![Sierra Series 200 Скачать руководство пользователя страница 98](http://html.mh-extra.com/html/sierra/series-200/series-200_owners-manual_1266381098.webp)
98
Firmware CRC Commands
C010 (u) Boot CRC
Returns CRC values determined at last configuration reset (first boot
after programming CPU card processor, or first boot at eeprom valid
byte reset, C100). The first value in the program ROM CRC, the second
is the configuration parameter CRC in eeprom, the third is the macro
table CRC in eeprom. This can be used to determine if the processor
was properly programmed and if the default values were properly
restored by the program
C011 (u) Program CRC
Returns the current program ROM CRC. This takes about 7 seconds to
execute.
C012 (u) Eeprom parameter CRC
Returns the CRC of the current parameter space in the eeprom
C013 (u) Eeprom macro CRC
Returns the CRC of the current macro storage area in eeprom
C014 (u) Radio card program CRC
Computes the CRC of the program ROM in one radio card. Syntax is
C014r, where r is the physical port number of the radio card. This
several seconds to execute.
C015 (u) Radio card CRC status
Returns the last computed value of the radio card CRC. Syntax is
C015r. R is the physical port number.
Содержание Series 200
Страница 1: ...Sierra Radio Systems Series 200 Control System Owners Manual Version 1 2 ...
Страница 22: ...22 Radio I O II RIO II Board ...
Страница 23: ...23 Configuring the Control System ...
Страница 39: ...39 Installing New Firmware ...
Страница 48: ...48 Control System Operation ...
Страница 53: ...53 Control System Command Reference Guide ...
Страница 105: ...105 Methodology for System wide Audio Level Setting ...
Страница 109: ...109 ...
Страница 110: ...110 ...
Страница 111: ...111 Appendix ...
Страница 121: ...121 ...