Siemens SIPLUS CMS Скачать руководство пользователя страница 7

SIPLUS CMS X-Tools - Release Notes 

SIPLUS CMS

English 
Release 2012-09 

 7 / 12

 

 

Device Profile automatically. However, it can become necessary to stop and start the affected Device Profile 
manually in such a case. 

2.10 

Administrator Rights 

Setup.exe must be executed with Windows administrator rights in order to be able to install all redistributable 
files properly. In addition, in case the automated startup type of the 

X-Tools Server

 shall be changed, the 

X-

Tools Server

 also must have Windows administrator rights in order to be able to configure the according Win-

dows service. 

2.11 

Unsupported Record Mode “Changes and Interval” 

Within Device Profiles the “Record Mode” “Changes and Interval” can not be used within the actual version of X-
Tools. 

2.12 

Unsupported Data Format “Big Endian (Motorola, MSB first) using Bit Ar-
rays” 

Using Bit Arrays in Device Profiles the “Data Format” “Big endian (Motorola, MSB first)” can not be used within 
the actual version of X-Tools. 

2.13 

Possible Side-Effect at the Moment of File Splitting 

In case of machines with low performance and high amount of tasks, the available resources at the moment of 
the file splitting can be reduced so that other parts of the system are influenced. In such situations, messages 
about data supervision events and/or about past/future time errors can occur. In order to avoid such situations 
and the involved data loss for a short moment of time, a faster machine must be used and/or less tasks must be 
configured. In cases which are close to the limit of the used machine, also setting of the data supervision time to 
e.g. 10 seconds can reduce this effect. 

2.14 

Massive Amounts of Log Entries may be caused by the Sequence Control 

The sequence control can be used in order to automatically start and stop any other Configuration File. Each of 
such operation causes one or more entries to the System Log and each entry consumes a few bytes of mem-
ory, thus the overall memory usage of the 

X-Tools Server

 may be rising constantly in case of control scripts 

which produce a lot of entries to the System Log. 

Via the “General logging Mode” setting from the global options of the 

X-Tools Server

, the amount of stored log 

entries can be reduced. 

2.15 

Unsupported Update of the ANFs “Avg” and “RMS” 

The input argument has been changed from “PeriodOfTime” to “NumberOfPoints” after V 03.02. In case an Ana-
lyzing Model File or an Analyzing Script File from a version before V 03.02 SP1 is used, this value has to be 
adapted accordingly. 

2.16 

Unsupported Update of the ANF “FFT” and of windowing ANFs within 
Analyzing Scripts 

The input argument “NumberOfPoints” has been removed from all windowing ANFs (“AppBhann”, “AppBlack”, 
“AppBlett”, “AppHamm”, “AppHann”) and from the ANF “FFT” after V 03.02. Now the number of points will be 
taken from the connected ANF “Bffr”. In case an Analyzing Script File from a version before V 03.02 SP1 is 
used, the no more existing input argument has to be removed from the Analyzing Script code. 

2.17 

Unsupported Update of the ANF “OutTCP” within Analyzing Scripts 

The input argument “Mode” has been removed from the ANF “OutTCP” after V 03.02. In case an Analyzing 
Script File from a version before V 03.02 SP1 is used, the no more existing input argument has to be removed 
from the Analyzing Script code. 

Содержание SIPLUS CMS

Страница 1: ...S CMS X Tools Release Notes SIPLUS CMS English Release 2012 09 1 12 Preface 1 Release Notes 2 SIPLUS CMS List of Abbreviations 3 SIPLUS CMS X Tools Release Notes Contact Information 4 English Release 2012 09 ...

Страница 2: ...ission to earth and to tag cir cuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with devices or components from other manufacturers approved or recommended by Siemens Thi...

Страница 3: ... 7 Unsupported Update of the ANF FFT and of windowing ANFs within Analyzing Scripts 2 17 7 Unsupported Update of the ANF OutTCP within Analyzing Scripts 2 18 8 Impaired loading of very big Offline Data Files 2 19 8 Device Name of ION SIMATIC TDC T001 Devices 2 20 8 Legacy IEEE1394 Driver of Windows 7 2 21 8 OPC UA Server Endpoint URL 2 22 8 Multiple OPC UA Server Endpoints 2 23 8 OPC UA Output Dat...

Страница 4: ...IPLUS CMS English Release 2012 09 4 12 9 2 35 Pausing of Monitoring Views in low Memory Situations 2 36 10 Band Recognition through MonSpmEnv 2 37 10 Band Recognition through MonXYEnv 3 11 List of Abbreviations 4 12 Contact Information ...

Страница 5: ... about the functionality which is provided by the Device Management System SIPLUS CMS X Tools User Manual 05 Monitoring System o provides detailed information about the functionality which is provided by the Monitoring System SIPLUS CMS X Tools User Manual 06 Analyzing System o provides detailed information about the functionality which is provided by the Analyzing System SIPLUS CMS X Tools User M...

Страница 6: ...shall be connected via IEEE1394 is restricted to 30 participants 2 3 Usage of IEEE1394 Cables Do not to use cables for the electrical connection of IEEE1394 with a length of 0 5 m or with a length of longer than 4 5 m 2 4 Usage of multiple CTN WatchGuard T001 It is not possible to use multiple CTN WatchGuard T001 at once at the same computer 2 5 Data Supervision Time for CTN WatchGuard T001 Device...

Страница 7: ...ine also setting of the data supervision time to e g 10 seconds can reduce this effect 2 14 Massive Amounts of Log Entries may be caused by the Sequence Control The sequence control can be used in order to automatically start and stop any other Configuration File Each of such operation causes one or more entries to the System Log and each entry consumes a few bytes of mem ory thus the overall memo...

Страница 8: ...r Endpoint URL The X Tools Server uses the combination of Domain Name IP Address and the port number as endpoint URL to connect to an OPC UA server It does not read the provided endpoint URL from the OPC UA server In case the OPC UA server needs the exact endpoint URL definition the X Tools Server may not be able to connect to this OPC UA server Examples IP Address 192 168 10 20 Port 4841 o the re...

Страница 9: ...se a totally deterministic approach for the order of Configuration Files and it does not react in case the maximal free block of the process drops too low The possible effects are that the status of currently suspended and running Configuration Files is dependent to values which are not clearly visi ble to the user and that the status can be different for the same Configuration Files at different ...

Страница 10: ...first call for the further monitoring and would use amplitudes of 0 for the monitoring in case no valid spectrum is provided at the first call 2 37 Band Recognition through MonXYEnv The upper and lower bands which are provided via the inputs of the Analyzing Function MonXYEnv must pro vide a valid buffer at the moment of the first call at the first cycle of the parent Analyzing Model Analyzing Scr...

Страница 11: ...tor IFN Interface Node ION I O Node Input Output Node IPE Interface Profile Editor LPE Loading Profile Editor MDS Master Data System MDX Master Data System Explorer MMS Main Management System MMX Main Management System Explorer MPE Main Profile Editor MTC Monitoring Chart MTS Monitoring System MTX Monitoring System Explorer MVE Monitoring View Editor ODL Offline Data Loader RPN Repeater Node UAE U...

Страница 12: ...S CMS X Tools Release Notes SIPLUS CMS English Release 2012 09 12 12 4 Contact Information Address Siemens AG I IA CE SE Wuerzburger Strasse 121 90766 Fuerth Germany Internet http www siemens com siplus cms ...

Отзывы: