LIMITED WARRANTY

 

MVP Group Corp., (Sierra Range, hereby referred to as “Sierra”), warrants all new cooking equipment bearing the name 
“SIERRA” and installed within the continental United States of America* or Canada to be free from defects in material or 
workmanship, under normal and regular usage and operation for a period of one (1) year following the date of original 
installation, but in no event can exceed eighteen (18) months from the date of shipment from the factory, unless specified 
otherwise. 
 
If a defect in material(s) or workmanship is detected, or found to exist within the stated period above, MVP Group Corp., at 
its sole discretion, shall either repair or replace any original part which has proven to fail within the machine, providing that 
the equipment has not been altered or tampered with in any manner, has been installed correctly as per the owner’s manual, 
and has been maintained and operated in complete accordance with this manual. The labor cost to repair or replace any part 
proven to be defective, as per above clause(s), shall be covered by MVP Group Corp., within the United States of 
America* or Canada; provided that: prior authorization for this labor was pre-approved by MVP Group Corp., the service 
work was performed by an authorized MVP Group Corp. service agent; and that this agent installed an original and genuine 
Sierra part in the machine. Any repair work performed by a non-authorized service agent remains the sole responsibility of 
the user, and MVP Group Corp. will not be held responsible. The installation of any generic part will not be valid; and 
therefore voids this warranty. All authorized labor coverage shall be limited to regular hourly rates only. Any supplemental 
hourly rates or charges, such as weekends or emergency premiums, remain the responsibility of the user. MVP Group 
Corp. (Sierra) hereby states that: warranty travel time shall be limited to, and without exception, a round-trip total of two 
(2) hours OR mileage up to a maximum of one hundred fifty (150) kilometers round-trip. Any charges exceeding those 
stated herein must have prior authorization by the factory. 
 
A special warranty covers the SRF series. These units carry the regular one (1) year parts and labor plus an additional fry 
tank warranty to the original end user only; if the fry tank leaks within the first two (2) years of operation due to a 
manufacturing defect, as confirmed by an MVP Group Corp. authorized service agent, MVP Group Corp. shall replace the 
fryer in its entirety. Any associated freight and/or installation charges shall not be included with the replacement. 
Exceptions to above warranty are: (A) Damages resulting from shipping, handling or abuse. (B) Incorrect installation 
and/or connections. (C) Adjustments or calibration of any thermostats or timers. (D) Faults due to lack of regular 
maintenance or cleaning of any internal or external part(s). (E) Replacement of any wearable items such as: baskets, grills, 
knobs, etc. (F) Excessive soot accumulation due to poor gas conditions. (G) Poor results due to: excessive or inadequate 
temperature(s) or gas pressure conditions (H) Failure to follow manual’s lighting instructions, maintenance and/or usage. 
MVP GROUP CORP. STATES THAT THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, THAT 
ARE NOT SET FORTH HEREIN. MVP GROUP CORP. SHALL ASSUME NO OTHER RESPONSIBILITY, EITHER 
DIRECT OR NON-DIRECT, OR BE LIABLE FOR ANY OTHER ADDITIONAL LOSS OR DAMAGE, WHETHER 
DIRECT OR CONSEQUENTIAL, AS A RESULT OF ITS EQUIPMENT. *Some exceptions apply. The manufacturer 
reserves the right to alter design and specifications without notice. 
*RESIDENTIAL APPLICATIONS: MVP Group Corp. assumes no responsibility nor liability for any parts, or labor 
coverage for component failure, or other damage resulting from installation in residential or non-commercial applications.  
 
“Sierra Range” is a registered trademark of MVP Group Corp. 
 
 

 
 
 

Содержание SR-10B-60

Страница 1: ...LATION OPERATION MAINTENANCE OVENS AND MULTIPLES SR 10B 60 SR 6B 24G 60 SR 4B 36G 60 SR 6B 24RG 60 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS RANGE 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 ...

Страница 2: ...ARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lis...

Страница 3: ...ll size must be changed appropriately For high altitude drill sizes call your local gas company or Factory Authorized Service Center All units are equipped with fixed orifices and cannot be adjusted If converting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate ...

Страница 4: ...IBLE COUPLINGS CONNECTORS AND CASTERS For an appliance equipped with casters the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 or Connectors for Moveable Gas Appliances CAN CGA 6 16 and a quick disconnect device that complies with the standard for Quick Disconnect Devices for Use with Gas Fuel ANSI Z21 41 or Quick ...

Страница 5: ...h the valve cover or by lifting the plate upward and accessing through the top C STANDARD OVEN Pilot gas is tapped from the main burner manifold pipe routed through tubing to a pilot safety valve and then to the pilot burner Gas flow is controlled by the safety valve Oven pilot lighting or relighting is to be completed in the following sequence 1 Turn the oven thermostat knob to off and wait 5 min...

Страница 6: ...sh on the oven liner panels Wash all the above with hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in a cold oven only Do not allow spray type oven cleaners to come into contact with the temperature probe in the oven After cleaning the oven rinse well with 1 4 cup of vinegar to one quart of ...

Страница 7: ...gas supply service line must be the same size or greater than the inlet line of the appliance SIERRA appliances use a NPT inlet Pipe joint compound must be resistive to Natural or LP gas For equipment using propane gas do not install supply lines with a diameter less than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots ...

Страница 8: ...local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 latest edition In Canada installation should conform to installation codes for gas burning appliances and equipment standard CAN CGA B 149 1 or the Propane installation code CAN CGA B 149 2 as applicable The appliance must be isolated from gas supply piping system by closing its individual manual shut off valve dur...

Страница 9: ...r openings or baffles may have to be provided in the room if pilot or burner outage problem persists RATING PLATE Information on this plate includes the model serial number BTU hour input of the burners operating gas pressure in inches WC and whether the appliance is orifices for natural or propane gas When communicating with factory about a unit or requesting for special parts or information Rati...

Страница 10: ...10 of 17 BACK SPLASH INSTALLATION Identify the assemblies to be fitted over the equipment Make sure you have all the tools and fasteners listed Item Description 1 WASHER 2 HEX HEAD SCREW M6 ...

Страница 11: ...11 of 17 ...

Страница 12: ...12 of 17 ...

Страница 13: ...13 of 17 ...

Страница 14: ... in both hinges you can find 2 pieces of it in carton legs box STEP 2 Hold onto both hinges with your hands STEP 3 Raise the door until the door is at a 45 degrees angle STEP 4 Pull the door towards you and lift up To put the door back in reverse these instructions ...

Страница 15: ...FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GAS PRESSURE INCREASE GAS PRESSURE TO...

Страница 16: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...

Страница 17: ...7 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canadá H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...