Sierra SRCB-24 Скачать руководство пользователя страница 7

7 to 10 

 

 

 

 

• Installation of the equipment should be performed by qualified, certified, and authorized personnel who are 

familiar and experienced with local installation codes. 

• Before Installation please read instructions comple

tely and carefully. 

• Do not remove permanently affixed labels, warnings or plates from the product.

 

• Please observe all local and national codes and ordinances

 

• Installation must conform with local codes, or in the absence of local codes, the National

 

Fuel Gas Code, ANSI Z223.1 (latest edition). 
 
In  Canada,  installation  should  conform  to  installation  codes  for  gas  burning  appliances  and  equipment 
standard CAN/CGA-B 149.1 or the Propane installation code, CAN/CGA-B 149.2, as applicable. 
The appliance must be isolated from gas supply piping system, by closing its individual manual shut off valve 
during  any  pressure  testing  of  the  gas  supply  piping  system  at  test  pressure  equal  to  or  less  than  ½  psi 
(3.45kpa) 
 
 

CLEARANCES

   

 
The appliance area must be kept free and clear of all combustibles 
SR, SRMR Series products are for installation in Non-Combustible locations only. 

 

 

 
COMBUSTIBLE 

NON COMBUSTIBLE 

SIDES 

12 Inches 

0 Inches 

REAR 

8 Inches 

0 Inches 

FLOOR 

6 Inches 

0 Inches 

 
 
 

AIR SUPPLY & VENTILATION

 

 
The area in front of, around and above the appliance must be kept clear to avoid any obstruction of the flow of 
combustion and ventilation air. 
Adequate clearance must be maintained around the appliance for easy servicing. Provision should be made for 
any  commercial,  heavy-duty  cooking  appliance  exhaust  combustion  waste  products  to  the  outside  of  the 
building.  Usual  practice  is  to  place  the  appliance  under  an  exhaust  hood,  which  should  be  constructed  in 
accordance to the local codes. Strong exhaust fans in this hood or in the overall air conditioning system can 
produce a slight vacuum in the room and / or cause air drafts, either of which can interfere with the pilot or 
burner performance and could be difficult to diagnose.  
 
Air movement should be checked during installation. Air openings or baffles may have to be provided in the 
room, if pilot or burner outage problem persists. 
 

 
 
RATING PLATE 

Содержание SRCB-24

Страница 1: ...ION OPERATION MAINTENANCE RADIANT BROILER SRRB 12 SRRB 24 SRRB 36 SRRB 48 SRCB 24 SRCB 36 SRCB 48 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 ...

Страница 2: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les in...

Страница 3: ...onverting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspected...

Страница 4: ...ent of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit All Sierra appliances are adjusted and tested before leaving the factory effectively matching them to sea level conditions Adjustments and calibrations to assure proper operation may ...

Страница 5: ...h hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in a cold oven only Do not allow spray type oven cleaners to come into contact with the temperature probe in the oven After cleaning the oven rinse well with 1 4 cup of vinegar to one quart of clear water solution to neutralize any caustic res...

Страница 6: ...ny circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas supplier or the appliance manufactu...

Страница 7: ...ea must be kept free and clear of all combustibles SR SRMR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inches AIR SUPPLY VENTILATION The area in front of around and above the appliance must be kept clear to avoid any obstruction of the flow of combustion and ventilation air Adequ...

Страница 8: ...GAS GAS SUPPLY PRESURE CONTACT LOCAL GAS SUPPLIER PRIMARY AIR NOT ADJUSTED PROPERLY ADJUST AIR SHUTTER ORIFICE TOO BIG VERIFY ORIFICE SIZE PILOT WILL NOT REMAIN LIT PILOT FLAME NOT ADJUSTED ADJUST PILOT FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVER...

Страница 9: ...ierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional ...

Страница 10: ...0 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canadá H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...

Отзывы: