7.1 Standard Specifications
1st edition : Aug. 2006
Rev. A: May. 2007
7-1
Chapter 7 Documents
7.1 Standard Specifications
Table 7-1 Standard Specifications (1/2)
Item
HRG010-W
HRG015-W
Rated ambient temp.
32
°
C (5 to 40
°
C)
In
st
alla
tio
n
Operat
ing
env
ironm
ent
Humidity range
45 to 75%RH (No condensation)
Fluid used
Circulating fluid/fresh water (tap water) or fluids resistant to corrosion of a wetted surface
(such as SUS304 and PVC)
Rated capacity of tank
40L
50L
Supply voltage
3-phase AC200(50Hz), AC200 to 220V (60Hz)
Recommended earth
leakage breaker capacity,
Sensitivity current
40A, 30mA
60A, 30mA
Rated power consumption
3.2/3.8 - 3.8 kW
4.7/5.8 - 5.8 kW
Rated operating current
12.0/12.5 - 12.5A
18.0/19.0 – 19.0A
Rated consumption
electric energy
3.2/3.8 - 3.8 kWh/h
4.7/5.8 - 5.8kWh/h
Facility water
Supply temp.: 25°C (5 to 32°C),
Flow rate: Max. 33/34L/min,
IN/OUT differential pressure: Max.
0.25/0.2MPa,
Max. supply press.: 0.3 to 0.4MPa, Exhaust
heat: Approx. 16W
Supply temp.: 25°C (5 to 32°C),
Flow rate: Max. 38/40L/min,
IN/OUT differential pressure: Max. 0.25/0.2MPa,
Max. supply press.: 0.3 to 0.4MPa, Exhaust heat:
Approx. 23W
Input
Start/stop command
signal
Remote operation starts upon application of DC24V and 8 mA, and stops at DC0V.
Rated temp. / accuracy of
circulating fluid
20±1.0°C (only under given load condition)
Temp. range of circulating
fluid
5 to 35
°
C
Rated cooling capacity
10.0/11.0 kW
(50/60 Hz, 20
°
C at outlet, 37/49L/min of flow)
14.5/16.5kW
(50/60 Hz, 20
°
C at outlet, 42/54L/min of flow)
Rated heating capacity
- (1.1kW of pump motor output only)
- (0.75kW of pump motor output only)
Pumping capacity
Max. head: 50/50m (50/60Hz, 0/0L/min of flow, 0.49/0.49MPa of supply pressure)
Rated flow
37/49L/min
(50/60Hz, 25/25m of the max. head,
0.29/0.33MPa of supply pressure)
42/54L/min
(50/60Hz, 25/25m of the max. head,
0.28/0.31MPa of supply pressure)
Max. flow rate
48/60L/min
(50/60Hz, 0/0m of the max. head,
0.08/0.12MPa of supply pressure)
54/65L/min
(50/60Hz, 0/0m of the max. head,
0.05/0.09MPa of supply pressure)
Op. signal
Relay contact ( AC250V of contact capacity, 1A, resistance load. Contact closes during operation,
and contact opens during stop and during power-off.)
Out
put
Output
signal Emergency stop
signal
Relay contact (AC250V of contact capacity, 1A, resistance load. Contact closes while alarm light
remains OFF and during power-off, and contact opens while alarm light remains ON.)
Temperature control
Combined use of temperature control through compressor operation (ON/OFF) and capacity
control through solenoid valve control (ON/OFF)
Operation panel
7segment digital display, capable of display in 0.1
°
C increments
PV (operating temp.): 4-digit display in green, SV (set temp.): 4-digit display in red
Other display lamps: ALARM1 to 3 individual display in the event of an error)
Refrigerant high pressure
gauge
Range: -0.1 to 3.5 MPa
Refrigerant pressure
gauge
Range: 0 to 1.0 MPa
D
isp
la
y
Level indicator
SMC Ø-10 tube TU1065C (transparent)