background image

Operation 

21 

Siemens AG

 

 EN 

  

05.2010 

 

 

7.2 

Front panel buttons and LEDs 

 

Power LED 

The Power LED is lit when the unit is On. 

HDD LED 

The HDD LED flickers when the DVR is recording or searching video on the hard disk 
drive. 

Alarm LED 

The Alarm Out LED is lit when alarm output or internal buzzer is activated. 

Network LED 

The NETWORK LED is lit when the unit is connected to a network via Ethernet. 

Clip Copy LED 

The Clip Copy LED is lit when the DVR is clip-copying. 

Camera buttons 
(1 to 16) 

Pressing the individual camera buttons will cause the selected camera to display full 
screen. Buttons 1 to 9 are also used to enter passwords. 

In the PTZ mode, pressing the button 1 zooms in the screen and the button 2 zooms out 
the screen, pressing the button 3 focuses near and button 4 focuses far, and pressing the 
button 5 moves to the preset and button 6 saves the preset. 

Zoom/PTZ button 

Pressing the Zoom/PTZ button enters zoom mode and a rectangle appears on the screen. 

You can use the arrow buttons to move the rectangle to another area. Pressing the 

 

(Enter/Pause) button zooms in the image in rectangle. 

Pressing the button for two seconds or longer allows you to enter PTZ mode. 

Display/Spot button 

Pressing the Display/Spot button toggles different display formats. The available formats 
are: PIP, 2x2, 3x3 and 4x4. 

Pressing and holding the button for two seconds or longer allows you to select which 
cameras will display on the Spot monitor. 

Group/Sequence button 

When in the live mode, pressing the Group/Sequence button changes the screen from the 
current camera group to the next camera group, and the screen displays the page 
number. Pressing and holding the button for two seconds or longer displays live channels 
sequentially. 

Menu/Cameo button 

 

Pressing the Menu/Cameo button enters the Setup screen. You will need to enter the 
authorized user and password to access Setup. Pressing the button also closes the 
current menu or setup dialog box. In the Playback mode, pressing the button displays the 
Search menu. 

Pressing and holding the button for two seconds or longer enters the cameo mode. The 
yellow outline surrounding the video indicates the active cameo, and pressing the arrow 
buttons moves the active cameo. Pressing the desired camera button in the active cameo 

edits the cameo and displays the video of selected camera. Pressing the 

 (Enter/Pause) 

button exits the Active Cameo mode. Selecting 

Exit Group Edit 

in the cameo menu 

displayed when pressing the Menu/Cameo button also exits the Active Cameo mode. 

Panic button 

Pressing the Panic button starts panic recoding of all camera channels, and displays 

 

on the screen. Pressing the button again will stop panic recording. 

Clip Copy button 

Pressing the Clip Copy button allows you to copy video clips. 

Alarm button 

The Alarm button has two functions. First, it will reset the DVR’s outputs including the 
internal buzzer during an alarm. Second, it will display the event log when you are in the 
live monitoring mode unless there is an active alarm. This operation can be user password 
protected. 

Playback button 

 

Pressing the Playback button enters the playback mode, and pressing the button again 
exits the playback mode. When entering the playback mode, video is paused. Pressing 
the Right arrow button plays back video at regular speed. The screen displays   when the 
DVR is in the Pause mode and the screen displays   when the DVR is playing back 
video. 

Enter/Pause button 

 

In the live monitoring mode, pressing the 

 button freezes the current screen and the 

screen displays 

 icon. When in the playback mode, pressing the 

 button pauses 

playing video. When in the setup mode, pressing the 

 button selects a highlighted item 

or completes an entry that you have made  

Up, Down, Left, Right Arrow 
buttons 

These buttons are used to navigate through menus and GUI.  

The Up and Down arrow buttons are also used to change numbers by highlighting a 
number in the menu and by increasing or decreasing the number’s value. 
The Left and Right arrow buttons are also used to play back images in the playback mode. 
Pressing the Right arrow button plays video at regular speed, and pressing the button 
again toggles the playback speed from x2, x3 and x4. Pressing the Left arrow button plays 
video backward at high speed, and pressing the button again toggles the playback speed 
from x2, x3 and x4. 

 

Содержание SISTORE AX16 1000/400 V4.0

Страница 1: ...6LHPHQV Digital Video Recorder SISTORE AX8 1000 200 V4 0 SISTORE AX16 1000 400 V4 0 Installation Manual ...

Страница 2: ...peration Manual NOTE This document cannot deal with every possible application Further useful product information as well as application examples and supplementary information to the manuals can be found on our intranet website https psp sbt siemens com Product Support Platform Trademarks SISTORE is a trademark of Siemens Microsoft is a registered trademark and Windows a trademark of Microsoft Cor...

Страница 3: ...monitor 11 6 4 Connecting a VGA monitor 11 6 5 Connecting Audio In Out 12 6 6 Connecting alarms 12 6 7 Connecting to the RS485 port 13 6 8 Connecting to the USB ports 14 6 9 Connecting to the RS232 port 14 6 10 Connecting to the network port 14 6 11 Factory reset 15 6 12 Connecting the power cord 15 6 13 Connector pin outs 16 6 14 Connection diagrams 17 6 14 1 Connecting the remote keyboard CKA482...

Страница 4: ......

Страница 5: ...n installation operation or disposal of a product must be adhered to in addition to the instructions in the product documentation Radio interference with other devices in the environment z This is a Class A device This equipment may cause radio interference in a residential installation In this case the user is encouraged to perform appropriate measures to correct the interference z The device may...

Страница 6: ... objects on the device Danger of electrical shock due to incorrect connection z Use the device only in conjunction with a power supply cable that has been approved in your country and complies with the national standards z This product is designed for TN power systems and for IT power systems in Norway with 230 V phase to phase voltage Do not connect the device to any other IT power systems Damage...

Страница 7: ...quirements of the following European directives The EU declaration of conformity is available to the responsible agencies at Siemens AG Siemensallee 84 76181 Karlsruhe Germany European Directive 2004 108 EC Electromagnetic Compatibility Compliance with the European Directive 2004 108 EC has been proven by testing according to the following standards Emitted interference EN 61000 6 4 EN 55022 Class...

Страница 8: ...remote keyboard User administration 64 groups 256 users groups access right programmable per group Recording Playback Compression H 264 technology video ADPCM audio Recording speed SISTORE AX8 up to 200 ips PAL up to 240 ips NTSC SISTORE AX16 up to 400 ips PAL up to 480 ips NTSC Recording resolution CIF 2CIF 4CIF Recording mode Time Lapse Event Pre Event up to 30 min Text In Panic Search mode Date...

Страница 9: ...hen installing an internal DVD RW drive connect the SATA I O cable to the SATA3 socket 4 Details for ordering Type Order No Designation Weight SISTORE AX8 1000 200 S54569 C72 B3 SISTORE AX8 1000 GB 200 ips 10 2 kg SISTORE AX16 1000 400 S54569 C92 B3 SISTORE AX16 1000 GB 400 ips 10 2 kg 5 Scope of delivery z Digital video recorder z Power cord z CD ROM including Configuration Operation Manual Multi...

Страница 10: ...power supply before installing the device The diagram below shows a typical DVR installation Fig 1 Typical DVR installation Fig 2 16 channel DVR rear panel 1 Video Input 6 RS232C Port 2 Video Loop Through 7 Audio In Out 3 RS485 Port 8 Video Out 4 Alarm Input Output 9 Factory Reset Switch 5 Network Port 10 Power Cord Connector ...

Страница 11: ...cting the loop through video Fig 4 Video loop through connectors If you would like to connect your video source to another device you can use the Loop BNC connectors NOTE The Loop BNC connectors are auto terminated Do not connect a cable to the Loop BNC unless it is connected to a terminated device because it will cause poor quality video 6 3 Connecting the monitor Fig 5 Video Out connectors Conne...

Страница 12: ...mplifier The DVR does not have a pre amplifier for audio input so the audio input should be from an amplified source not directly from a microphone 6 6 Connecting alarms Fig 8 Alarm Input connectors NOTE To make connections on the Alarm Connector Strip press and hold the button and insert the wire in the hole below the button After releasing the button tug gently on the wire to make certain it is ...

Страница 13: ...s internal buzzer Mechanical or electrical switches can be wired to the ARI Alarm Reset In and GND Ground connectors The threshold voltage is below 0 3V and should be stable at least 0 5 seconds to be detected Connect the wires to the ARI Alarm Reset In and GND Ground connectors 6 7 Connecting to the RS485 port Fig 11 RS485 connector The DVR can be controlled remotely by an external device or cont...

Страница 14: ...a computer A USB to Serial converter can be connected to the USB port Multiple text in devices can be used with a USB to Serial converter 6 9 Connecting to the RS232 port Fig 13 RS232 connector An RS232 port is provided to connect a remote control keyboard 6 10 Connecting to the network port Fig 14 Network connector The DVR can be networked using the 10 100Mb Ethernet connector Connect a Cat5 cabl...

Страница 15: ...EDs on the front panel are lit NOTE When the DVR successfully resets to factory defaults all the LEDs on the front panel flash five times 5 Release the reset switch Î All of the DVR s settings are now at the original settings it had when it left the factory 6 12 Connecting the power cord Fig 16 Power cord connector Connect the AC power cord to the DVR and then to a wall outlet CAUTION Route power ...

Страница 16: ...arm Outputs Normally Open C Relay Common ARI Alarm Reset In RS485 connector pin outs Master unit Slave unit RX TX J To J TX RX RX TX J To J TX RX RS232 connector pin outs Pin 1 DCD Data Carrier Detect Pin 2 RXD Receive Data Pin 3 TXD Transmit Data Pin 4 DTR Data Terminal Ready Pin 5 GND System Ground Pin 6 DSR Data Set Ready Pin 7 RTS Request To Send Pin 8 CTS Clear To Send Pin 9 RI Ring Indicator...

Страница 17: ... n In the menu RS232 RS485 RS232 RS485 Baud Rate 19 200 19 200 CCDA1415 1200 9600 CCDA1425 1435 Parity None None Data Bit 8 8 Stop Bit 1 1 Usage Remote control PTZ control Pin out RS232 connection SISTORE AX RS 232 CKA4820 RS232 Com 1A Pin 1 Pin 1 Pin 2 Pin 3 Pin 3 Pin 2 Pin 5 Pin 5 Pin 9 Pin 9 Pin out RS485 connection SISTORE AX RS 485 CCDA14xx Tx Data Tx Data RS485 SISTORE AX ID 1 RS232 CKA4820 ...

Страница 18: ... View Stored fixed camera position that you can return to by entering the preset number Auto panning The dome camera will perform an auto scan operation Tour Repeat pre configured sequence of presets that the dome will move between continuously Device menu Open the menu of the dome for configuration OSD navigation Once the OSD is displayed on the video output navigation and parameter setup can be ...

Страница 19: ...Alarm In Alarm Device Mechanical alarm input device can be used as above and 5 V TTL logic can also be used NOTE The threshold voltage of alarm input is below 5 V Recommended RELAY Alarm Out connection Mechanical alarm output device can be used as above NC NO is a relay output which sinks 2A 125VAC and 1A 30VDC ...

Страница 20: ...ayback Mode Button 5 Clip Copy LED 14 Menu Cameo Button 6 Camera Buttons 15 Enter Pause Button 7 Zoom PTZ Button 16 Arrow Buttons 8 Panic Button 17 USB Connector 9 Display SPOT Button Display Modes Press the desired camera number button to view the desired camera image and press the Display button repeatedly to toggle between different display formats 4x4 3x3 2x2 and PIP Recording Once you have in...

Страница 21: ...or longer enters the cameo mode The yellow outline surrounding the video indicates the active cameo and pressing the arrow buttons moves the active cameo Pressing the desired camera button in the active cameo edits the cameo and displays the video of selected camera Pressing the Enter Pause button exits the Active Cameo mode Selecting Exit Group Edit in the cameo menu displayed when pressing the M...

Страница 22: ...electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of your old appliance will help prevent potential negative cons...

Страница 23: ......

Страница 24: ...llee 84 D 76187 Karlsruhe Tel 49 721 595 1 www buildingtechnologies siemens com 2010 Copyright by Siemens AG Data and design subject to change without notice Supply subject to availability Document no A6V10315395 Edition 06 05 2010 ...

Отзывы: