14. Stop watch
This function allows you to measure elapsed times up to one hour.
Ø
Run the function selector switch (6) to “V - - - ”
Ø
The function stop watch cannot be activated in the range 300 mV- - -
Ø
Briefly press the yellow multifunction push button (5)
“00:00:00” and the stop watch symbol (17) are displayed on the LCD.
Ø
The stop watch is started and stopped by pressing the “AUTO/MAN”
pushbutton(4). The display is ‘n’ minutes, seconds and tenth of
seconds..
Ø
The Time can be cleared by pressing the ‘DATA-MIN/MAX’ push
button (3).
Ø
Briefly press the multi function push button (6) in order to return to
voltage measurement.