Error
Reason
Removal
Signal lamp flashes red
Error on the vibrating element
Check if the vibrating element is
damaged or extremely corroded.
Interference on the electronics mod-
ule
Exchanging the electronics module
instrument defective
Exchange the instrument or send it
in for repair
Depending on the reason for the fault and the measures taken, the
steps described in chapter "
Set up
" may have to be carried out again.
7.3 Exchanging the electronics
If the electronics module is defective, it can be replaced by the user.
In Ex applications only an electronics module with respective Ex ap-
proval may be used.
You can find all the information you need to carry out an electronics
exchange in the handbook of the new electronics module.
In general, all electronics modules of series SW60 can be inter-
changed. If you want to use an electronics module with a different
signal output, you carry out the complete setup. You find the neces-
sary, suitable operating instruction on our homepage.
Note:
Keep in mind that enamelled instrument versions need special
electronics modules. These electronics modules are called SW60E or
SW60E1.
7.4 How to proceed if a repair is necessary
If it is necessary to repair the instrument, please contact Siemens
Milltronics Process Instruments Inc. You find the locations on our
homepage "www.siemens.com/processautomation".
Reaction after fault recti-