Troubleshooting
en
45
Fault
Cause and troubleshooting
"E:30 / -80"
Unapproved extension installed on the water drain
hose.
▶
Remove any unapproved extensions from the water
hose.
→
"Connecting the appliance", Page 14
The pump cap is not fully screwed in.
▶
Ensure that the pump cap is screwed in all the way
into the appliance. The handle on the pump cap
must be in a vertical position.
"E:36 / -25 / -26"
Drain pump is blocked.
▶
"Cleaning the drain pump", Page 41
"E:38 / -25 / -26"
Drain pump is blocked.
▶
if the fault is displayed again,
▶
"Cleaning the drain pump", Page 41
Inlet opening of the rubber gasket is blocked.
▶
"Cleaning the intake opening in the rubber gas-
i-DOS error, deactiv-
ate i-DOS
The pump for the intelligent dosing system is blocked.
1.
Switch off the appliance.
2.
Clean the pump unit.
→
"Cleaning the detergent drawer", Page 39
3.
Switch the appliance on.
4.
If the display appears again after you clean the
pump unit, call customer service.
→
Note:
You can deactivate and manually dose the intel-
ligent dosing system until the fault is rectified.
→
"E:30 / -10" and/or
The filter in the water inflow is blocked.
▶
Clean the water inflow filter.
The tap is turned off.
▶
Turn on the tap.
The water inlet hose is kinked or jammed.
▶
Ensure that the water inlet hose is not kinked or
jammed.
All other error codes.
Malfunction
▶
Call the after-sales service.
→
Содержание WM14VE00CS
Страница 59: ......