background image

 

SD160BTex_BA_en_008.docx 

 

 

32 

 

 
 

Содержание SD161BTex

Страница 1: ...8 92899 74 Mannheim HRB 703603 D 74928 H ffenhardt info sigmann delta de Gesch ftsf hrer UstIDNr DE257944309 http www sigmann delta de Joachim Kraus Date 11 02 2020 Operating Instructions Bluetooth Ha...

Страница 2: ...SD160BTex_BA_en_008 docx...

Страница 3: ...Tex Basis 11 5 4 Technical Data Base Charging Station SDX61BTex Basis 3rd 12 5 5 Type Numbers 1D Scanner SD161BTex 13 5 6 Serial Number 13 5 7 Application 13 6 System Assembly 1D Scanner SD161BTex 14...

Страница 4: ...eration 23 10 1 Preparation SD161BTex SD261BTex 3rd for System assembly 1 2 23 10 2 Using base charging station for system 1 24 10 3 Using base charging station for system 2 25 10 4 Pin assignment pow...

Страница 5: ...SD160BTex_BA_en_008 docx 3 1 Product range Bluetooth scanner Zone 1...

Страница 6: ...4 SD160BTex_BA_en_008 docx 2 Scanner overview Wired Bluetooth 1D PDF 2D SD160ex SD160exPDF SD260ex 3rd SD161BTex SD161BTex PDF SD261BTex 3rd...

Страница 7: ...119 0000 00 SD 11C 0000 00 SD161BTex SD 118 0000 0X SD Z10 0035 00 Base station for non hazardous area SD Z10 0013 0X SD Z10 0012 0X With USB Connection PC USB Interface Wtih RS232 Connection only 5V...

Страница 8: ...ings are highlighted by a special symbol and a different font colour Danger Non compliance may result in life threatening situations This warning must be heeded Warning This type of warning concerns d...

Страница 9: ...ey have the most up to date version of the operating instruc tions To be sure this is the case please check Sigmann DELTA s website at www Sigmann DELTA de or contact one of the company s staff The dr...

Страница 10: ...d explosion protec tion is no longer guaranteed Ensure safe handling with firm footing and sufficient room for movement If the enclosure is in any way damaged the device must be removed from the hazar...

Страница 11: ...g directly into the light Brief expo sure to a class 2 laser is deemed not dangerous Maintenance Provided the device is operated and assembled according to instructions and the ambient requirements ar...

Страница 12: ...on II 2G Ex ib IIB T4 II 2G Ex ib IIB T4 Gb II 2D Ex ib IIIC T135 C II 2D Ex ib IIIC T135 C Db Certification IBExU 12 ATEX 1162 IECEx IBE 15 0017 Manufacturer Sigmann DELTA GmbH Hauptstra e 53 74928 H...

Страница 13: ...pose is to re ceive data captured by the associated handheld scanner 1D bar codes or 2D stacked codes via Bluetooth Nominal values of the hazard ous base charging station maximum input voltage Ui 4 9...

Страница 14: ...on The base charching station may be operated in hazardous areas Its purpose is to re ceive data captured by the associated handheld scanner 1D bar codes or 2D stacked codes via Bluetooth Nominal valu...

Страница 15: ...ng on voltage and interface SD 211 XX11 00 SD 119 0000 00 Explosion protected base charging station SDx61BTexBasis SD 11C 0000 00 Explosion protected base charging station SDx61BTexBasis 3rd SD Z10 00...

Страница 16: ...M125ex power supply SD 211 XX11 00 and a connection cable between the power supply and a PC External connection cable Data cable USB 0 2 2 5 mm2 4 wire or RS232 0 2 2 5 mm2 3 wire Power supply cable 0...

Страница 17: ...BTex scanner SD 118 0000 0X can also be used separately in the hazardous area The base charging station SD Z10 0035 00 is then operated in the non hazardous area Use an RS232 cable SD Z10 0012 0X or a...

Страница 18: ...Ex ib op is IIB T4 II 2G Ex ib op is IIB T4 Gb II 2D Ex ib op is IIIC T135 C II 2D Ex ib op is IIIC T135 C Db Certification IBExU 12 ATEX 1162 IECEx IBE 15 0017 Manufacturer Sigmann DELTA GmbH Haupts...

Страница 19: ...urpose is to re ceive data captured by the associated handheld scanner 1D bar codes or 2D stacked codes via Bluetooth Nominal values of the hazard ous base charging station maximum input voltage Ui 4...

Страница 20: ...e SD Z10 0010 XX SD Z10 0011 XX 5 6 V with cable SD Z 10 0007 XX maximum input current Ii 480 mA maximum input power Pi 1 25 W maximum internal inductance Li negligible maximum internal capacitance Ci...

Страница 21: ...ge and interface SD 211 XXX1 00 SD 119 0000 00 Explosion protected base charging station SDX61BTexBasis SD 11C 0000 00 Explosion protected base charging station SDX61BTexBasis 3rd SD Z10 0035 00 Non e...

Страница 22: ...the SDVM125ex power supply SD 211 XX11 00 and a connection cable between the power supply and a PC External connection cable Data cable USB 0 2 2 5 mm2 4 wire or RS232 0 2 2 5 mm2 3 wire Power supply...

Страница 23: ...1BTex 3rd scanner SD 11B 0000 00 can also be used separately in the hazardous area The base charging station SD Z10 0035 00 is then operated in the non hazardous area Use an RS232 cable SD Z10 0012 0X...

Страница 24: ...charching station 1 8 or 3 8m optional with 6m extension SDVM125ex Up to 20m Host USB SDX61BTexBasis 3rd SDX61BTexBasis Base charching station 1 8 or 3 8 m SDVM125ex Up to 5m Host RS232 Non hazardous...

Страница 25: ...r the screw has been loosened the removal of the lid requires a certain amount of force An SD Z10 0018 00 accu is required to operate the Bluetooth handheld scanner Only use this accu for the Bluetoot...

Страница 26: ...X for RS232 or SR 5 5V RS232 SD Z10 0007 XX Insert the cable in the opening at the bottom of the base charging sta tion If the cable has been inserted fully you can hear a click Check if the cable fit...

Страница 27: ...ion This connection is closed ex factory for a base charging station for hazardous areas To connect the base charging station in a non hazardous area the connection cable for the power supply and the...

Страница 28: ...he device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened Any changes to the terminal assignment may only be carried out by trained s...

Страница 29: ...ble end sleevs Base charging station RS232 RJ 45 Pin assignment Wire colours Definition Assignment 6 White TXD X9 X10 X11 4 Brown GND X12 7 Yellow UB X13 Intrinsically safe connection box of the SDVM1...

Страница 30: ...ng the device in a hazardous area you have to ensure that the enclosure has been closed fully and all screws have been tightened Any changes to the terminal assignment may only be carried out by train...

Страница 31: ...leevs Base charging station USB RJ 45 Pin assignment Wire colours Definition Assignment 2 Green D 2SL X9 10 White D 2SL X10 X11 4 Black GND X12 7 brown UB X13 Intrinsically safe connection box of the...

Страница 32: ...SD160BTex_BA_en_008 docx 30 11 1 EC type examination certificate SD160BTex and SD160BTex base charging station 11 Attachment...

Страница 33: ...31 SD160BTex_BA_en_008 docx...

Страница 34: ...SD160BTex_BA_en_008 docx 32...

Страница 35: ...33 SD160BTex_BA_en_008 docx...

Страница 36: ...SD160BTex_BA_en_008 docx 34...

Страница 37: ...35 SD160BTex_BA_en_008 docx 11 2 Certificate of Conformity SD160BTex and SD160BTex base charging station...

Страница 38: ...SD160BTex_BA_en_008 docx 36...

Страница 39: ...37 SD160BTex_BA_en_008 docx...

Страница 40: ...SD160BTex_BA_en_008 docx 38...

Страница 41: ...39 SD160BTex_BA_en_008 docx...

Страница 42: ...SD160BTex_BA_en_008 docx 40...

Страница 43: ...41 SD160BTex_BA_en_008 docx 11 3 EC type examination certificate Power supply SDVM125ex...

Страница 44: ...SD160BTex_BA_en_008 docx 42...

Страница 45: ...43 SD160BTex_BA_en_008 docx...

Страница 46: ...SD160BTex_BA_en_008 docx 44...

Страница 47: ...45 SD160BTex_BA_en_008 docx 11 4 Certificate of Conformity Power supply SDVM125ex...

Страница 48: ...SD160BTex_BA_en_008 docx 46...

Страница 49: ...47 SD160BTex_BA_en_008 docx...

Страница 50: ...SD160BTex_BA_en_008 docx 48...

Страница 51: ...49 SD160BTex_BA_en_008 docx...

Страница 52: ...SD160BTex_BA_en_008 docx 50...

Страница 53: ...51 SD160BTex_BA_en_008 docx Sigmann DELTA GmbH Hauptstra e 53 D 74928 H ffenhardt Tel 49 0 6268 92899 73 Fax 49 0 6268 92899 74 info sigmann delta de 12 Contact...