Rev 3.2 Oct.05
71
+CGQMIN
(continued)
Set or query minimum acceptable quality of service (continued)
•
<precedence>
Specifies the precedence class where 0=subscribed,
1=high, 2=medium, and 3=low.
•
<delay>
is a numeric parameter which specifies the delay class
where 0=subscribed, 1=low, 2=medium, 3=high, and
4=best effort.
•
<reliability>
Specifies the reliability class where 0=subscribed
(default), 1=acknowledged, 2=frame acknowledged,
3=block mode acknowledged, 4=data protected,
5=unprotected.
•
<peak>
Specifies the peak throughput class where 0=subscribed
(default), 1=up to 8 kbps, 2=up to 16 kbps, 3=up to
32 kbps, 4=up to 64 kbps, 5=up to 128 kbps, 6=up to
256 kbps, 7=up to 512 kbps, 8=up to 1024 kbps, 9=up to
2048 kbps.
•
<mean>
Specifies the mean throughput class where
0=subscribed, 1=up to ~ 0.22 bps, 2=up to ~ 0.44 bps,
3=up to ~ 1.11 bps, 4=up to ~ 2.2 bps, 5=up to ~ 4.4 bps,
6=up to ~ 11.1 bps, 7=up to ~ 22 bps, 8=up to ~ 44 bps,
9=up to ~ 111 bps, 10=up to ~ 0.22 kbps, 11=up to
~ 0.44 kbps, 12=up to ~ 1.11 kbps, 13=up to ~ 2.2 kbps,
14=up to ~ 4.4 kbps, 15=up to ~ 11.1 kbps, 16=up to
~ 22 kbps, 17=up to ~ 44 kbps, 18=up to ~ 111 kbps,
19=best effort (default).
+CGQREQ
[=<cid>]
[,<precedence >]
[,<delay>]
[,<reliability>]
[,<peak>]
[,<mean>]
+CGQREQ?
+CGQREQ=?
Request specified (or query current) quality of service profile
Note: If you are using an AirCard 775, use the cCGEQREQ
described on page 68, rather than this command.
Specifies a Quality of Service Profile to be used when the modem sends an
Activate PDP Context Request message to the network. If the specified profile
is unavailable, the modem returns an error.
Note: The
D**##
command (used to establish GPRS connections) uses only
those settings assigned to the PDP Context Identifier 1 (that is, <cid>=1).
All parameters are as outlined in
+CGQMIN
(page 70).
Note: To specify a minimum acceptable QoS profile, use the
+CGQMIN
command (page 70).
Table 3-9: Command Reference Table (ASCII Alphabetic)
Command
Description
Содержание MP 700 Series
Страница 1: ...MP 700 Series GPS Rugged Wireless Modem AT Command Reference 2130309 Rev 3 2...
Страница 2: ......
Страница 6: ...MP 700 Series GPS AT Command Reference 4 2130309...
Страница 24: ...MP 700 Series GPS AT Command Reference 22 2130309...
Страница 116: ...Index Rev 3 2 Oct 05 114...
Страница 117: ......
Страница 118: ......