![Siemens SIWAREX WL230 BB-S SA Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/siemens/siwarex-wl230-bb-s-sa/siwarex-wl230-bb-s-sa_operating-instructions-manual_374535060.webp)
Variable
Value
Operating temperature range B
tu
-35 to +65 °C
Storage temperature range B
ts
-40 to +80 °C
Sensor material
Steel, nickel-plated
Degree of protection according to EN 60 529
IP67
Maximum tightening torque for the fixing bolts
for E
max
= 100; 250; 500 kg, 1 t, 2 t
for E
max
= 3; 5 t
for E
max
= 10 t
75 Nm
500 Nm
750 Nm
Cable connection
for E
max
= 100; 250; 500 kg, 1 t, 2 t
for E
max
= 3; 5; 10 t
Four-core, shielded PU cable
4 m
6 m
1)
Output is current-calibrated
9.1.11
SIWAREX WL230 SB-S SA
Table 9-11
Technical data SIWAREX WL230 SB-S SA
Variable
Value
Type series
WL230
Designation
SB-S SA
Construction type
Shear beam
Possible applications
Platform scales,
overhead rail scales,
container weighers,
conveyor scales
Rated load E
max
500 kg
1; 2; 5 t
Accuracy class according to OIML R60
C3
1)
Max. scale interval n
LC
3000
Min. scale interval V
min
for E
max
= 500 kg
for E
max
= 1; 2; 5 t
1)
E
max
/ 10000
E
max
/ 15000
Combined error F
comb
± 0.02% C
n
Deviation F
V
± 0.02% C
n
Creep error F
cr
30 min
± 0.02% C
n
Temperature coefficient
Characteristic value T
Kc
Zero signal T
Ko
0.017% C
n
/ 10 K
0.023% C
n
/ 10 K
Min. initial loading E
min
0 kg
Maximum working load L
u
150% E
max
Break load L
d
300% E
max
Maximum lateral load L
lq
100% E
max
Technical data
9.1 Functional data
SIWAREX WL200
60
Operating Instructions, 12/2021, A5E02199611B-13
Содержание SIWAREX WL230 BB-S SA
Страница 6: ...Table of contents SIWAREX WL200 6 Operating Instructions 12 2021 A5E02199611B 13 ...
Страница 10: ...Introduction 1 6 Notes on warranty SIWAREX WL200 10 Operating Instructions 12 2021 A5E02199611B 13 ...
Страница 24: ...Installing 4 3 Dismantling SIWAREX WL200 24 Operating Instructions 12 2021 A5E02199611B 13 ...