Modbus
Register
(Decimal)
Modbus
Register
(Hex)
Function
Code
(Read)
Function
Code
(Write)
# of
Registers
Description
Range
Default
Format
Property
Comment
270
10E
3
16
1
Radio
Configuration 1-6
4
uint16
Read/
Write
RC zones
selection
1, 2 ,4 is
RCZ1,
RCZ2,
RCZ4
271
10F
3
16
1
tx_power
20
int16
Read/
Write
RF Tx
power
272
110
3
16
1
tx_repeat
0-1
1
uint16
Read/
Write
Number of
repeat, 0:
1 time, 1:
3 repeats
273
111
3
16
1
downlink_flag
0-1
0
uint16
Read/
Write
1: enable
Downlink,
0: disable
Downlink
(Fw v1.0
hasn't got
Downlink
function)
274
112
3
16
2
cycle_send_data
900
uint32
Read/
Write
Data
sending
cycle, in
seconds
278
116
3
16
1
alarm_limit
44
uint16
Read/
Write
Limit
number of
alarm
sending in
24h
280
118
3
16
2
sensor1:
sampling_rate
120
uint32
Read/
Write
Sensor/Input
1
sampling
rate, in
seconds
282
11A
3
16
2
sensor1:
calc_time
100
uint32
Read/
Write
Measurement
time of
sensor/input
1, in ms
324
144
3
16
1
enb_datagram
0x0001
hex
Read/
Write
bit 0 = 1:
enb
datagram
1
bit 0 = 0:
dis
datagram
1
bit 1 = 1:
enb
datagram
2
bit 1 = 0:
dis
datagram
2
bit 2 = 1:
enb
datagram
3
bit 2 = 0:
dis
datagram
3
enb_datagram
= 0x0000:
emb
datagram
1
7. Installation