18
2.4 MIG SYN Display
PANEL FUNCTIONS & DESCRIPTIONS
1
§3.2.5 MIG SYN display introduction
The operator simply sets the welding current like MIG welding and the machine
calculates the optimal voltage and wire speed for the material type, wire type and size
and shielding gas being used. Obviously other variables such as welding joint type and
thickness, air temperature affect the optimal voltage and wire feed setting, so the
program provides a voltage fine tuning function for the synergic program selected. Once
the voltage is adjusted in a synergic program, it will stay fixed at this variation when the
current setting is changed. To reset the voltage for a synergic program back to factory
default, change to another program and back again.
1. Welding mode button
: Press it to select MIG SYN welding mode.
2. L parameter knob
: Rotate it to adjust wire feeding speed. In functional parameter
interface, rotate it to select parameters.
3. R parameter knob
: Rotate it to adjust parameters.
4. Functional button
.
5. Manual shield gas check button.
6. Manual wire feed button.
The operator simply sets the welding current like MIG welding and the machine calculates the optimal
voltage and wire speed for the material type, wire type and size and shielding gas being used. Obviously
other variables such as welding joint type and thickness, air temperature affect the optimal voltage
and wire feed setting, so the program provides a voltage fine tuning function for the synergic program
selected. Once the voltage is adjusted in a synergic program, it will stay fixed at this variation when the
current setting is changed. To reset the voltage for a synergic program back to factory default, change to
another program and back again.
1. Welding mode button
Press it to select MIG SYN welding mode.
2. Left parameter knob
Rotate it to adjust wire feeding speed. In functional parameter interface, rotate it to select parameters.
3. Right parameter knob
Rotate it to adjust parameters.
4. Functional button.
5. Manual shield gas check button.
6. Manual wire feed button.