37
en
Problem
Cause
Remedy
LED
D
flashes.
The water tank is not
correctly installed or the
filter is worn.
Correctly install the water tank.
If the LED continues to flash,
install a new filter and rinse, see
chapter “Filter”.
Carbonated water in the
water tank�
Fill the water tank with fresh tap
water�
The coffee grounds are
not compact and are too
wet�
The grind setting is too
fine or too coarse, or not
enough ground coffee has
been used�
Adjust the grinding unit to a
coarser or finer setting, or use
2 level measuring spoons of
ground coffee�
LED
I
flashes.
Brewing unit (5) is soiled�
Clean the brewing unit (5)�
Too much preground
coffee in the
brewing unit (5)�
Clean the brewing unit (5) Put in
no more than 2 level measuring
spoons of ground coffee�
The brewing unit
mechanism is stiff�
Remove and clean the brewing
unit, see “Maintenance and daily
cleaning”.
Brewing unit (5) is missing
or has not been detected�
Switch off the appliance with the
brewing unit (5) in place, wait
three seconds and switch on the
appliance again�
Coffee or milk froth quality
varies widely.
Buildup of limescale in the
appliance�
Descale the appliance as
described in the instructions�
Water dripped onto the
inner floor of the appli
ance when the drip tray
(8) was removed�
Drip tray (8) removed too
soon�
Wait a few seconds after the
last drink was dispensed before
removing the drip tray (8).
The default settings have
been changed and need
to be reset�
Some settings have been
made that are no longer
required�
Press the power on/off button
O / I
(9) to switch off the appliance�
Press and hold the service button
(12) and the steam button (11)
and press the power on/off button
O / I
(9) to switch on the appliance�
Then press the start button (10) to
confirm. The default settings are
reset�
LEDs
flash.
The appliance has a fault� Please contact the hotline�
LEDs
flash.
Incorrect voltage.
Operate the appliance at
220 V240 V only.
LEDs
flash.
The ambient temperature is
too cold�
Operate the appliance at
temperatures > 5° C.
If you are unable to solve the problem, please call the hotline.
You will find the telephone numbers at the back of these instructions.