![Sierra Series 200 Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/sierra/series-200/series-200_owners-manual_1266381087.webp)
87
Examples
*C2010D
sets the first port (physical port 0) as the only repeater port
*C202123456D
set ports 2,3,4,5,6 as link ports
*C2037D set port 7 to be a remote base port
Any conflicts between these commands are resolved as the command is
entered, in favor of values specified in the last command entered. The
receive signal detect qualification and unqualification delays for each radio
are set to the respective normal values for the radio type. The PL/COR
required state is set to the defaults for the radio type. Be very careful in using
these commands remotely.
Note: The change takes place immediately and a mistake can make it
difficult to control the system. Sets all group linked values for ports changed
by this command to default values (linked for local and link ports, not linked
for remote based and voip ports).
C201 (su) Sets the port type to repeater
C202 (su) Sets the port type to link
C203 (su) Sets the port type to remote base
C204 (su) Sets the port type to IRLP
C205 (su) Sets the port type to VOIP link
Содержание Series 200
Страница 1: ...Sierra Radio Systems Series 200 Control System Owners Manual Version 1 2 ...
Страница 22: ...22 Radio I O II RIO II Board ...
Страница 23: ...23 Configuring the Control System ...
Страница 39: ...39 Installing New Firmware ...
Страница 48: ...48 Control System Operation ...
Страница 53: ...53 Control System Command Reference Guide ...
Страница 105: ...105 Methodology for System wide Audio Level Setting ...
Страница 109: ...109 ...
Страница 110: ...110 ...
Страница 111: ...111 Appendix ...
Страница 121: ...121 ...