7 of 17
INSTALLATION OF LEGS OR CASTERS
LEGS ASSEMBLY:
Mount Legs on bottom of product, the appliance may be further leveled with adjustment in the foot of the leg.
GAS CONNECTION
The gas supply (service) line must be the same size or greater than the inlet line of the appliance. SIERRA
appliances use a ¾” NPT inlet.
Pipe joint compound must be resistive to Natural or LP gas.
For equipment using propane gas do not install supply lines with a diameter less than ½ under any
circumstances.
All connections must be tested with a soapy water solution before lighting any pilots.