background image

Technical data 

 

6.8 Dimension drawing 

 

SITOP PSU100L 

42

 

Manual, 08.2016, C98130-A7603-A1-2-7629 

Содержание SITOP PSU100L 6EP1332-1LB00

Страница 1: ...1334 1LB00 SITOP PSU100L 24V 20A 6EP1336 1LB00 08 2016 C98130 A7603 A1 2 7629 Overview Safety instructions 1 Description device design dimension drawing 2 Mounting removal 3 Mounting position mounting clearances 4 Installation 5 Technical data 6 Safety approvals EMC 7 Ambient conditions 8 Applications 9 Environment 10 Service Support 11 ...

Страница 2: ...operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING S...

Страница 3: ... does not compromise when it comes to quality and reliability The key benefits of the product include 1 phase input voltage range with manual switchover Narrow design Good efficiency Green LED for 24 V O K Can be connected in parallel No lateral installation clearances required Ambient temperature from 0 C to 60 C exception 6EP1336 1LB00 0 C to 70 C from 45 C with derating Cooling through natural ...

Страница 4: ...ice options are available Regulated power supply unit SITOP PSU100L Type Order number Input 120 230 V AC Output 24 V DC 2 5 A 6EP1332 1LB00 Input 120 230 V AC Output 24 VDC 5 A 6EP1333 1LB00 Input 120 230 V AC Output 24 V DC 10 A 6EP1334 1LB00 Input 120 230 V AC Output 24 V DC 20 A 6EP1336 1LB00 ...

Страница 5: ...diagram 15 2 7 Dimensions and weight 16 3 Mounting removal 19 4 Mounting position mounting clearances 21 4 1 Standard mounting position 21 4 2 Other mounting positions 23 4 2 1 6EP1332 1LB00 23 4 2 2 6EP1333 1LB00 25 4 2 3 6EP1334 1LB00 27 4 2 4 6EP1336 1LB00 29 5 Installation 31 5 1 Line side connection 31 5 2 Output side connection 32 6 Technical data 33 6 1 Input 33 6 2 Output 34 6 3 Efficiency...

Страница 6: ... Test voltage 44 7 3 Approvals 45 7 4 EMC 45 8 Ambient conditions 47 9 Applications 49 9 1 Parallel connection to increase power rating 49 9 2 Parallel connection for redundancy 51 9 3 Series connection for increased voltage 52 9 4 Protection against short time voltage dips 53 10 Environment 55 11 Service Support 57 ...

Страница 7: ...al injury as well as extensive property damage Only appropriately qualified personnel may work on or in the vicinity of this equipment Perfect safe and reliable operation of this equipment is dependent on proper transportation storage installation and mounting Before installation or maintenance work can begin the system s main switch must be switched off and measures taken to prevent it being swit...

Страница 8: ...Safety instructions SITOP PSU100L 8 Manual 08 2016 C98130 A7603 A1 2 7629 ...

Страница 9: ...ctronically regulated DC voltage that can be set via a potentiometer is available at the output of the device The output of the device is isolated no load proof and short circuit proof The LED display is used to signal the operating state AC input DC output Potentiometer Uout Indicator light 24 V O K Voltage selector switch DIN rail slider Natural convection Clearance above below Figure 2 1 Design...

Страница 10: ...ures of at least 65 C 75 C The line input terminals can be used to establish the connection to supply voltage The output terminals are used to connect to the loads to be supplied see also Section Installation Page 31 Connections and terminal designations Line input L1 N PE One screw terminal each Output 2 screw terminals Output 2 screw terminals 1 Do not subject the end stop to higher loads Figure...

Страница 11: ...evice design dimension drawing 2 2 Connections and terminal designation SITOP PSU100L Manual 08 2016 C98130 A7603 A1 2 7629 11 1 Do not subject the end stop to higher loads Figure 2 3 Terminal data for 6EP1336 1LB00 ...

Страница 12: ... long supply lines to the connected load Figure 2 4 Potentiometer example 6EP1334 1LB00 NOTICE Thermal overload possible When adjusting the output voltage to greater than the rated voltage the output current must be derated by 4 V or the permissible ambient temperature must be taken into account with 3 C V Note It is only permissible to use an insulated screwdriver when actuating the potentiometer...

Страница 13: ...24 V 2 5 A 6EP1333 1LB00 24 V 5 A 6EP1334 1LB00 24 V 10 A 6EP1336 1LB00 24 V 20 A Operating display LED green for 24 V O K Figure 2 5 Operating display and signaling example 6EP1334 1LB00 Signaling 6EP1332 1LB00 24 V 2 5 A 6EP1333 1LB00 24 V 5 A 6EP1334 1LB00 24 V 10 A 6EP1336 1LB00 24 V 20 A LED lights up green Normal operation output voltage 20 V 0 5 V LED off No supply voltage ...

Страница 14: ...ector switch Selector switch for the input voltage range Figure 2 6 120 V 230 V voltage selector switch example 6EP1334 1LB00 The selector switch as delivered factory setting is in the 230 V position It must be moved to the appropriate position for operation in the 120 V range The selector switch can only be actuated in the de energized state ...

Страница 15: ...Description device design dimension drawing 2 6 Block diagram SITOP PSU100L Manual 08 2016 C98130 A7603 A1 2 7629 15 2 6 Block diagram Setting range for 6EP1336 1LB00 22 6 28 V Figure 2 7 Block diagram ...

Страница 16: ...e design dimension drawing 2 7 Dimensions and weight SITOP PSU100L 16 Manual 08 2016 C98130 A7603 A1 2 7629 2 7 Dimensions and weight Figure 2 8 Dimension drawing 6EP1332 1LB00 Figure 2 9 Dimension drawing 6EP1333 1LB00 ...

Страница 17: ... 17 Figure 2 10 Dimension drawing 6EP1334 1LB00 Figure 2 11 Dimension drawing 6EP1336 1LB00 6EP1332 1LB00 24 V 2 5 A 6EP1333 1LB00 24 V 5 A 6EP1334 1LB00 24 V 10 A 6EP1336 1LB00 24 V 20 A Dimensions W H D in mm 32 5 125 120 3 50 125 120 3 70 125 120 3 110 125 125 Weight approx 0 32 kg Approx 0 5 kg Approx 0 75 kg 1 65 kg ...

Страница 18: ...Description device design dimension drawing 2 7 Dimensions and weight SITOP PSU100L 18 Manual 08 2016 C98130 A7603 A1 2 7629 ...

Страница 19: ...H35 15 7 5 EN 60715 Mounting To mount the device position it with the mounting rail guide at the upper edge of the standard mounting rail and press down to lock it into place If this is too difficult press slider at the same time as described under Removal Removal To remove pull up the slider using a screwdriver see Figure 3 1 Removal example 6EP1334 1LB00 Page 19 and disengage the device at the b...

Страница 20: ...Mounting removal SITOP PSU100L 20 Manual 08 2016 C98130 A7603 A1 2 7629 ...

Страница 21: ...evice must be mounted vertically in such a way that the input terminals and the output terminals are at the bottom to ensure correct cooling A clearance of at least 50 mm should be maintained above and below the device No space is required at the side Output current as a function of the ambient temperature and mounting height Figure 4 1 6EP1332 1LB00 mounting position Figure 4 2 6EP1333 1LB00 moun...

Страница 22: ...ting clearances 4 1 Standard mounting position SITOP PSU100L 22 Manual 08 2016 C98130 A7603 A1 2 7629 Figure 4 3 6EP1334 1LB00 mounting position Figure 4 4 6EP1336 1LB00 mounting position Figure 4 5 Mounting height derating ...

Страница 23: ...bserved in accordance with the following diagrams Note In the case of mounting positions that deviate from the standard mounting position reduced mechanical resistance of the devices against vibration and shock must be expected Particularly when installing on a vertically fastened standard mounting rail additional measures may be required e g to prevent the device from slipping on the standard mou...

Страница 24: ...learances 4 2 Other mounting positions SITOP PSU100L 24 Manual 08 2016 C98130 A7603 A1 2 7629 Figure 4 8 6EP1332 1LB00 mounting position 3 Figure 4 9 6EP1332 1LB00 mounting position 4 Figure 4 10 6EP1332 1LB00 mounting position 5 ...

Страница 25: ... 2 Other mounting positions SITOP PSU100L Manual 08 2016 C98130 A7603 A1 2 7629 25 4 2 2 6EP1333 1LB00 Figure 4 11 6EP1333 1LB00 mounting position 1 Figure 4 12 6EP1333 1LB00 mounting position 2 Figure 4 13 6EP1333 1LB00 mounting position 3 ...

Страница 26: ...ng position mounting clearances 4 2 Other mounting positions SITOP PSU100L 26 Manual 08 2016 C98130 A7603 A1 2 7629 Figure 4 14 6EP1333 1LB00 mounting position 4 Figure 4 15 6EP1333 1LB00 mounting position 5 ...

Страница 27: ... 2 Other mounting positions SITOP PSU100L Manual 08 2016 C98130 A7603 A1 2 7629 27 4 2 3 6EP1334 1LB00 Figure 4 16 6EP1334 1LB00 mounting position 1 Figure 4 17 6EP1334 1LB00 mounting position 2 Figure 4 18 6EP1334 1LB00 mounting position 3 ...

Страница 28: ...ng position mounting clearances 4 2 Other mounting positions SITOP PSU100L 28 Manual 08 2016 C98130 A7603 A1 2 7629 Figure 4 19 6EP1334 1LB00 mounting position 4 Figure 4 20 6EP1334 1LB00 mounting position 5 ...

Страница 29: ... 2 Other mounting positions SITOP PSU100L Manual 08 2016 C98130 A7603 A1 2 7629 29 4 2 4 6EP1336 1LB00 Figure 4 21 6EP1336 1LB00 mounting position 1 Figure 4 22 6EP1336 1LB00 mounting position 2 Figure 4 23 6EP1336 1LB00 mounting position 3 ...

Страница 30: ...ng position mounting clearances 4 2 Other mounting positions SITOP PSU100L 30 Manual 08 2016 C98130 A7603 A1 2 7629 Figure 4 24 6EP1336 1LB00 mounting position 4 Figure 4 25 6EP1336 1LB00 mounting position 5 ...

Страница 31: ...pply TN or TT system according to VDE 0100 T 300 IEC 364 3 with a rated voltage of 120 230 V AC 50 60 Hz Figure 5 1 Line connection example 6EP1334 1LB00 The line supply is connected using terminals L1 N and PE see Figure 5 1 Line connection example 6EP1334 1LB00 Page 31 and must be implemented according to IEC 60364 and EN 50178 A protective device miniature circuit breaker or circuit breaker and...

Страница 32: ...e output of the power supply is no load overload and short circuit proof If an overload occurs the electronic current limiting function limits the output current to a maximum value refer to Chapter Technical data Page 33 Figure 5 2 Connection of the output voltage example 6EP1334 1LB00 The output voltage is connected via the and terminals at the output of the power supply see Figure 5 2 Connection...

Страница 33: ...0 ms 20 ms 20 ms 20 ms Power failure buffering at 93 187 V at 85 170 V Rated line frequency 50 60 Hz Line frequency range 47 63 Hz Input current at rated value of input voltage 120 V 1 1 A 2 1 A 4 1 A 5 55 A Input current at rated value of input voltage 230 V 0 65 A 1 15 A 2 A 2 35 A Inrush current limiting 25 C max 27 A 32 A 65 A 45 A I t max 0 3 A2s 0 8 A2s 3 3 A2s Duration of the switch on curr...

Страница 34: ...5 Residual ripple Peak peak max 150 mV 150 mV 150 mV 150 mV for a band width of 20 MHz Residual ripple peak peak typ 10 mV 50 mV 50 mV 80 mV for a band width of 20 MHz Spikes peak peak max bandwidth 200 MHz 240 mV 240 mV 240 mV Spikes peak peak typ bandwidth approx 20 MHz 50 mV 150 mV 150 mV 200 mV Adjustment range 22 8 26 4 V 22 8 28 V Product function output voltage can be adjusted Yes Adjusting...

Страница 35: ... 45 C 1 75 A to 60 C 0 5 A 5 A to 45 C 3 5 A to 60 C 0 10 A 10 A to 45 C 7 A to 60 C 0 20 A 20 A to 45 C 12 5 A to 70 C Output active power typical 60 W 120 W 240 W 480 W Can be connected in paral lel to increase the power rating Yes Number of devices that can be connected in parallel to increase the power rating units 2 Output characteristic See Figure 6 3 Out put characteristic 6EP1332 1LB00 Pag...

Страница 36: ...data 6 2 Output SITOP PSU100L 36 Manual 08 2016 C98130 A7603 A1 2 7629 Figure 6 3 Output characteristic 6EP1332 1LB00 Figure 6 4 Output characteristic 6EP1333 1LB00 Figure 6 5 Output characteristic 6EP1334 1LB00 ...

Страница 37: ...ls below approx 10 V the device switches off and automatically restarts see Figure 6 3 Output characteristic 6EP1332 1LB00 Page 36 and Figure 6 4 Output characteristic 6EP1333 1LB00 Page 36 This behavior is repeated as long as the overload condition is present only for 6EP1332 1LB00 and 6EP1333 1LB00 The 6EP1334 1LB00 device has a U I characteristic see Figure 6 5 Output characteristic 6EP1334 1LB...

Страница 38: ...iciency 6EP1332 1LB00 24 V 2 5 A 6EP1333 1LB00 24 V 5 A 6EP1334 1LB00 24 V 10 A 6EP1336 1LB00 24 V 20 A Efficiency at Uout rated Iout rated approx 85 86 89 93 Power loss at Uout rated Iout rated approx 9 W 17 W 34 W 33 6 W Figure 6 7 Efficiency 6EP1332 1LB00 Figure 6 8 Efficiency 6EP1333 1LB00 ...

Страница 39: ...Technical data 6 3 Efficiency SITOP PSU100L Manual 08 2016 C98130 A7603 A1 2 7629 39 Figure 6 9 Efficiency 6EP1334 1LB00 Figure 6 10 Efficiency 6EP1336 1LB00 ...

Страница 40: ... 1LB00 24 V 5 A 6EP1334 1LB00 24 V 10 A 6EP1336 1LB00 24 V 20 A Output overvoltage protection 33 V 33 V 33 V 33 V Current limitation typ 2 6 A 5 25 A 23 4 A Properties of the out put short circuit proof Yes Short circuit protection Electronic trip automat ic restart Electronic trip automat ic restart U I characteristic U I characteristic Continuous short circuit current rms val ue typical 12 6 A 2...

Страница 41: ... mm 225 mm 225 mm 225 mm Weight approx 0 32 kg 0 5 kg 0 75 kg 1 65 kg Product properties of the housing housing that can be lined up next to other housings Yes Type of mount ing panel mounting No Type of mounting rail mounting Yes Type of mounting S7 300 rail mounting No Mounting Can be snapped onto standard TH35 15 7 5 EN 60715 mounting rails 6 8 Dimension drawing See chapter Dimensions and weigh...

Страница 42: ...Technical data 6 8 Dimension drawing SITOP PSU100L 42 Manual 08 2016 C98130 A7603 A1 2 7629 ...

Страница 43: ...P1334 1LB00 24 V 10 A 6EP1336 1LB00 24 V 20 A Primary secondary galvanic isolation Yes Galvanic isolation SELV output voltage Uout acc to EN 60950 1 and EN 50178 Protection class Class I Degree of protection EN 60529 IP20 Leakage current typ 0 4 mA 0 4 mA 0 8 mA 0 52 mA Leakage current max 3 5 mA Test voltage see Table Test voltage Page 44 ...

Страница 44: ...A B Connect the input terminals with one another L N Connect the output terminals and PE together Test C Measure the output terminals with respect to PE Table 7 1 Test voltage Test time Prim sec A Prim PE B Sec PE C Type test 60 s 4200 VDC 2200 VDC 700 VDC 60 s 3000 VAC 1500 VAC 500 VAC Production test 1 s 2200 VDC 2200 VDC 500 VDC 1 s 1500 VAC 1500 VAC 350 VAC Field test 1 s 2200 VDC 2200 VDC 500...

Страница 45: ...elds EN 61000 4 3 80 6000 MHz 10 V m 895 905 MHz and 1 89 GHz 10 V m High speed transient dis turbance variables burst EN 61000 4 4 2 kV at line connection 1 kV at DC output Surge voltages EN 61000 4 5 1 kV symmetrical on line connections 2 kV asymmetrical on line connections 500 V symmetrical asymmetrical on DC output cables High frequency fields EN 61000 4 6 10 V 0 15 80 MHz Magnetic fields EN 6...

Страница 46: ...Safety approvals EMC 7 4 EMC SITOP PSU100L 46 Manual 08 2016 C98130 A7603 A1 2 7629 ...

Страница 47: ...0068 2 78 humid heat constant EN 60068 2 14 temperature change Transport and storage temperature 40 85 C Tests packed for shipping according to EN 60068 2 1 cold EN 60068 2 2 dry heat EN 60068 2 30 humid heat cyclic Humidity class Climatic class 3K3 according to EN 60721 without condensation Degree of pollution 2 Mechanical stressing in operation Tested according to EN 60068 2 6 Vibration test Fc ...

Страница 48: ...hydrogen sulfide Atmospheric pressure Operation 1080 795 hPa 1000 2000 m For operation at altitudes of 2000 m up to 6000 m above sea level output must be derated by 7 5 1000 m or the ambient temperature must be reduced by 5 K 1000 m see Figure 4 5 Mounting height derating Page 22 Overvoltage category III to 2000 m EN 50178 II from 2000 m to 6000 m EN 50178 II to 2000 m EN 60950 1 I from 2000 m to ...

Страница 49: ...ible The power supplies connected in parallel must be switched on simultaneously with a common switch in the line feeder cable e g with the main switch available in control cabinets The output voltages measured in no load operation for the power supplies that are not yet connected in parallel should not deviate more than a maximum of 50 mV This usually corresponds to the factory setting If the out...

Страница 50: ... two power supplies For connection of more than two power supplies in parallel additional measures must be taken to prevent high backward feeding currents in the event of a secondary device fault For this purpose a suitable protective circuit e g decoupling diode or DC conform circuit breaker must be installed between each terminal of the power supply and the common connection point ...

Страница 51: ...fails then the other automatically takes over the power supply If one of the power supplies fails then this is signaled using an LED on the redundancy module as well as an isolated relay contact When dimensioning the system it must be ensured that n 1 redundant connected power supplies can handle the total power requirement of the remaining n power supplies Note For a high reliability of the suppl...

Страница 52: ...ly The terminal of the first power supply and the terminal of the second power supply are routed to the load Depending on the grounding point of the secondary output voltages voltages of 48 V 24 V or 48 V can be realized In the case of an asymmetric load distribution it is not possible to guarantee correct functionality WARNING SELV is not guaranteed in the case of a fault When connecting two powe...

Страница 53: ...ease the line buffering time in the device using an additional SITOP PSE201U buffer module The SITOP PSE201U buffer module based on electrolytic capacitors is connected in parallel to the 24 V power supply output SITOP PSE201U manual http support automation siemens com WW view en 41129219 The buffer time is 200 ms at 40 A up to 1 6 s for a load current of 5 A This time can be increased a multiple ...

Страница 54: ...Applications 9 4 Protection against short time voltage dips SITOP PSU100L 54 Manual 08 2016 C98130 A7603 A1 2 7629 ...

Страница 55: ...nvironment 10 The devices are in conformance with RoHS As a rule only non silicon precipitating materials are used Disposal guidelines Packaging and packaging aids can and should always be recycled The product itself may not be disposed of as domestic refuse ...

Страница 56: ...Environment SITOP PSU100L 56 Manual 08 2016 C98130 A7603 A1 2 7629 ...

Страница 57: ...es is available in the Internet at the SITOP homepage SITOP http www siemens de sitop Information material SITOP information can be downloaded from the Internet Information and download center http www siemens de sitop infomaterial CAx data 2D 3D data and circuit diagram macros can be downloaded from the Internet Siemens image database http www siemens de sitop cax Request all CAx data via the CAx...

Страница 58: ...629 Contact persons If you have any questions regarding the use of our products then contact the Siemens contact person in your regional Siemens sales office You can find these addresses as follows On the Internet http www siemens de automation partner In Catalog CA 01 ...

Отзывы: