How to prevent automatic TURN-OFF

Switch your meter to "CONTINUOUSLY ON" mode. 

Ø

To do  this, press y

"ON/OFF" 

pushbutton  (2)  together.  The  function  "CONTINUOUSLY  ON"
is shown on the LCD (1) by the symbol           

ellow multi-function pushbutton (5) and the 

(8).

ON

Automatic TURN - OFF

The meter turns off automatically, when the measured value remains constant 
(variations of the measured value < + 2digits) for about 10 minutes and when 
neither a pushbutton nor the function selector switch is operated during that 
time.

Note:

Electric  discharges  and  high-frequency  interference  may  cause  incorrect 
information to be displayed and block the measuring process. Reset the meter 
by switching it OFF and ON again otherwise, check the battery connections.

Disconnect the meter from the measuring circuit before you open it, and see 
section "16.Maintenance"!

Repair, replacement of parts and calibration

When opening the meter, live parts may be exposed. Therefore, the meter 
must be disconnected from the measuring circuit prior to opening its case 
for repair or replacement of parts. If repair cannot be avoided unless the 
meter is opened and live, this work must only be performed by a qualified 
person who understands the danger involved.

Fausts and extraordinary stress

When  it  must  be  assumed    that  the  safe  operation  is  no  longer  possible, 
take the meter out of service and secure it against accidental use. 
It is assumed that safe operation may not be possible,

l

when the meter shows obvious signs of damage,

l

when the meter no longer functions correctly,

l

after prolonged storage under adverse conditions,

l

due to severe stress during transportation.

2. Switching the meter "ON”

Battery

Fit the 

meter with a 9V flat cell battery provided along with the meter.

Before you use the meter for the first time or after storage, refer to Section 
"16.1 Maintenance-Battery".

Switching the meter "ON”

Ø

Press the "ON/OFF" pushbutton (2).
Switch-"ON" is acknowledged by a sound signal. As long as you keep 

the pushbutton pressed, all segments of the liquid crystal display (LCD) 
will appear. The LCD is shown on page 2.

After the pushbutton is released, the meter is ready for operation.

Meaning of the symbols on the device

Warning of a danger point
(Attention, refer to the usermanual)

Earth (ground) terminal.

Double or reinforced insulation

Instrument for over voltage 
category II / III or  IV

EU conformity mark.

CAT   II / III / IV 

28

Ambient conditions

Functional temperature

0

range   

-20

Storage temperature

0

range  

-25

Climatic class   

2z/-20/50/70/75 % with ref

Altitude   

up to 

 

Mechanical configuration

Protection type    

IP 50, for the connection sockets IP 20 according to 

DIN VDE 0470 Part 1 /EN 60529

Dimensions    

84 mm x 

 

Weight   

350 g approx.,including battery 

16.   Maintenance

Caution

Disconnect the meter from the measuring circuit before you open it to replace the 
battery or the fuse! 

16.1. Battery

Prior to initial start-up, or after storage of meter, verify that the batteries of 
does not leak. Repeat this check in regular short intervals. If the battery leaks, 
completely remove the battery electrolyte carefully with a  moist cloth and install a 
new battery before you operate 

again.

When the symbol "       " (17) appears on the LCD (1) replace the battery as soon 
as possible. You can continue to measure, but a reduced measuring accuracy 
must be taken into account.

The meter operates with 9V flat cell battery according to IEC 6 F 22 or IEC6 Lr61 or 
with a suitable NiCd storage battery.

0

C...+ 50 C 

0

C...+ 70  C  

erence to VDI/VDE 3540 

2000 m

195 mm x 35 mm

meter 

meter 

Replacing the battery

Ø

Place the meter on its face, loosen the two screws on the rear and remove 
the lower part of the case, lifting it from the bottom. The lower and the upper 
part of the case are fixed together at the top on the front by means of wedges. 

Ø

Remove  the  battery  from  the  compartment  and  carefully  disconnect  the 
contacts from the battery. 

Ø

Snap the connection contacts to a new 9V battery and insert the battery in to 
the battery compartment.

Ø

Replace the lower part of the case. Start at the top on the front and take care 
that the detent hooks  are properly engaged at this point. 

Ø

Tighten the lower part with the two screws.

Ø

Please destroy the batteries in an environment friendly way.

16.2  Fuses

A blown fuse is signalled on the LCD display the instant a measured quantity 
having a voltage of more than 4 V is applied to the corresponding connection 
sockets.  Then, the digital display (9) shows "FUSE".

The 16 A fuse all other current measuring ranges.   All other measuring   ranges 
continue to function. When a fuse blows, first eliminate the cause of the overload 
using the  meter again !

 

Содержание Gamma 20

Страница 1: ... Woods Trading Estate Torquey Devan England TQ27BB Website www sifamtinsley com uk Contact Number 44 O 1803 615139 E mail info tinsley co uk Sifam Tinsley Instrumentation 3105 Creekside Village Drive Suite No 801 Kennesaw Georgia 30144 Contact Number 1 404 736 4903 Web www sifamtinsley com P R E C I S I O N I N S T R U M E N T A T I O N Gamma 20 ...

Страница 2: ...N CHARGES WILL BE REIMBURSED Thewarrantyisnotvalidinfollowingcases 1 Warrantycard dulysignedandstampedandoriginalCashMemo Invoice isnotsentalongwithMeter 2 Complete warranty card is not presented to authorised person at the time ofrepairs 3 Meter accessories is not used as per the instructions in the instruction manual 4 Defect caused by misuse negligence accidents tampering and Acts of God 5 Impr...

Страница 3: ...14 Buzzer indication 0 15 Display C for temperature measurement range 16 Sub display 1 for digits decimal point and polarity 17 Sub display 2 for digits decimal point and polarity 18 Zero adjustment indicator Symbols for displaying selected functions Contents Page 1 Safety features and safety precautions 4 2 Switching the meter on 5 3 Function and range selection 6 3 1 Auto ranging 6 3 2 Manual ra...

Страница 4: ...30 measuring adapter which is available as accessory Its internal resistance limits the measuring current in the case of over voltage and incorrect operation and safely suppress sparking from spark gaps Also refer to Section 7 1Voltage measurement on electrical systems up to 1000V withtheKS30measuringadapter Fuse replacement Ÿ Open the meter same as for battery replacement Ÿ Remove the blown fuse ...

Страница 5: ...anger point Attention refer to the usermanual Earth ground terminal Double or reinforced insulation Instrument for over voltage category II III or IV EU conformity mark CAT II III IV 28 Ambientconditions Functionaltemperature 0 range 20 Storagetemperature 0 range 25 Climaticclass 2z 20 50 70 75 withref Altitude upto Mechanicalconfiguration Protectiontype IP 50 for the connection sockets IP 20 acco...

Страница 6: ...capacitance measurement the change of switchover occurs at 2999 digits 1 digit and 280 digits 1 digit Turning the multimeter OFF Ø Press the ON OFF pushbutton 2 3 2 Manualrangeselection You can switch OFF auto ranging and select the ranges manually according to thetableonthefollowingpage Manual mode is switched OFF when pushbuttonAUTO MAN is pressed 4 for approximately 1s when the function selecto...

Страница 7: ...and two sub displays show the measurement value with correct decimal point and sign The selected unit of measure and the current type are also displayed A minus sign appears in front of the number for the measurement of zero frequency direct quantities ifthepositivepoleofthemeasuredquantityisappliedtoperpendicularinput OL overload is displayed if the actual value falls above the measuring range up...

Страница 8: ... the appropriate condition has been fulfilled according to the following table the measurementvalueisdisplayedinthelefthandsub displayandtwoacoustic signal sounds At the same time MAN appears and indicates that the measuring range is now set The test probes can now be removed from the measuring point and the measurement value can be read from the sub display If the measurement value lies below the...

Страница 9: ...ation is not influenced by data HOLD You can still read the actual measured value Note that with a held digital display the location of thedecimalpointisalsoheld As long as the data HOLD function is active manual range selection is not possible The data HOLD function is switched off when the DATA push button 3 is pressed for approximately 1 s when the function selector switch 6 is operated orwhenm...

Страница 10: ...Contin uous Contin uous 3 2 5 0 2 1 2 0 2 1 2 0 2 1 2 0 2 1 2 0 2 3 2 1 0 3 2 1 0 3 2 1 0 7 0 1 3 7 0 1 3 7 0 05 3 7 0 05 3 10 Acoustic Signal Acoustic Signal V DC 0 I5 345 V 0 I5 000 DC V DC 0 I5 I23 DATA 0 I5 345 0 I5 345 MIN MAX MIN MAX Current Meas Value Current Meas Value Current Meas Value DATA MIN MAX short DATA MIN MAX short DATA MIN MAX long DATA MIN MAX ...

Страница 11: ...st leads as shown The connected tothelowestpotentialgroundavailable socket should be Notes On the 1000 V range an intermittent sound signal warns you when the measured valueexceedstheupperrangelimit 7 1 Voltage measurement on electrical systems up to 1000V withtheKS30measuringadapter On low Voltage systems transient over voltages of several kilovolts can occur due to switching functions or lightni...

Страница 12: ...0 008 20 0 02 0 008 20 0 02 0 008 20 0 5 30 0 2 30 0 2 30 0 2 30 0 2 30 Intrinsic error of digital display 0 05 0 02 20 0 02 0 01 20 0 02 0 01 20 0 1 0 01 20 0 2 0 05 30 0 5 30 0 5 30 0 5 30 0 5 30 0 5 30 3 0 05 0 015 20 0 05 0 015 20 0 05 0 015 20 0 05 0 025 20 0 1 0 025 20 0 1 0 25 20 0 2 0 0 10 6 0 02 0 15 30 2 Overload Capacity 5 10A 1 2 0 10 10 sec 12 F W Hz V V mA 0 C A F W Hz V V mA 0 C A ...

Страница 13: ...n the LCD When selecting a range with the function selector switch 6 the DC AC function is always set by default When pressing the yellow multi function pushbutton 5 for a long time the multimeter always switches back to DC AC and acknowledges this bytwosoundsignals E Connect the multimeter in series with the load as shown Ensure thattheconnectionsaretight withoutcontactresistance mA for currents ...

Страница 14: ... function stop watch cannot be activated in the range 300 mV Ø Briefly press the yellow multifunction push button 5 00 00 00 and the stop watch symbol 17 are displayed on the LCD Ø The stop watch is started and stopped by pressing the AUTO MAN pushbutton 4 The display is n minutes seconds and tenth of seconds Ø The Time can be cleared by pressing the DATA MIN MAX push button 3 Ø Briefly press the ...

Страница 15: ...wn Ø Zeroadjustmentonthe measuringrange300Ω When measuring small resistance values on the 300 Ω range you can eliminate the resistance of the leads and contact resistance by zero adjustment Ø Connectthetestleadstothemeterandjointhefreeends Ø Brieflypresstheyellowmulti functionpushbutton 5 The meter acknowledges zero adjustment by a sound signal the LCD shows 000 00 resp 0 0000 1 digit and symbol Z...

Страница 16: ...fythemeasuredresults Ø Setthefunctionselectorswitch 6 to F Ø Connectthe discharged deviceundertesttothe sockets viatestlead and F Note Connect polarised capacitors with the __ pole to the socket Resistors and semiconductor junctions in parallel with the capacitor falsify the measuredresults Ø Connectthetestleadstothemeterwithoutdeviceundertest Ø Brieflypresstheyellowmulti functionpushbutton 5 The ...

Отзывы: