background image

INFRA MASTER

Copyright © Sigicom AB 2003-2013

49

7.2.3 Replace Battery During Operation

Disconnect and remove 

the old battery.

Open front panel.

T20

Connect new battery to unoccupied 

battery connectors.

Insert new battery.

NOTE

Don’t let both batteries be connected at the same time 
for more than 10 seconds.

Содержание INFRA Point

Страница 1: ...INFRA MASTER ENGLISH INFRA Master Art no Master 080 04100 0 www sigicom com ML089B04100 0EnA User Manual...

Страница 2: ...M Subscription 20 4 4 CompactFlash Card Structure 21 4 5 Data Storage 22 4 6 Configurations 23 4 7 Configuration Files 26 5 Installation 27 5 1 Insert CompactFlash Card 27 5 2 Installing SIM Card 29 5...

Страница 3: ...B 2003 2013 3 1 How To Read This Manual Right Wrong or Do not Replace Recharge battery Full battery Low battery Consult the manual if you see this label on the product it means you need to consult you...

Страница 4: ...and 2 this device must accept any interference received including interference that may cause undesired operation Contains FCC ID QIPMC55I W GSM module PTCRB approved Canadian customers This Class B d...

Страница 5: ...recycling of scrapped equipment is Hans Andersson Recycling Stockholm AB with transport certificate no 562 1372 2012 L nsstyrelsen i Stockholms l n The batteries used in this equipment are governed by...

Страница 6: ...atal injury to anyone working with the INFRA Master WARNING Failure to follow warning instructions can result in minor personal injury to anyone working with the INFRA Master CAUTION Special precautio...

Страница 7: ...INFRA MASTER Copyright Sigicom AB 2003 2013 7 2 3 Transport WARNING...

Страница 8: ...t Sigicom AB 2003 2013 INFRA MASTER WARNING 2 4 Battery When charging the battery in or out of the INFRA Master place the battery or the Master in a well ventilated room away from open fire and electr...

Страница 9: ...INFRA MASTER Copyright Sigicom AB 2003 2013 9 If misused the battery may generate inflammable gas smoke or leak sulfuric acid Worn out Swollen Cracks Leaks WARNING...

Страница 10: ...mum distance 1 meter 3 ft Use original Sigicom charger with Ground Fault Circuit Interrupter GFCI outdoors Exposure to water can result in electrical shock or fire causing severe or fatal injury To av...

Страница 11: ...and reporting function The INFRA system can easily execute advanced remote and unmanned field measurements Various environmental disturbances can be measured and monitored such as vibration noise sho...

Страница 12: ...matically shut off after some minutes if its left idle in this mode REG ON In this mode all connected nodes measure and register data according to their individual specifications and settings In order...

Страница 13: ...RA I NTERNET 3 1 3 System Overview Data CompactFlash card Web presentation Produce reports Data server Internet INFRA Net Manager Presentation Produce reports Change settings SMS Email Noise sensor Vi...

Страница 14: ...indicators 3 Integrated antenna 4 LCD display 5 Maintenance port 6 Gore tex vent 7 Panel buttons 8 Nodes sensors connectors 9 External antenna connector 10 Battery charger or optional communication co...

Страница 15: ...e Robust and durable With the lid closed the INFRA Master is waterproof but must not be completely submerged 3 2 2 Type Sign 1 Bar code 2 Product name 3 Article number 4 Serial number 5 CE marking IPX...

Страница 16: ...tt Reg On INFRA Master sigicom LCD F1 F2 Comm Lo Batt Reg On INFRA Master sigicom LCD F1 F2 Comm Lo Batt Reg On INFRA Master sigicom External Antenna Sim Card No Sim Card Sim Card NOTE To attach an ex...

Страница 17: ...disturbances while Registration is running 3 2 5 CompactFlash Card A CompactFlash card is used in the INFRA Master Compact Flash Windows FAT32 NOTE To facilitate battery replacement during operation w...

Страница 18: ...A static sensor temperature water level etc has seen a value outside its thresholds A network problem is discovered for example a node is lost Master Events Data registration is turned on REG ON or o...

Страница 19: ...em Without Data Transfer To disable the GSM function just add the file conntype txt to config directory see section 4 4 and write the word off in this file NOTE During system start up the text Communi...

Страница 20: ...data if GPRS is not available with server phone number username and password SIM card Please keep notes about the number code SIM id printed on the SIM card and record in which INFRA Master the card i...

Страница 21: ...13 21 4 4 CompactFlash Card Structure config data serialno networkno startdate current year month day archive Compact flash dialcmd txt ftpserver txt ntpserver txt spool Italic names of the directorie...

Страница 22: ...tory to spool directory current archive data serialno networkno startdate archive spool data spool data serialno networkno startdate current Files which are successfully sent from spool direc tory to...

Страница 23: ...s dialcmd txt in config directory Examples Provider Access Point Name APN String to be inserted Telia GPRS online telia se at cgdcont 1 IP online telia se d 99 PPP 1 Tele2 GPRS internet tele2 se at cg...

Страница 24: ...RS Do as follows 1 Open a text editor 2 On the first row write the PPP username of your internet provider 3 Save the file as ppplogin txt in the config directory 4 Start a new file 5 On the first row...

Страница 25: ...e file as ftplogin txt in the config directory 7 Start a new file 8 On the first row write the password for your username at the ftp site 9 Save the file as ftppasswd txt in the config directory 10 St...

Страница 26: ...txt Name of the ftp server noarchive txt Used if no data should be archived on the CompactFlash card ntpserver txt The name on the Network Time Protocol NTP server ppplogin txt Login name for GSM data...

Страница 27: ...7 5 Installation 5 1 Insert CompactFlash Card T20 x4 CAUTION Make sure that the INFRA Master is completely OFF before removing inserting the CompactFlash card Be careful not to damage the CompactFlash...

Страница 28: ...28 Copyright Sigicom AB 2003 2013 INFRA MASTER Compact flash...

Страница 29: ...INFRA MASTER Copyright Sigicom AB 2003 2013 29 5 2 Installing SIM Card T20 x4 NOTE PIN CODE REMOVED PIN CODE CAUTION Make sure that the INFRA Master is completely OFF before inserting SIM card...

Страница 30: ...30 Copyright Sigicom AB 2003 2013 INFRA MASTER T20 x4...

Страница 31: ...INFRA MASTER Copyright Sigicom AB 2003 2013 31 Reposition the panel on the base frame Tighten the four screws to a distinct stop Do not over tighten SIM card 3 4mm 90...

Страница 32: ...Cabling Set Up T coupling Termination Plug Max 5 meters 16 ft drop cable length Max 500 meters 1640 ft total cable length LCD F1 F2 Comm Lo Batt Reg On INFRA Master sigicom INFRA INFRA Max 5 meters 1...

Страница 33: ...ental ground potentials may induce electric current which can affect the communication in the cabling NOTE Always terminate cables and open connections at the end of the bus Use Termination plugs art...

Страница 34: ...34 Copyright Sigicom AB 2003 2013 INFRA MASTER 5 4 Wall Mount Optional Article number 080 01850 0 ordered separately...

Страница 35: ...r setting DOWN is used to search for the proper setting If not in change mode DOWN is used to go to the next menu F2 F2 is used to select a menu go into change mode or to save new setting Indicates GS...

Страница 36: ...nsor does not respond properly This is due to INFRA Master is busy with other transactions than serving the user interface Node lost Displayed when selected sensor has not responded for three minutes...

Страница 37: ...ication Nodes Network Event Transient 1 2 Last Interval 1 LiveValue 1 Infra Master Startup Status Overview Main Menu Event Menu Pass word Master Unit Network Communication Memory Channels Channel Spec...

Страница 38: ...nodes to read their type serial no and individual settings The lower right text is debug information 4 When all parts of system are con nected a status menu will be shown for some seconds can be bypa...

Страница 39: ...Main Menu in REG ON 6 3 2 Start and Stop Measurement Registration REG ON and REG OFF Quick REG Mode can be either ON or OFF Quick REG Mode ON is the standard setting and bypasses the password which ma...

Страница 40: ...transient files 1 In the Master Unit category see Menu Tree in section 6 2 enter Working Mode Setup which is the first menu in this category 2 The password is a sequence of UP and DOWN presses 3 Pres...

Страница 41: ...3 1 Make sure REG is ON 2 Press both UP and DOWN to enter the Data Values menu and its submenu Event Transient 3 Press UP or DOWN to change which node to observe 4 The value is not updated automatical...

Страница 42: ...Press UP or DOWN to change which node to observe 4 The values are not updated automatically when new intervals are recorded Press F2 to update the display 5 Press F1 to return to Main Menu or both UP...

Страница 43: ...times to enter the Data Values menu and its submenu Live Value 3 Press UP or DOWN to change which node to observe 4 Press F2 to calculate and display the maximum value since the previous F2 pressing 5...

Страница 44: ...nus Comm Lo batt Reg On LCD F1 F2 N01 GEO V10 01027 We 23 May 12 12 23 EVNT 3 4 mm s 1LCDoff 2Menus Main Menu in REG ON and Last Event mode but there is no value to show Main Menu in REG ON and Last E...

Страница 45: ...ction can also be used as a tool to test the configuration of the GSM GPRS system and the data server During the connection a number of progress messages are displayed showing what is happening or if...

Страница 46: ...46 Copyright Sigicom AB 2003 2013 INFRA MASTER 7 Maintenance 7 1 Field Operation 7 1 1 Before Operation 7 1 2 After Operation Correct configuration Compact Flash INFRA INFRA...

Страница 47: ...INFRA MASTER Copyright Sigicom AB 2003 2013 47 NOTE It is recommended to recharge stored batteries every 6 months 7 2 Battery 7 2 1 Storage...

Страница 48: ...003 2013 INFRA MASTER 7 2 2 Replace Battery Disconnect old battery and remove T20 x4 Open front panel Connect new battery Insert new battery CAUTION Batteries must conform to UL94 or IEC 60695 11 10 w...

Страница 49: ...Sigicom AB 2003 2013 49 7 2 3 Replace Battery During Operation Open front panel T20 Connect new battery to unoccupied battery connectors NOTE Don t let both batteries be connected at the same time fo...

Страница 50: ...50 Copyright Sigicom AB 2003 2013 INFRA MASTER...

Страница 51: ...INFRA MASTER Copyright Sigicom AB 2003 2013 51 7 3 Replace Desiccant Pouch T20 x4 NOTE Replace every other year Open front panel Remove battery...

Страница 52: ...52 Copyright Sigicom AB 2003 2013 INFRA MASTER T20 x4 Lift up operator panel Locate and replace desiccant pouch...

Страница 53: ...see section 5 1 2 Check if there are files stored in the archive folders that needs to be copied If so copy the archive folders to a backup disk 3 Copy the config folder to a backup disk 4 Format the...

Страница 54: ...service and repair For service adress please see www sigicom com Support email support sigicom com PROBLEM DESCRIPTION __________________________ ________________________ LCD F1 F2 Comm Lo Batt Reg On...

Страница 55: ...d be returned to Sigicom for proper handling according to the WEEE directive 7 7 Maintenance Schedule Months 6 12 18 24 30 36 42 48 Replace Desiccant Pouch x x Recharge Unused Batteries x x x x x x x...

Страница 56: ...Back lit LCD four rows 20 characters per row Memory CompactFlash card 256 MBytes See Reference Manual for limitations and recommendations Battery Rechargable Lead Acid AGM type Absorbent Glass Mat 12...

Страница 57: ...INFRA MASTER Copyright Sigicom AB 2003 2013 57 8 2 Accessories See separate product catalog...

Страница 58: ...t and support Sigicom AB Tel 46 8 4499750 http www sigicom se or http www sigicom com Customers Web site login and password needed http support sigicom com infra Please login frequently to check for u...

Отзывы: