background image

4

30

Disarm/Alarms

Automatic (Timed)
Disarming

To Change Automatic

Disarming Days:

1.

Press and hold the 

[walk test]  key for 2 seconds

until you hear two beeps.

Enter the master user code.

Then,  press the 

 key

seven times until you see:

AUTO DISARM DAYS

Byp=N0 Home=YES

2.

Press the 

 key.  You

see something like this:

SMTWTFS  1234567

 

   SMTWTFS

3.

In this example, the boxes

show disarming occurs on

weekdays.  Press the number

above the letter of the day(s)

you wish to switch on or off.

4.

To exit, press the 

key.

Your system can automatically
disarm itself at preset times of
the day. This option must be
programmed into your system
by your installer.

You can change the days of the
week that Automatic Disarming
occurs by following the proce-
dure to the right.  To change the
time that disarming occurs,
contact your installer.  (See
Note 1 on page 64.)

www.ukpanels.com

Содержание S5010

Страница 1: ...Using Your Security System With Alphanumeric Keypad S5010 S5011 S5012 www ukpanels com ...

Страница 2: ...ssign or Change User Codes 8 Correcting a User Code Entry 10 How to Delete a User Code 10 Types of User Codes 11 Master User Code 11 Basic User Code 11 Kidwatch Code 12 Maid Code 14 Temporary Maid Code 15 Duress Code 17 Relay Code 17 3 Arming and Bypassing How the Arming Modes Differ 18 Quick Arming Modes 18 Exit Delays 19 Canceling an Arming Sequence 19 Full Arming 20 Quick Full Arming 20 Home Ar...

Страница 3: ...res 33 5 System Settings How to Set the Clock and Calendar 34 How to Turn the Warning Tone On Off 36 How to Turn the Chimes On Off 37 How to Turn the Backlight On Off 38 How to Change the Relay Days 39 6 System Maintenance How to Walk Test the System 40 How to Use Event Memory 41 How to Test the Bells and Sirens 42 To Start a Remote Programming Session 43 How to Test the Battery 44 How to Use Quic...

Страница 4: ...Using Multiple Keypads in an Area 55 Arming Individual Areas 55 Arming Multiple Areas 56 Disarming Individual Areas 57 Disarming Multiple Areas 57 Using the Zone Status Menu 58 Canceling Alarms 59 Resetting After an Alarm 59 8 Notes System Configurations 60 Glossary of Terms 63 Where to Place Smoke Detectors 65 How to Evacuate in an Emergency 66 www ukpanels com ...

Страница 5: ...gion monitored by a sensor or group of sensors is known as a zone Most zones will trigger an alarm only when the sys tem is armed Other sensors such as smoke detectors can trig ger an alarm at any time Your system s zones are identified on a label placed inside the door of your keypad Monitoring station personnel respond to system messages and notify emergency personnel as needed A monitoring serv...

Страница 6: ...grammed for silent alarms no bells sound A message is sent to the keypad and if connected to the monitoring station The keypad displays a warning message Personnel at the moni toring station confirm the alarm and respond accordingly Some alarms can be canceled before the siren sounds and the monitoring station is notified See Section 4 for more informa tion Intruder Sensor Triggers Alarm CONTROL P...

Страница 7: ... security system can be programmed for a learning period that can last from one to 31 days With this option you can prac tice using your system without causing any false alarms Refer to Section 8 to see if this learning period was programmed into your system During the learning period your system does two things differ ently First during an alarm you do not hear any sirens or bells Second if you h...

Страница 8: ... enter user codes and perform other functions Emergency Keys To notify your monitoring station of an emergency press and hold for two seconds until you hear an alarm Keys must be programmed to function for a medical emergency for a fire for a crime in progress MED FIRE POLICE Display Describes the system s status such as if the system is ready to arm if an alarm has occurred if a zone is faulted o...

Страница 9: ... gency key is pressed To can cel the alarm press the key and enter your user code After you press an emergency key your keypad s display shows that an emergency alarm occurred To clear the display press and hold the key for two seconds To Use Emergency Keys 1 To report a medical emer gency press and hold the key for 2 seconds until you see EMERGENCY ALARM 2 To report a fire press and hold the key ...

Страница 10: ...armed using home arming ARMED INS The system is armed using instant home arming BYPASSED ZN A zone has been bypassed meaning the zone is no longer protected FAULTED ZN The sensor in the zone has detected a condition which if the system were armed would cause an alarm For example a door may be ajar READY The system is ready to be armed NOT READY The system is not ready to be armed because a zone is...

Страница 11: ...d user number to each person who operates the system Your security system supports up to 60 users user numbers 1 through 60 If you prefer you can assign only one user code and user num ber to a group of users This is not recommended since it will then be impossible to determine which individual gave a specific command How to Enter a User Code To enter a user code simply press the four numbers in s...

Страница 12: ...ee ENGLISH Byp NO Home YES continued User codes can be created or changed as often as you like Any code you select must be four digits long You cannot use 0000 or assign the same user code to more than one user number Avoid codes that are easy to guess like 1234 The default master user code user number 1 is 5832 For security reasons be sure to change this code Do not assign the code 5832 to an oth...

Страница 13: ...want that user to have Your installer should have provided you with specific information about how your system was configured Refer to this infor mation to select the proper user number To Assign or Change a User Code continued 5 If the user s language is En glish press the key 6 If the user s language is not English press the key until the appropriate lan guage is displayed then press the key You...

Страница 14: ... Entry 1 Re enter your user code How to Delete a User Code You may delete a user code by changing that code to 0000 Follow the procedure for as signing or changing a user code described on the previ ous page To Delete a User Code 1 Change the user code to 0000 following the proce dure for assigning or chang ing a user code Some security systems include wire less keyfobs and remotes used to arm and...

Страница 15: ...your system may recognize At the top of each user code section you will see a checklist like this Items on this checklist followed by an X are features of the user code The master user can arm and disarm the system and can make other changes such as disabling your system s features and changing user codes Master User Code Standard Code _X_ Optional Code ___ Active Certain Days Times ___ Standard C...

Страница 16: ...se children come home first this option allows you to be notified if your child is not home by a certain time You can be noti fied by pager by an automated telephone call or by your moni toring station Not all monitor ing stations offer this service The Kidwatch Code is a four digit code that you can change or delete like any other user code The code is assigned to user number 11 It allows your ch...

Страница 17: ...h Code Otherwise the code works as before If you turn the Kidwatch Code on or off it re mains that way until you change it back Kidwatch Setup See Section 8 for the specifics of how the Kidwatch Code was set up on your system To Turn Kidwatch On Off 1 Press and hold the kidwatch key for 2 seconds until you hear two beeps You see ENTER MASTER USER CODE 2 Enter the master user code You see something...

Страница 18: ...ike other user codes which work any day of the week the Maid Code works only on cer tain days of the week The Maid Code is a four digit user code that you can change or delete like any other user code Your installer must have programmed your system to accept a Maid Code For sys tems without multiple areas as described in Section 7 the code is assigned to user num ber 13 It allows an individual to ...

Страница 19: ...e following display press the key START MAID TIMER Byp NO Home YES As the preceding section shows the Maid Code can be programmed to work on certain days of the week only If you prefer however you can set the Maid Code to work for the next few hours regardless of the day of the week The num ber of hours the Maid Code works depends upon your system s programming The Temporary Maid Code is assigned ...

Страница 20: ...Maid Code Timer continued If you do not see this display continue to step 3 3 You see something like this SMTWTFS8 1234567 D SMTWTFS 4 Press the key until you see an E under the 8 5 Press the key 6 Press and hold the maid key for 2 seconds un til you hear two beeps Enter the master user code You see START MAID TIMER Byp NO Home YES 7 Press the key You see something like this MAID CODE SET FOR HOUR...

Страница 21: ...ice that is connected to the control panel is turned on or off For ex ample your system can be programmed to switch the exterior lights of your building on or off when you enter a relay code Relay codes must be programmed into your system by the installer The relay code is a four digit code that you can change or delete like any other user code If you delete the relay code you will no longer be ab...

Страница 22: ...You can be inside the building when it is armed with instant home arming If some one enters the building through a protected door an alarm sounds instantly Automatic Arming optional Your system can be pre pro grammed to arm and disarm at preset times and days You cannot be inside the building when it is automatically armed See Note 1 on page 64 Quick Arming Modes If your system is programmed for q...

Страница 23: ... during the last ten sec onds As shown to the right a bar appears at the base of the display This bar represents the amount of time you have to exit and secure the building When half of the time has ex pired the bar will be half its original length EXIT NOW EXIT NOW Any arming command with an exit delay may be canceled be fore the system is armed To cancel an arming sequence enter a user code duri...

Страница 24: ... Arm the System with Quick Full Arming 1 Press and hold the key for 2 seconds until you hear two beeps Exit and se cure the building Full Arming Interior armed _X_ Perimeter armed _X_ Exit allowed _X_ Requires user code _X_ Automatically arms ___ No entry allowed ___ Quick Full Arming If your system is pro grammed for quick full arming you do not need to enter a user code If you are using a common...

Страница 25: ...er zones are armed Quick Home Arming If your system is pro grammed for quick home arming you do not need to enter a user code Home Arming Interior armed ___ Perimeter armed _X_ Exit allowed _X_ Requires user code _X_ Automatically arms ___ No entry allowed ___ To Arm the System with Home Arming Make sure the display reads READY TIME 1 Press the key You see TO ARM ENTER CODE NOW 2 Enter your user c...

Страница 26: ...you are sure no system user will open a protected door or window Quick Instant Home Arming If your system is programmed for quick instant arming you do not need to en ter a user code To Arm the System With Instant Home Arming 1 Make sure the display reads READY TIME Pressandholdthe in stant key for 2 seconds until you hear two beeps You see TO ARM ENTER CODE NOW 2 Enteryourusercode TheArm LED blin...

Страница 27: ... number above the letter of the day s you wish to switch on or off 4 To exit press the key Your system can automatically arm itself at preset times of the day At two minutes and again at one minute before the Auto matic Arming sequence begins the siren sounds twice Then the exit delay begins You must leave the building during the exit delay or an alarm sounds You can postpone the Auto matic Arming...

Страница 28: ... protected Exception Not ready Day Buzzer or Day Bell zones must be manually bypassed be fore arming can occur These are zones that cause a buzzer or bell to sound if they are faulted while the system is disarmed See Note 1 on page 64 Chirp Alert Arming With Chirp Alert Arming your system does not arm if a not ready zone exists At the end of the exit delay your system s sounders chirp You must re ...

Страница 29: ...storing bypassed zones If you manually bypass a 24 hour zone such as a glassbreak de tector that zone remains by passed until you restore it However if you manually by pass a zone that is not a 24 hour zone it is restored when you disarm the system Bypassing To Bypass a Zone 1 When a zone is faulted the display reads FAULTED ZN ZONE LOCATION 2 To bypass the zone press the key You see ZONE NUMBER E...

Страница 30: ...can bypass your system s zones Since bypassed zones are not pro tected this feature increases the likelihood that your system may be defeated To Bypass a Zone with Quick Bypassing 1 When a zone is faulted the display reads FAULTED ZN ZONE LOCATION 2 To bypass the zone press the key You see ZONE NUMBER ENTER 2 DIGITS 3 Enter the two digit zone number For zones 1 9 en ter a 0 first To Restore a Bypa...

Страница 31: ...ered the user must wait through a delay The delay lengthens as more invalid codes are entered Depending upon your system s programming the keypad lockout may not affect arming Keyswitch Arming This accessory Sierra S5051 or equiva lent allows you to arm and or disarm the system with a key Fol low the instructions provided with the switch Quick Exit This option allows you to exit a home armed build...

Страница 32: ...le its perimeter zones such as doors and windows are armed Arming begins by entering your user code If you exit the building during the exit delay the sys tem arms both the interior and perimeter zones full arming How ever if you do not exit the building the system automatically arms the perimeter zones only home arming www ukpanels com ...

Страница 33: ...o it beeps faster during the last ten seconds As shown to the right a bar appears at the base of the display This bar represents the amount of time you have to enter the building and disarm the sys tem When half of the time has expired the bar is half its original length Disarming To Disarm the System 1 Enter through a door pro grammed with an entry delay 2 Enter your user code Regardless of which...

Страница 34: ... SMTWTFS 3 In this example the boxes show disarming occurs on weekdays Press the number above the letter of the day s you wish to switch on or off 4 To exit press the key Your system can automatically disarm itself at preset times of the day This option must be programmed into your system by your installer You can change the days of the week that Automatic Disarming occurs by following the proce d...

Страница 35: ...arm You can cancel the alarms of any sensor includ ing a smoke detector The amount of time you have to cancel the alarm depends upon how your installer pro grammed the system See the Cancel Alarm Time listing in Section 8 Five seconds after an alarm is canceled your system reverts to normal After an Alarm You should reset your system after an alarm This action clears your keypad s display and rese...

Страница 36: ...your keys are 4 Shut doors and windows completely Before arming your system be sure all protected windows and doors are closed As you leave the building shut the exit door com pletely 5 Regularly test and maintain your system Routine testing and maintenance will help you detect a service con dition See Section 6 for more information 6 Be selective when arming the system for instant alarms This set...

Страница 37: ...ypassed zones are not protected Optional Alarm Features Your system offers the optional alarm features described below Refer to Section 8 to see if these options are installed on your system Alarm Lockout The system automatically ignores a sensor that repeatedly sends alarm signals Silent alarm With this option no bells or sirens sound during an alarm but the monitoring station is notified If the ...

Страница 38: ... m You see am Byp OK Home CHG 5 If the time is correct press the key If the time is not correct press the How to Set the Clock and Calendar If your system s clock and cal endar is incorrect it could re sult in false alarms Since many system functions are time dependent it is very im portant to regularly check your system s clock and cal endar Be sure to reset the clock after seasonal time changes ...

Страница 39: ...something like this 24 NOV 1998 Byp OK Home CHG To change the date press the key You see day month year 00 00 00 7 Enter the correct date using two numbers each for the day month and year You see something like this 10 JAN 1999 Byp OK Home CHG 8 Press the key if the date is correct if not press the key www ukpanels com ...

Страница 40: ...turns it off If the tone is off the action turns it on To Turn Tone On Off 1 Press and hold the pre warn key for 2 seconds until you hear two beeps When prompted enter the master user code If the tone is on you see PREWARN ON Byp OK Home CHG 2 To turn the leave the tone on press the key To turn it off press the key If you made no changes your system returns to normal au tomatically If you turned t...

Страница 41: ...em off How to Turn the Chimes On Off To Turn Chime On Off 1 Press and hold the chime key for 2 seconds until you hear two beeps When prompted enter the master user code If the chime is on you see CHIME ON Byp OK Home CHG 2 To turn leave the chime on press the key To turn it off press the key If you made no changes your system returns to normal au tomatically If you turned the chime on or off press...

Страница 42: ...hen the key pad is in use press the key 4 To exit press the key Whenever you use your key pad a light automatically illu minates the display and keys This backlight shuts off 60 sec onds after you have finished us ing the keypad If you wish you can set the backlight to shine continuously This makes it easier for you to notice system messages espe cially if your keypad is located in a dark area If ...

Страница 43: ...the business upcoming holi day You can change the days that the relay works by following the procedure to the right To change the time of day that the relay works contact your in staller To Change the Relay Days 1 Press and hold the walk test key for 2 seconds until you hear two beeps When prompted enter the master user code Then press the key until you see RELAY SCHEDULE Byp NO Home Yes 2 On your...

Страница 44: ...lk test mode and make sure the sensor s zone is not bypassed If it is bypassed remove the bypass and repeat the walk test If this does not correct the problem contact your service represen tative Important during a walk test your building is not protected against actual alarms To Conduct a Walk Test 1 Press and hold the walk test key for 2 seconds until you hear two beeps When prompted enter the m...

Страница 45: ... next event or to Your system records important events in Event Memory You can review Event Memory to monitor the status of your sys tem Alarms trouble indicators changed user codes and bat tery failures are some of the events recorded in Event Memory Your system can store at least 60 events but may store as many as 500 Times are recorded in a 24 hour format To convert from 24 hour time to 12 hour...

Страница 46: ... 2 Press the key twice You see AUDIBLE TEST Byp NO Home YES 3 Press the key Your system s bells or sirens ring for 4 seconds 4 To exit press the key You can test your system s bells and sirens by following the pro cedure to the right See Note 2 on page 64 Event Memory cont d view the previous event 4 To exit press the key Event Memory continued www ukpanels com ...

Страница 47: ...ystem At your monitoring station s prompting you can initiate a re mote programming session by following the directions to the right To Start A Remote Programing Session 1 Press and hold the walk test key for 2 seconds until you hear two beeps When prompted enter your user code 2 Press the key three times You see RPS CALLBACK Byp NO Home YES 3 Press the key The remote programming session begins No...

Страница 48: ...ions in Trouble shooting Service Conditions later in this section To replace your system s bat tery call your service represen tative See Note 2 on page 64 To Test the Battery 1 Press and hold the walk test key for 2 seconds until you hear two beeps When prompted enter your user code 2 Press the key four times You see BATTERY TEST Byp NO Home YES 3 Press the key The battery test begins To clear th...

Страница 49: ...e and zone 32 is by passed Periods mean no problems exist with zones 2 8 and 10 31 2 To exit press the key You can rapidly review the sta tus of your system by using Quick View Quick View will tell you for example if any zones have been faulted or bypassed Quick View uses the following abbreviations to summarize a zone s status B Bypass The zone is bypassed F Faulted The zone s sensor is faulted T...

Страница 50: ...ne is faulted Correct the fault by Faulted cannot fully arm closing doors windows or bypass the zone Display reads A sensor needs Bypass the sensor or Trouble service arrange for repair Display reads A sensor may have Call for service Tamper been tampered with Display repeatedly A sensor may need Call for service reads Trouble service Tamper Display reads Any one of your Depending upon your Ready ...

Страница 51: ... of action listed in the table To stop the service message warning tone enter your user code between the two beeps When done press to exit What to do Meaning Message AC POWER LOSS BROWN OUT PANEL LOW BATT GROUND FAULT There is a power failure in progress A power loss short of total failure has occurred The control panel s battery is low Power from the system has short circuited to the ground wire ...

Страница 52: ...If not call telephone company for service If line is functioning call monitoring sta ion If not call telephone company for service Call for service Call for service Call for service Call for service Call for service Call for service Call for service The monitoring station phone 1 does not answer The monitoring station phone 2 does not answer There are too many messages to send to he monitoring sta...

Страница 53: ...ommon area an area most system us ers can arm and disarm The first diagram shows how a building could be divided to in clude a common area Buildings may also be parti tioned without a common area As the second diagram shows this setup works well for struc tures with tenant spaces but no lobby or shared hallway Each system user is assigned rights to one or more areas Users can arm and disarm only t...

Страница 54: ... restaurant can remain open af ter the other shops are closed and armed Dividing a building into areas changes the following system functions 1 Users have restricted ac cess to system functions A user with access to only one area cannot issue commands affecting other areas or obtain information about the other ar eas 2 Keypads may respond dif ferently depending upon where they are located and how ...

Страница 55: ...er Code Area basic users can dis arm and may be able to arm bypass or make other changes within an area Users can have rights to more than one area Area Maid Code Maid Days are assigned to each area so if you need to change the Maid Days you must make the changes for each area individually Kidwatch Code Your system recognizes only one Kidwatch Code regardless of how many areas are present The Kidw...

Страница 56: ...he remaining areas do not apply No Reserved User 01 Grand Master User 11 Kidwatch 12 Area 1 Master 13 Area 1 Maid 15 Area 1 Duress 16 Area 2 Master 17 Area 2 Maid 19 Area 2 Duress 20 Area 3 Master 21 Area 3 Maid 23 Area 3 Duress 24 Area 4 Master 25 Area 4 Maid No Reserved User 27 Area 4 Duress 28 Area 5 Master 29 Area 5 Maid 31 Area 5 Duress 32 Area 6 Master 33 Area 6 Maid 35 Area 6 Duress 36 Area...

Страница 57: ...he menu s display see below The table on the following page explains the abbreviations used in the Area Status menu Thus in the example above area 1 is ready to be armed while area 3 is armed To get more information about any given area press and hold the quick view key for two seconds until you hear two beeps Then press the area number This takes you to the Quick View display described later in t...

Страница 58: ...s being armed with home arming An exit delay is in progress I steadily lit The area is armed with instant arming N steadily lit The area is not ready to be armed R steadily lit The area is ready to be armed R blinking The area is being disarmed An entry delay is in progress Area No The area is or was in alarm blinking Word Area Enter the area number to be armed disarmed etc is blinking The Area St...

Страница 59: ...case you must correct or bypass any trouble or faulted zones before arming can take place To Arm One Area 1 Enter your user code You see something like this AREA 12345678 STATUS RNAHIRAH 2 To arm an area using full arm ing press that area number 3 To arm an area using home arming press the key followed by the area number 4 To arm an area using instant home arming press and hold the instant key for...

Страница 60: ... is already armed it will not be affected by a command to arm all areas Thus for example if Area 4 is armed with home arming and a command is issued to arm all areas with full arming Area 4 will remain armed with home arming Arming Multiple Areas To Arm All Areas 1 Enter your user code You see something like this AREA 12345678 STATUS RNAHIRAH 2 To arm all of your assigned areas using full arming p...

Страница 61: ...ething like this AREA 12345678 STATUS RNAHIRAH 2 To disarm an armed area press that area number Disarming Individual Areas Disarming Multiple Areas From the Area Status Menu you can enter one command which instructs your system to disarm all of the areas to which you have rights To Disarm All Areas 1 Enter your user code You see something like this AREA 12345678 STATUS RNAHIRAH 2 To disarm all of ...

Страница 62: ...the key fol lowed by the two digit zone number 3 To remove the bypass on a zone press the key followed by the zone number 4 To exit press the key twice The Zone Status Menu tells you if the zones of an areas are nor mal faulted or bypassed De pending on your system s pro gramming you may only be able to view the Zone Status Menu for those areas to which you have rights The Zone Status Menu uses th...

Страница 63: ...n a given area that area num ber in the Area Status Menu blinks You can reset the dis play by following the instruc tions to the right Canceling Alarms In a partitioned system you can have simultaneous alarms in several areas For example at the same time alarms may occur in areas 2 3 and 5 To cancel an alarm in an area press the key and enter your user code You must have rights to an area to cance...

Страница 64: ...ns Check if installed _____Maid Code _____Kidwatch Code _____Duress Code _____Automatic Timed Arming _____Automatic Disarming _____Home Arming _____Quick Home Arming _____Quick Full Arming _____Automatic Home Arming _____Instant Home Arming _____Quick Instant Home Arming _____Force Arming _____Goof Proof Arming _____Chirp Alert Arming _____Quick Bypassing _____Quick Exit _____Exit Termination ____...

Страница 65: ...ime _____________________________ Automatic Disarming Time ___________________________ Device Connected to Relay 1 _________________________ Relay 1 Start Time _________________________________ Device Connected to Relay 2 _________________________ Relay 2 Start Time _________________________________ Device Connected to Relay 3 _________________________ Relay 3 Start Time __________________________...

Страница 66: ...62 8 Notes Below is a space to sketch how the building is zoned and or divided into areas Be sure to note how the zones and or areas are numbered and labeled Sketch www ukpanels com ...

Страница 67: ...ensors both along the building s perimeter and in side the building Home Arming a method of arming that arms only those sensors along the pe rimeter of your building Instant Arming a method of arming that triggers an alarm the instant a sen sor detects an alarm condition Monitoring Station a service that monitors the status of your security sys tem through a telephone hook up Tamper describes a se...

Страница 68: ...ual may not be avail able due to U L or local requirements Contact your in stallation company for further information 2 These tests should be conducted on a weekly basis Con tact your installation company for your particular require ments www ukpanels com ...

Страница 69: ...near the bedrooms In new construction a smoke detector must be installed in each bedroom Smoke detectors should also be installed in living rooms closets utility and storage rooms basements and attached garages One detector should be placed on every floor For more information contact the National Fire Protection Associa tion at Batterymarch Park Quincy MA 02269 Ask about Standard 72 Chapter 2 BEDR...

Страница 70: ...ou take the following steps to develop your own emergency plan 1 Determine at least two means of escape from every room especially bedrooms Remember that normal exits such as doors may be blocked Plan for family members to meet outside at a specific location 2 Sketch your escape plans like those below Post copies of the escape plan in each room Keep escape routes free from obstruc tions 3 Keep all...

Страница 71: ...ency keys 4 5 Entry delay 29 Event Memory 41 Exit delay 19 Exit termination 27 Extended exit delay 27 False alarms preventing 32 Glossary 63 Keyfob deleting lost 10 Keypad lockout 27 Keyswitch arming 27 Kidwatch Days 12 Learning period 3 Maid Days 14 RPS session 43 Relay days changing 39 Remote deleting lost 10 Remote Programming Session 43 Secondary Function Keys 4 Service conditions 47 Siren tes...

Страница 72: ...ttp www cksys com Copyright 1998 C K Systems Inc 5 051 530 01 Rev B For service on this system contact Company ________________________________ Address ________________________________ ________________________________ Telephone ________________________________ ________________________________ www ukpanels com ...