2
• In standby, the siren has seven different selectable, operating modes of the five LEDs of the
FLASH.
• Five different alarm sounds (selectable) and separate sound for fire alarm.
• It has two independent activation inputs, which operate with a positive or negative voltage
interruption and an independent activation input for fire detection.
• The siren will follow the alarm duration of the control panel. However, in case of interruption
of or short circuit of the cables that connect the siren with the Alarm Panel an alarm will be
triggered.
• Specifically:
- Sounds an alarm with duration five (5) minutes, if the power supply cables are cut-off (+12 V)
- Sounds an alarm with duration fifteen (15) minutes, if the TRIGGER cable is cut-off
- Sounds an alarm with duration five (5) minutes, if the power supply cables and TRIGGER cable
are cut-off simultaneously
• The siren, can be programmed so, when it starts operating will sound at low volume for
5 seconds and then the intensity will turn to normal level.
• The siren will sound an alarm of up to five (5) times in 24 hours (selectable). This time counts
from the first activation of the siren and the process is canceled just spend the 24 hours or if
there is siren power cut off for two seconds.
• The siren’s battery voltage is verified every hour, and when it drops below 11.5V (Low Battery),
the “FLT OUT” output (FAULT OUT) is activated. The “FLT OUT” output is also activated when
the battery is disconnected from the siren or when its voltage drops below 10 V (Battery Fail).
• When the battery voltage exceeds 13.8 V, charging is stopped to protect the battery from
overcharging.
• It has short circuit protection on the battery charging (of the cables) output. Also, it has
overcurrent and short circuit protection for the battery with simultaneous activation of the “FLT
OUT” output.
• It has protection against reverse connection of the battery poles with simultaneous LED
indication.
• When the siren is in standby mode and its battery voltage drops below 10.0 V, siren’s flash
stops flashing.
• Built in TAMRER switch to protect the siren from the opening the outer casing and the
detachment from the wall. The Tamper is provided with free contacts for connection to the
Alarm panel.
• The FSD has a built-in 3-axis accelerometer with adjustable detection sensitivity, which, in any
attempt to vandalize or change siren slope more than 45o, triggers an alarm to the siren and
simultaneously triggers the output “ALR OUT” ALARM OUTPUT).
• The FSD version has a built-in foam detector, which, in any attempt to sabotage the siren with
General Characteristics
Description
Self-powered and self-protected electronic siren with built-in FLASH 270°, in two shades (red
and blue), for easy detection of the area from which the alarm comes. It is an ideal combination
of stylish design and quality construction and is manufactured under the most, strict safety
standards. The outer cover is made of high-strength polycarbonate, suitable for outdoor use.
Inside it is protected by a metal cap made of galvanized sheet metal (in the Basic version) and it
has protection against opening the outer lid or detaching the siren from the wall. In addition, in
the IRIS PLUS / FSD version, there is a vibration detector to protect the siren from knocks and a
dual infrared foam detection sensor for protection against sabotage through foaming.