WA_DEV_SL6087_PTS_002
Rev 001
Jun 17, 2010
12
3. Technical Specifications
3.1.
Power Supply
The following table describes the electrical characteristics of the input power supply voltage that will
guarantee nominal functioning of the AirPrime SL6087 Embedded Module.
Table 2:
Input Power Supply Voltage
V
MIN
V
NOM
V
MAX
Ripple Max (U
ripp
)
I
peak
Max
VBATT
3.2V
1,2
3.6V
4.8V
250mVpp (freq < 10kHz)
40mVpp (10kHz < freq <
100kHz)
5mVpp (freq > 100kHz)
(TBC)
2.0A
1: This value must be guaranteed during the burst (with 2.0A Peak in GSM, GPRS or EGPRS mode)
2: Maximum operating Voltage Standing Wave Ratio (VSWR) 2:1.
3.2.
Mechanical Specifications
The AirPrime SL6087 Embedded Module has a nearly-complete self-contained shield. The
mechanical specifications are shown in the figures below, including the area needed for the AirPrime
SL6087 Embedded Module to fit in an application.