SITRANS F M MAGFLO
®
®
®
®
®
4
SFIDK.PS.026.E5.02
ENGLISH
2.
Installation
2.
Installation
Category 2 equipment
In addition to the sensor, the MAG 6000 I as
remote or compact mounted may be installed in
Ex zone 1 and zone 2.
2.2 Installation of sensor
Installation of transmitter can be remote or
compact mounted.
2.1 Installation of
transmitter
Hazardous area
The sensor must always be completely full with
liquid.
Therefore avoid:
•
Installation at the highest point in the pipe
system
•
Installation in vertical pipes with free outlet
For partially filled pipes or pipes with down-
ward flow and free outlet the flowmeter should
be located in a U-tube.
Installation in vertical pipes
Recommended flow direction: upwards. This
minimizes the effect on the measurement of
any gas/air bubbles in the liquid.