Table of Contents
1 General Information
4
1.1 Parts Illustrations
4-5
2 Receiving And Handling
6
2.1 Receiving
6
2.2 Handling
6
2.3 Skid Removal
8
2.4 Storage
8
3 Installation
9
3.1 Installation Quick Check List
9
3.2 Operating Environment
10
3.3 Site Preparation
10
3.4 Mounting
11
3.5 Top And Bottom Covers
12
3.6 Installation Of Seismic Qualified Structures
13
3.7 Joining Shipping Sections
13
3.8 Ground Bus
13
3.9 Splice Kits
15
3.10 Pull Box Installation
16
3.11 Incoming Power Connections
16
3.12 Incoming Line Termination Arrangements, Main Lugs
18-19
3.13 Incoming Line Termination Arrangements, Main Circuit Breakers
20-21
3.14 Incoming Line Termination Arrangements, Main Fusible Switches
22-23
3.15 Load And Control Wiring
24
3.16 Field Additions
25
3.17 Plug-in Unit Removal
25
3.18 Plug-in Unit Addition
26
3.19 High Density Unit Installation
27
3.20 Insulation (Megger) Test
28
4 Operation
29
4.1 Pre-Energization Checks
29
4.2 Energizing Equipment
30
4.3 Permissible Loading Of Motor Control Centers
30
5 Maintenance
31
5.1 Maintenance Quick Check
31
5.2 General Inspection Of The MCC
32
5.3 Periodic Cleaning
33
5.4 Stab Fingers And Vertical Bus
33
5.5 Recommended Tightening Torques
33
5.6 Disconnect Operating Handle Adjustment
34
5.7 Adjustment Notes
35
5.8 Maintenance After A Fault Has Occurred
35
5.9 Disconnecting Means
35
5.10 Terminals And Internal Conductors
36
5.11 Adjustment Of SentronTM Type ETI
Instantaneous Trip Motor Circuit Interrupter (1A-125A)
37
5.12 Field Testing Of The Circuit Breakers
37
5.13 Overload Relay
37
6 Troubleshooting
38-40
7 HeaterTables
41
IMPORTANT
These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be
met in connection with installation, operation or maintenance. Should further information be desired or should particular problems
arise which are not covered sufficiently for the purchaser.s purposes, the matter should be referred to the local Siemens sales office.
The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or rela-
tionship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is
the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty.
Siemens Energy & Automation, Inc.
3
Содержание TIASTAR
Страница 1: ...TIASTAR Motor Control Center Instruction Guide SFIS 70060 0509 May 2009 ...
Страница 14: ...Figure 11 Siemens Energy Automation Inc 14 ...
Страница 17: ...Siemens Energy Automation Inc 17 Figure 15 ...
Страница 43: ...Siemens Energy Automation Inc 43 ...
Страница 44: ...Siemens Energy Automation Inc www sea siemens com Publication No SFIS 70060 0509 Printed in the USA ...