OSD Menu
MAIN
INFORMATION
DOME SETTINGS
( MOTION )
RESTART
FACTORY
EXIT
MOTION
( PRESET )
( SCAN )
( SEQUENCE )
( PATTERN )
BANK EXIT
3.3.3 SEQUENCE
SEQUENCE
SEQ NO. : 1
START
(SEQUENCE SET)
INTERVAL : 005
DELETE
BACK EXIT
The dome supports 8 groups of auto cruise
and each cruise supports 32 presets. . Please
check the following steps to set up cruise.
1. SEQ NO.: Move the cursor here and press
IRIS OPEN to enter the setup of Sequence Num-
ber. Move the joystick to select a preset number
(1-8) and press IRIS OPEN to confirm.
2.
START
:
Move the cursor here and press IRIS
OPEN to delete/start the current sequence.
3.
SEQUENCE SET
:
Move the cursor here and
press IRIS OPEN to enter. Move the cursor to
EDIT and press IRIS OPEN enter edit mode of
sequence. Move the joystick left and right to
select each item.
a. When the < > is on the item NO., move
joystick up or down to select the Serial NO. of the
preset in a sequence. There are up to 32 presets in
each sequence.
b.When the < > is on the item PRESET, move
the joystick up or down to select the
preset NO. that the user wants to add in
the sequence.
c. When the < > is on the last item, move the
joystick up or down to select edition
mode as “INS (insert)”, “ok” and
“delete”.
Press IRIS OPEN when selecting INS to insert
the settings into the position of current Serial No.
Press IRIS OPEN when selecting OK to over-
ride the settings of
Current Serial No.:
Press IRIS OPEN when selecting delete to delete
the settings of the Current Serial No.
Press IRIS OPEN to save all the setting and
press IRIS CLOSE to exit
4.
INTERVAL
:
Each preset interval is 1—60s
5.
DELETE
:
Move the cursor here and press
IRIS OPEN to delete/start the current sequence.