AMERICAN
AMERICAN
American Faucet & Coatings Corporation
Temperature Calibration
Cartridge Removal Guide
(Future reference ONLY)
Maintenance
Filter Cleaning
rate. It is then necessary to clean them with a
brush after removing the combination cover
cartridge (3) from the body of the appliance
(see "Cartridge Removal Guide). Brush the
temperature by actuating the bushing (12).
Note this temperature. Place the pointer
assembly (6) on the bushing and position the
“red” index opposite the graduation corre-
sponding to the temperature noted.
Tighten up the pointer assembly (6) set
When in use, if a water above 104
o
F is
desired, press the “red” index and turn the
knob to the left.
Emptying in case of Frost
When the appliance is exposed to freezing
conditions it is ESSENTIAL to empty it:
- either by turning on a tap at the bottom outlet
- or by opening the cover (3) of the appliance.
necessary to remove the cartridge from the mixing
valve - never take the cartridge apart or you will
void all warranties . Simply soak the entire cartridge
in (vinegar and water solution 50/50) for 1 to 3 hours
and reinstall the valve. 90% of the time the valve
will then work normally. See Operating Incidents for
further details.
D. Cleaning the Cartridge
Page 3
Revised 7-12-19
FORM SIG 063