SXL-EX Operation, Installation, and Maintenance Manual
TABLE 1
PROGRAM MODE LEVELS
Level Sublevel
Description
1
1
2
3
4
5
6
7
8
Enable/Bypass Initiating Device Circuit Zone 1
Enable/Bypass Initiating Device Circuit Zone 2
Enable/Bypass Initiating Device Circuit Zone 3
Enable/Bypass Initiating Device Circuit Zone 4
Enable/Bypass Initiating Device Circuit Zone 5
Enable/Bypass Initiating Device Circuit Zone 6
Enable/Bypass Initiating Device Circuit Zone 7
Enable/Bypass Initiating Device Circuit Zone 8
2
1
2
3
4
5
6
7
8
Enable/Bypass Optional SZE-4X, SZE-8AX or SRC-8 Output Relay 1
Enable/Bypass Optional SZE-4X, SZE-8AX or SRC-8 Output Relay 2
Enable/Bypass Optional SZE-4X, SZE-8AX or SRC-8 Output Relay 3
Enable/Bypass Optional SZE-4X, SZE-8AX or SRC-8 Output Relay 4
Enable/Bypass Optional SZE-4X Open Collector Output 1 (or Relay 5 - SZE-8AX or SRC-8 only)
Enable/Bypass Optional SZE-4X Open Collector Output 2 (or Relay 6 - SZE-8AX or SRC-8 only)
Enable/Bypass Optional SZE-4X Open Collector Output 3 (or Relay 7 - SZE-8AX or SRC-8 only)
Enable/Bypass Optional SZE-4X Open Collector Output 4 (or Relay 8 - SZE-8AX or SRC-8 only)
3
1
2
3
4
5
6
7
8
Initiating Device Circuit Type Zone 1
Initiating Device Circuit Type Zone 2
Initiating Device Circuit Type Zone 3
Initiating Device Circuit Type Zone 4
Initiating Device Circuit Type Zone 5
Initiating Device Circuit Type Zone 6
Initiating Device Circuit Type Zone 7
Initiating Device Circuit Type Zone 8
4
1
2
Programs Signaling Type for Notification Appliance Circuit 1
Programs Signaling Type for Notification Appliance Circuit 2
5
1
2
3
4
5
6
7
8
Programs Open Collector/Relays to Follow Initiating Zone Circuit 1
Programs Open Collector/Relays to Follow Initiating Zone Circuit 2
Programs Open Collector/Relays to Follow Initiating Zone Circuit 3
Programs Open Collector/Relays to Follow Initiating Zone Circuit 4
Programs Open Collector/Relays to Follow Initiating Zone Circuit 5
Programs Open Collector/Relays to Follow Initiating Zone Circuit 6
Programs Open Collector/Relays to Follow Initiating Zone Circuit 7
Programs Open Collector/Relays to Follow Initiating Zone Circuit 8
6
1
2
3
4
Programs the Alarm Verification Timer
Programs the Notification Appliance Circuit Inhibit Timer
Programs the Notification Appliance Circuit Cutoff Timer
Programs the Zone Code Round Count (3 to 8 count range)
7
1
2
3
4
Programs Password Digit 1
Programs Password Digit 2
Programs Password Digit 3
Programs Password Digit 4
8
1
Select AC Fail Signal Delay
9
1
Enable/Disable SRC-8; Enable/Disable LED-3/4; Enable/Disable SLT-1; Enable/Disable SZE-4X/SZE-8AX