Hardware Bench Setup 

 

IMPORTANT

: To prevent damage to the hardware boards, use a conductive wrist strap attached to 

a good earth ground. Before picking up an ESD sensitive electronic component, discharge built up 
static by touching a grounded bare metal surface or approved anti-static mat. 

This section describes the connection for the 1500-OEM and the 1500-AB interface board to the 
supporting components. The 1500-AB board is used as the serial and network interface board. 

Cable connections: 

 

IMPORTANT:

  Se

Power Connections

 in the next section before applying power.  

 

Attach the heat sink to the top of 1500-OEM board. The heatsink has peel-and-stick backing. 

 

SLA-

CAB-2RCA:  Connects to VIN0 on the 1500-AB board and to the analog camera. 

 

SLA-

CAB-2RCA (optional analog monitor): Connects to VOUT on the 1500-AB board and to analog 

monitor. 

 

SLA-CAB-ETH0:  Connects to the Ethernet port on the 1500-AB board and to the network switch or 
host PC. A green blinking light on the 1500-OEM board verifies network connection. 

 

SLA-PWR-B05V (110-250VAC input / 5VDC output): Connects to J2 on the SLA-1500-AB board. 

 

The camera and monitor are not provided by SightLine Applications.

 

 

Figure 3: Typical Bench Hardware Setup 

Ethernet Port

 

Network Switch or PC 
Direct

 

VOUT

 

VIN1

 

VIN0

 

SLA-PWR-B05V

 

1500-OEM board + 
1500-AB Board

 

Serial (optional)

 

Analog  

Monitor

 

Analog Camera

 

    

SLA-CAB-2RCA

 

SLA-CAB-ETH0

 

SLA-CAB-2RCA

 

Heatsink

 

Camera PWR

 

The board and 
heatsink unit can 
become very warm 
during operation. 
Use care when 
handling. Do not 
remove the heatsink 
during bench 
testing. 

Содержание EAN-1500-OEM

Страница 1: ...onnections 4 6 Panel Plus 5 6 1 Camera Setup and Network Selection 7 6 2 Direct serial connection optional 7 7 Summary 8 7 1 Demo Mode 8 8 Troubleshooting 9 8 1 Questions and Additional Support 10 App...

Страница 2: ...Line Software Requirements IMPORTANT The Panel Plus software version should match the firmware version running on the board Firmware and Panel Plus software versions are available on the Software Down...

Страница 3: ...n cannot be established Figure 2 1500 AB Board Serial COM Connection 4 1500 EVAL Kit Parts listed below are included in the 1500 EVAL kit If your application calls for other options and interface boar...

Страница 4: ...and stick backing SLA CAB 2RCA Connects to VIN0 on the 1500 AB board and to the analog camera SLA CAB 2RCA optional analog monitor Connects to VOUT on the 1500 AB board and to analog monitor SLA CAB E...

Страница 5: ...v H and later AB boards place the switch in the position shown in Figure 4 To power on the 1500 OEM board For Rev E and earlier AB boards place both switches in the position shown in Figure 5 A blue l...

Страница 6: ...uld match If the board firmware version is initially unknown reference the SightLine invoice that came with the board when it was purchased 2 Launch the installer file and follow the prompts After ins...

Страница 7: ...the 1500 OEM board operating information is displayed under the Video Output section and the bottom status bar in Panel Plus If the connection was not successful this information will not be present o...

Страница 8: ...boots reconnect to the board Make sure the board connects See EAN Parameter File for a comprehensive guide to saving parameter settings See EAN Camera Compatibility for all third party cameras and len...

Страница 9: ...OEM board contact Sales 7 1 Demo Mode To enable all features for testing and evaluation purposes click the Demo Mode button from the Connect tab The video screen will have a Demo Mode screen overlay u...

Страница 10: ...cation can cause connection issues 1 Close the Panel Plus software application and open the Window Firewall Security Manager on the host PC 2 Go to Inbound rules and delete the two slapanelplus rules...

Страница 11: ...rom the main menu go to Configure Network Settings 2 If an unknown static IP address is assigned remove it or update it to match the current network addressing scheme 8 1 Questions and Additional Supp...

Страница 12: ...iption SLA 1500 ENC 1 1500 OEM 1500 mAB SLA PWR B05V 1 5V Power Phoenix SLA CAB S001 1 Serial adapter stripped SLA CAB SMA2BNC 2 SMA 2 BNC SLA CAB 2RCA 2 RCA m to RCA m SLA CAB ETH0 1 Ethernet SLA CAB...