SITRANS P220 (7MF1567)
16
A5E03304437-AA, 09/2017
Measuring accuracy
•
Lower range value and measuring span
0.25% of full scale value/year
Effect of ambient temperature
•
Lower range value and measuring span
0.25%/10 K of full scale value
•
Influence of vibration (per IEC 60068-2-6)
0.005%/g to 500 Hz in all directions
•
Effect of auxiliary power supply
0.005%/V
Rated conditions
Process temperature
-30 … +120 °C (-22 … +248 °F)
Ambient temperature
-25 … +85 °C (-13 … +185 °F)
•
Altitude
Max. 2000 m mean sea level
Use a suitable power supply at an altitude of more than 2
000 m (6,562 ft.) above sea level.
•
Relative humidity
0 ... 100%
Storage temperature
-50 ... +100 °C (-58 ... +212 °F)
Degree of protection (to EN 60529)
•
IP65 with connector to EN 175301-803-A
•
IP67 with M12 connector
•
IP67 with cable
•
IP67 with fast-fit cable gland
Electromagnetic compatibility
•
To EN 61326-1
•
To EN 61326-2-3
•
To NAMUR NE21, only for ATEX devices and with a
max. measurement error of
≤
1%
Construction
Weight
Approx. 0.090 kg (0.198 lb)
Process connections
Dimensional drawings
Electrical connections
•
Connector to EN 175301-803-A Form A with cable inlet M16x1.5 or ½-14NPT
or Pg 11
•
M12 connector
•
2 or 3-wire (0.5 mm
2
) cable (
∅
± 5.4 mm)
•
Fast-fit cable gland
Material of the wetted parts
•
Measuring cell
Stainless steel, Mat. No. 1.4016
•
Process connection
Stainless steel, Mat. No. 1.4404 (SST 316 L)
Material of the non-wetted parts
•
Enclosure
Stainless steel, Mat. No. 1.4404 (SST 316 L)
•
Rack
•
Plastic
•
CuZn, nickel-plated (M12 connector)
•
Cable
PVC spec.
Certificates and approvals
Classification according to Pressure Equipment Directive
(PED 97/23/EC)
For gases of Fluid Group 1 and liquids of Fluid Group 1;
meets requirements of Article 3 Para. 3 (good engineering
practice)