower light of the environment will be when the IR LED is on 3 NEAR POWER 1 100 adjustable 4 FAR POWER 1 100 adjustable 5 COMPENSATION class 0 3 when IR LED near light ope...

Страница 13: ...RIS OPEN to confirm 3 AUX ON Move the cursor to AUX ON click IRIS ON to enter setting mode move the joystick up and down to select ON 1 2 status click IRIS OPEN to confirm 4 RESET When the wiper hide...

Страница 14: ...ong 30 sec 1min 5 min 10 min and 30 min And press IRIS OPEN to confirm 2 ACTION Move the cursor to ACTION and press IRIS OPEN to enter Move the joystick to select the actions including NONE PRESET SCA...

Страница 15: ...as Preset 1 Scan Dome starts auto scan Default as auto scan 1 SEQ Dome runs auto cruise Default as auto cruise 1 Pattern Dome runs pattern Default as Pattern 1 ALARM OUT Move the cursor to ALARM OUT C...

Страница 16: ...NITE MAIN DOME SETTINGS IR LED WIPER IDLE ALARM PRIVACY MASK ADVANCED OTHERS BACK EXIT ADVANCED FOCUS MODE PUSH FOCUS LIMIT 1M5 VIDEO TYPE PAL AUX SOFT LIMIT DOME SPEED POWER ON ACTION TILT ANGLE BACK...

Страница 17: ...TYPE MAIN DOME SETTINGS IR LED WIPER IDLE ALARM PRIVACY MASK ADVANCED OTHERS BACK EXIT ADVANCED FOCUS MODE PUSH FOCUS LIMIT 1M5 VIDEO TYPE PAL AUX SOFT LIMIT DOME SPEED POWER ON ACTION TILT ANGLE BACK...

Страница 18: ...NITE MAIN DOME SETTINGS IR LED WIPER IDLE ALARM PRIVACY MASK ADVANCED OTHERS BACK EXIT ADVANCED FOCUS MODE PUSH FOCUS LIMIT 1M5 VIDEO TYPE PAL AUX SOFT LIMIT DOME SPEED POWER ON ACTION TILT ANGLE BACK...

Страница 19: ...TYPE MAIN DOME SETTINGS IR LED WIPER IDLE ALARM PRIVACY MASK ADVANCED OTHERS BACK EXIT ADVANCED FOCUS MODE PUSH FOCUS LIMIT 1M5 VIDEO TYPE PAL AUX SOFT LIMIT DOME SPEED POWER ON ACTION TILT ANGLE BACK...

Страница 20: ...IRIS OPEN to enter to select ON or OFF to enable or disable this function FOCUS MODE PUSH FOCUS LIMIT 1M5 VIDEO TYPE PAL AUX SOFT LIMIT DOME SPEED POWER ON ACTION TILT ANGLE BACK EXIT MAIN INFORMATION...

Страница 21: ...PRIVACY MASK ADVANCED OTHERS BACK EXIT ADVANCED FOCUS MODE PUSH FOCUS LIMIT 1M5 VIDEO TYPE PAL AUX SOFT LIMIT DOME SPEED POWER ON ACTION TILT ANGLE BACK EXIT 3 2 6 7 POWER ON ACTION POWER UP ACTION AC...

Страница 22: ...own to select the angle 0 10 degree and press IRIS OPEN to confirm MAIN INFORMATION DOME SETTINGS MOTION RESTART FACTORY EXIT DOME SETTINGS IR LED WIPER IDLE ALARM PRIVACY MASK ADVANCED OTHERS BACK EX...

Страница 23: ...IRIS OPEN to confirm 4 STOP TIME To set up the time that dome will stops after receiving the last command Options include 5 15 30 60 Sec Setting method move cursor to STOP TIME click IRIS OPEN to set...

Страница 24: ...or here and press IRIS OPEN to enter Move the dome to a defined posi tion as preset point and press IRIS OPEN to save the preset position 4 DELETE Move the cursor here and press IRIS OPEN to delete th...

Страница 25: ...the user can mover the joystick to control the PAN movement of the dome to a defined position and press IRIS OPEN to confirm then the present position will be saved as the left right limit 3 LIMIT DE...

Страница 26: ...ed different model setting option maybe different click IRIS OPEN to confirm MAIN INFORMATION DOME SETTINGS MOTION RESTART FACTORY EXIT DOME SETTINGS IR LED WIPER IDLE ALARM PRIVACY MASK ADVANCED OTHE...

Страница 27: ...rt the current scan 3 LEFT RIGHT LIMIT Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as left limit right limit and press IRIS OPEN to save this left right bound...

Страница 28: ...ence Move the joystick left and right to select each item a When the is on the item NO move joystick up or down to select the Serial NO of the preset in a sequence There are up to 32 presets in each s...

Страница 29: ...PEN to confirm 2 START Move the cursor here and press IRIS OPEN to start the current pattern tour 3 SET Move the cursor here and press IRIS OPEN to enter Move the dome up down left right make the zoom...

Страница 30: ...ings remotely under this menu Move the cursor here and press IRIS OPEN to enter Select OK or CANCEL to continue the reset or cancel the reset MAIN INFORMATION DOME SETTINGS MOTION RESTART FACTORY EXIT...

Страница 31: ...the setting to factory default setting Move the cursor here and press IRIS OPEN to enter Select OK or CANCEL to continue the reset or cancel the reset MAIN INFORMATION DOME SETTINGS MOTION RESTART FAC...

Страница 32: ...paid Don t operate in accordance with User s Manual to cause damage The damage caused by force majeure factors such as lighting and fire etc The damage caused by other manufacturer s poor design and m...

Страница 33: ...bsolutely forbidden by wiring overhead way In strong thunderstorms or high induction voltage region e g high voltage transformer substation must be taken to add extra high power lightning protection e...

Страница 34: ...nce Is Not Greater Than 4 Steel Tube Protector Vedio Arrester Communication Arrester Power Source Arrester Lightning Rod The Speed Dome Must Be Intalledin The Range Of Lightning Rod Under 45 Degrees A...

Отзывы: