41110590
Rev 6.1
January 28, 2019
34
Product Technical Specification and
User Guide
Last Gasp Configuration
+LASTGASP Command: Last Gasp Status
Reference
Sierra Wireless
Proprietary
Command
Notes
•
Last computed supercap will always be 0.0 since it is not available.
•
If
AT+LASTGASP=1
is entered and power failure is detected, the device shuts
down right after the predefined SMS or UDP has been sent, which can take some
time depending on network conditions.
•
+KSIMSEL
is deactivated when Last Gasp is active since they are mutually
exclusive.
+KSIMSEL
returns
+CME ERROR: 4
when Last Gasp is active.
Examples
AT+LASTGASP?
+LASTGASP: GL7600.2.23.172400.201706231140.x7120m_1,3.95,12.00,0.0,1,1,1
OK
Here, the parameters are:
Firmware version: GL7600.2.23.172400.201706231140.x7120m_1
Super capacitor voltage: 3.95 V
Supply voltage: 12.00 V
Last computed supercap: 0.0
Last gasp response status: 1 (active)
SMS response status: 1 (active)
UDP response status: 1 (active)
AT+LASTGASP=?
+LASTGASP: (0,1)
OK
AT+KSIMSEL=?
+CME ERROR: 4
5.2.
+LASTGASPSMS Command: Last Gasp
Configuration Command for SMS Content
+LASTGASPSMS Command: Last Gasp Configuration Command for SMS Content
Test command
Syntax
AT+
LASTGASPSMS
=?
Response
+LASTGASPSMS: <da>
,
<msg>
OK
Read command
Syntax
AT+
LASTGASPSMS?
Response
If configuration is not empty:
+LASTGASPSMS: <da>
,
<msg>
OK
If configuration is empty:
+LASTGASPSMS: ""