SIPLUS PSU (6DL3500-8BA)
SIPLUS PSU Power Supply Unit
A5E00854207E
15 of 30
Copyright (C) Siemens AG 2018
V 8.00 released
2018-05-03
5 Technical Data
5.1 Mechanics
Housing
sheet steel, sendzimir galvanized
Dimensions H x W x D
159 mm x 484 mm x 130 mm
Weight
5.0 kg
Screws for fixing the mounting angle at the rack
Thread
M6
Strength category
8.8
Tightening torque
approx. 10 N m (depends on mounting frame)
2
fixing dimensions
DIN 41494
Screws for fixing the mounting angle at the SIPLUS PSU housing
Thread
M6
Strength category
8.8
Tightening torque
6 N m
Screw for fixing the contact shell between M-potential and housing
Thread
M6
Strength category
8.8
Tightening torque
6 N m
5.2 Environmental Conditions
Ambient temperature (up to 35 A)
0 °C to +60 °C
3
Ambient temperature (up to 60 A)
0 °C to +40 °C
Heat flow
natural convection according to chapter 6
Transport and storage temperature
-40 °C to +70 °C
Degree of protection
IP20
according to DIN EN 60529
Mixed gas test
according to DIN EN 60068-2-60, Ke, Method 4
Degree of pollution
2
according to VDE 0110
Overvoltage class
3
according to VDE 0160
Conditions in operation and storage
according to EN 60721-3-3, stationary, weather
protected
climatic environmental conditions
3K3 condensation excluded
chemical active environmental conditions 3C3 salt fog excluded
mechanical environmental conditions
3M4
mechanical active environm. conditions
3S2 sand appearing excluded
usage at altitude
≤ 2000 m
2
Important to a safe electrical connection to the cabinet earth. The minimum tightening torque depends on the
material in which the fixing screws are screwed.
3
When using cabinets it is recommended to install the SIPLUS PSU in the lowermost tier. The maximum ambi-
ent temperature in dependency of the consant current through the feeder diodes is to be considered according
to derating in chapter 6.1.