Ultraheat / Ultracold UH50 

 

Configuration Instructions 

UH 106-101k 

Page 14 / 15 

Display: MWh with 3 decimal places (as of qp 15 with 
2 decimal places) 

Display: MJ (until qp 3) 

Display: GJ with 3 decimal places (as of qp 3.5 with 2 
decimal places) 

Display: kWh (until qp 10), flashing 

Display: MWh with 3 decimal places (as of qp 15 with 
2 decimal places), flashinh 

Display: GJ with 3 decimal places (as of qp 6 with 2 
decimal places), flashing 

Display: m³ (for the flow meter) with 2 decimal places 
(as of qp 40 with 1 decimal place) 

 

 

Further features 

Measurement dynamics 

Code 

Dynamic range 1:100 

other ranges on request 

 

 

 

Modules as accessories 

Power supply modules 

Code 

Power supply 110V AC with 10m cable 

WZU-AC110-100 

Power supply 110V AC with 1.5m cable 

WZU-AC110-15 

Power supply 110V AC with 5m cable 

WZU-AC110-50 

Power supply 230V AC with 10m cable 

WZU-AC230-100 

Power supply 230V AC with 1.5m cable 

WZU-AC230-15 

Power supply 230V AC with 5m cable 

WZU-AC230-50 

Power supply 24V AC/DC with plug 

WZU-ACDC24-00 

Power pack 230 V AC for analog 
module WZU-AM

 

WZR-NE

 

Communication modules 

Code 

Analog module 

WZU-AM 

CL-Module 

WZU-CL 

M-Bus module acc. to DIN 1434-3 (G2-
generation 2 – recommended until 
meter FW 5.14) 

WZU-MB 

M-bus module (G2) with 30s minimum 
reading cycle 

WZU-MB-30 

M-bus module (G2) with guaranteed 
data set 

WZU-MB-GR 

M-Bus module G4 acc. to EN 13757 and 
DIN 1434-3 (G4 - Generation 4 - FW 
5.15 and higher) 

WZU-MB-G4 

M-Bus module G4 acc. to EN 13757 and 
DIN 1434-3 (G4 - Generation 4 - FW 
5.15 and higher) with 2 pulse inputs 

WZU-MI 

Pulse module 

WZU-P2 

Pulse module with OptoMOS 

WZU-P2L 

GSM Module with 2 pulse inputs, with 
battery; SMS support 

WZU-GM 

GPRS module with ext. antenna 
(magnetic attachment) and UH50 power 
pack 110..230V / cable 5m; with 
interface for up to 8 M-Bus 
meter to be read over GPRS; amongst 
others Email support 

WZU-GPRS 

Radio module 

WZU-RM 

Radio module with external antenna 

WZU-RM-EXT 

For mounting of temperature 
sensors 

Code 

Adapter for ball valves to install temp-
erature sensors DS length 38 mm

 

WZT-KA 

Mounting accessories for tubes

 

Code

 

Kit extension from 110 mm G ¾B to 
130 mm G 3/4 B (with seals) 

WZM-V130 

Kit extension from 110 mm G ¾B to 
190 mm G 1 B (in pairs with seals) 

WZM-V190 

Spacer for heat meter DN 100 - 360 
mm PN 16, incl. sealing disks 

WZM-F360.100-16 

Spacer for heat meter DN 100 - 360 
mm PN 25, incl. sealing disks 

WZM-F360.100-25 

Notes 

  All  regulations  on  the  use  of  meters  must  be 

observed. 

  Cavitation in the system must be avoided. 

  Meters  up  to  DN25  may  only  be  installed  with 

directly  immersed  sensors  according  to  German 
calibration law! 

  Install  the  unit  in  such  a  way  that  no  water  can 

enter the electronic unit during operation. 

  User  seals  may  only  be  removed  by  authorized 

persons  for  service  purposes  and  must  be 
replaced afterwards.  

  The  unit  is  supplied  with  Installation  and  Service 

Instructions and with Operating Instructions. 

  No  later  than  30 seconds  after  installation,  the 

meter  detects  the  plugged  modules  automatically 
and is ready for communication or pulse output.  

  The  type  of  modules  plugged can be displayed in 

the  service  loop  depending  on  how  the  display  is 
parameterized. 

  For  fast  pulses,  the  parameters  must  be  set 

accordingly with the service software. 

  Up-to-date  versions  of  all  instructions  can  be 

found in the Internet at 

www.siemens.com/sbt

 

 
 

Siemens AG 

Building Technologies 

 

Please contact our next sales office 

Содержание UH50 FLOW SENSOR

Страница 1: ...prior notice UH 106 101k Page 1 15 Static Heat and Cold Meter UH50 issue January 2010 Configuration Instructions UH 106 101k Static meter for Heating and Cooling systems UH50 ULTRAHEAT UH50 ULTRACOLD UH50 FLOW SENSOR Version of firmware 5 15 and higher ...

Страница 2: ...l voids the warranty The 110 V 230 V versions must only be connected by an electrician The lithium batteries must be properly returned Lightning protection cannot be ensured this must be provided by the building wiring Only one compartment for the power supply must be equipped do not remove the red locking hatch General information The UH50 meter is used for energy consumption metering in short an...

Страница 3: ... 6 10 G 2 20 100 40 300 1 5 190 3 5 260 7 35 14 60 14 4 5 1 5 190 2 5 G 1 5 25 10 200 5 6 1 8 0 5 190 1 5 3 15 6 1 2 G 1 160 3 8 0 6 1 2 6 2 4 150 1 5 14 4 5 G 1 260 12 60 24 180 Tolerance pressure lost 5 Small meters qp 0 6 2 5 m h Overall length 110 mm thread Overall length 130 mm thread Overall length 190 mm thread Overall length 190 mm flange Large meters with threaded joint qp m h PN bar a b ...

Страница 4: ... removable control cable may be separated during the installation When installation is done be sure that only paired parts volume part calculator are connected together Ball valve Example of mounting with a ball valve recommended up to DN25 Welded sleeve with pocket Example of mounting with pockets recommended above DN25 Mounting as a cold meter When mounting a cold meter or combined heat cold met...

Страница 5: ...ction of service loops LOOP 1 n Service loop selection Service loop 1 Service loop 2 LOOP n Service loop n LCD button 1 advances the display to the next loop After the last loop the user loop LOOP 0 appears again LCD button 2 displays the content of the selected service loop Within a loop the LCD button 2 is used to advance to the next line of the display After the last line of the display the fir...

Страница 6: ... flow temperature and return temperature with their date stamp for up to 60 months on the set day of each month Note The standard time used is Central European Time CET If daylight saving time is activated storage will be performed accordingly The monthly values can also be read out via the optical and the 20 mA interface Resolution of the display kWh MWh MJ GJ m Places after decimal point blinkin...

Страница 7: ... rigid or flexible 0 2 2 5 mm flexible with end ferrules 0 25 1 5 mm conductor sizes 26 14 AWG Multiple conductor connection 2 conductors of same cross section rigid or flexible 0 2 0 75 mm flexible with end ferrules without plastic sleeve 0 25 0 34 mm flexible with TWIN ferrules with plastic sleeve 0 5 0 75 mm Recommended screwdriver 0 6 x 3 5 mm Tightening torque 0 4 Nm Permissible combinations ...

Страница 8: ...d version A special version of the pulse module is available with an Opto MOS output Advantages low voltage drop and polarized bipolar Standard pulses Standard pulse significances kWh MJ m 10 15 25 40 2 5 3 5 60 Nom flowrate in m h 10 MJ 0 6 1 kWh 10 kWh 1 m 0 1 m 100 MJ 1 MJ depending on the unit for heat display Pulses for quantity of energy volume tariff register Period duration 200 ms Pulse du...

Страница 9: ...The analog module converts a selectable measured value of the meter into an analog output signal 2 output signals channel 1 channel 2 The following measured values can be selected power Flowrate Flow temperature Return temperature Temperature difference The following can be selected as the output signal 0 20 mA 4 20 mA 0 10 V Radio module Display on LCD RM radio module Please read the appropriate ...

Страница 10: ...ature from the defined return temperature threshold instead of from the temperature difference Above return threshold T1 is summated Below return threshold T2 is summated Display of the tariff situation on the LCD The current tariff status is shown in the user loop together with the quantity of energy or the volume No tariff status is shown for tariffs T7 and T8 for tariffs T2 T3 T4 T5 T6 T10 T11 ...

Страница 11: ... 20 Monthly set day parameterized 21 Master reset performed 22 All times deleted 23 Missing time deleted 24 Event occurs Maxima deleted Read out is performed via the optical interface with the service software Data logger optional The data logger permits the archiving of data that the user can select from a predefined set of values The data logger contains four archives whose 8 channels can be ass...

Страница 12: ... 5 m h length 110mm nominal pressure PN25 connection G B 22 Nominal flowrate 1 5 m h length 190mm nominal pressure PN16 connection G 1 B 23 Nominal flowrate 1 5 m h length 190mm nominal pressure PN25 connection flanged DN 20 24 Nominal flowrate 1 5 m h length 190mm nominal pressure PN25 connection G 1 B 25 Nominal flowrate 1 5 m h length 130mm nominal pressure PN16 connection G 1 26 Nominal flowra...

Страница 13: ...r Pt500 removable mounting in the tube as an option G Sensor Pt500 removable mounted in the tube within a pocket H Sensor Pt100 not removable not mounted in the tube N Sensor Pt100 not removable mounted in the tube P Sensor Pt100 not removable mounting in the tube as an option R Sensor Pt100 not removable mounted in the tube within a pocket S Hardware dependent features 7 Sensor type Code Without ...

Страница 14: ...GSM Module with 2 pulse inputs with battery SMS support WZU GM GPRS module with ext antenna magnetic attachment and UH50 power pack 110 230V cable 5m with interface for up to 8 M Bus meter to be read over GPRS amongst others Email support WZU GPRS Radio module WZU RM Radio module with external antenna WZU RM EXT For mounting of temperature sensors Code Adapter for ball valves to install temp eratu...

Страница 15: ...Ultraheat Ultracold UH50 Configuration Instructions UH 106 101k Page 15 15 ...

Отзывы: