IOM-007
Installation Operation Manual for TC3A-107 and Similar EDUs
Page 16 of 19
•
Guide pins must never be removed from test connectors as this can lead to damage and will
invalidate the connector warranty.
Figure 12 . Tronic test connector examples
•
To perform any testing refer to specific project documentation for details of procedures.
NOTE: No part of the connectors should be dismantled prior to or during deployment,
apart from the removal of protective caps, since there are no user serviceable parts inside.
13. DI CONNECTOR SPECIFICATION
Electrical and Mechanical
Maximum current (dry topside)
4-way = 18A
7-way = 14A
12-way = 11A
Maximum current (submerged)
4-way = 35A
7-way = 22A
12-way = 20A
Maximum working voltage: 1000V rms phase to earth, 2000V rms phase to phase
Rated number of operations: 1000 mate / de-mate cycles (Power off)
Working pressure: 5800 psi (13,123 ft / 4000 metres water depth)
Working temperature range: -5 to +60
°
C
Onshore testing temperature range: -20°C to +50°C
Storage temperature range: -40 to +70
°
C