SIGLENT
8 SPD3000 User Manual
Output check
The output check includes voltage check in condition of all channels with no
load and current check in condition of short circuit so as to make sure that the
instrument correctly responds to operation of the front panel.
1. Voltage output check
(1) Within no load, turn on the power, and make sure the setting current values
of all channels are not zero;
(2) Check the voltage output of CH1/CH2
Turn on CH1/CH2 and the instrument work in CV mode. Check whether the
voltage value could be changed from 0V to 32V.
2. Current output check
(1) Turn on the power.
(2) Check the current output of CH1/CH2
Use an insulated wire to connect the positive and negative terminal of
CH1/CH2;
Turn off CH1 and CH2;
Revolve the knob to set the voltage value to 32V;
Revolve the knob to set the current value to 0A;
Adjust the current parameters
to check whether the current value can be
changed from 0A to 3.2A.
www.biall.com.pl