3/. Remove glass or logs from burner / Retirer le verre ou des billes de brûleur
4/. Remove the burner pan / Retirer la casserole du brûleur
5/. Undo the set screw on the air shutter and adjust accordingly then retighten the set screw. / Défaire la
vis de réglage sur le volet d'air et d'ajuster en conséquence, puis resserrez la vis de
réglage.
6/. Reassemble the fireplace in reverse order from 4 through 2. / Remonter la cheminée dans l'ordre
inverse de 4 à 2.
7/. Turn on the gas. / Allumez le gaz.
Factory Setting
Natural Gas – open 1/8” (3.175mm)
Propane Gas – open 1/2” (12.7mm)
Aeration adjustment is important for the correct functioning of the appliance. Carbon build up, flame
lifting or any malfunction due to improper aeration adjustment during installation is not covered under
the factory warranty.
Réglage de l'aération est importante pour le fonctionnement correct de l'appareil. Une accumulation
de carbone, de levage flammes ou de toute défaillance due à une mauvaise aération d'ajustement
lors de l'installation n'est pas couvert par la garantie d'usine.
3.3.10 ALTITUDE ADJUSTMENT
Altitude
Natural Gas –
Orifice Size
Propane Gas –
Orifice Size
0 – 4500 ft (0 – 1372 m)
41
54
4500 – 6500 ft (1372 - 1981 m)
42
55
6500 - 8500 ft (1981 - 2591 m)
43
56
All valves have been pre-set and certified for installation at elevations from 0 – 4500 feet (0-1372m)
above sea level. Certified to CSA 2.17-M91 – gas fired appliances for use at high altitudes.
When installing this unit at higher elevations, it is necessary to decrease the input rating by replacing
the existing burner orifice with a smaller size for installations over 4500 feet (1372m). For the USA,
de-rate the unit from sea level according to the gas installation code.
CAUTION
ATTENTION
PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT.
PIECES NECESSITANT REGLAGE PENDANT LA MARCHE PEUT ETRE CHAUDE
Air tube and Air shutter shown removed
for clarity purposes only.
Set Screw
Содержание THOMPSON-36-DELUXE-LP
Страница 25: ...Page 25 of 57 34 20 A A B B Example Where A A Vertical 2 And B B Horizontal 5 12 MINIMUM 12 MAXIMUM...
Страница 50: ...Page 50 of 57 8 0 LABEL INFORMATION...
Страница 52: ...Page 52 of 57 APPENDIX A AMERICAN FLAME VALVE INFORMATION...
Страница 53: ...Page 53 of 57 APPENDIX A Continued...