SIPLUS CMS X-Tools - Release Notes
SIPLUS CMS
English
Release 2012-09
10 / 12
2.36
Band Recognition through MonSpmEnv()
The upper and lower bands which are provided via the inputs of the Analyzing Function MonSpmEnv() must
provide a valid spectrum at the moment of the first call (= at the first cycle of the parent Analyzing
Model/Analyzing Script) of MonSpmEnv(). This Analyzing Function always uses the band information from this
first call for the further monitoring and would use amplitudes of 0 for the monitoring in case no valid spectrum is
provided at the first call.
2.37
Band Recognition through MonXYEnv()
The upper and lower bands which are provided via the inputs of the Analyzing Function MonXYEnv() must pro-
vide a valid buffer at the moment of the first call (= at the first cycle of the parent Analyzing Model/Analyzing
Script) of MonXYEnv(). This Analyzing Function always uses the band information from this first call for the fur-
ther monitoring and would use values of 0 for the monitoring in case no valid buffer is provided at the first call.