Parameterizing machine data
3.2 Parameterizing the control using machine data
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
97
3.2
Parameterizing the control using machine data
3.2.1
Machine data for setting actual value, scratching, PRESET
Access levels for system frames
The machine manufacturer or user can assign the access levels for system frames as well
as for individual functions and data areas using display machine data. Access levels 0 to 3
can also be entered.
Default setting: This machine data is predefined with access level "7". This means that
access is granted to all these data areas and functions when the keylock switch is in the 0
position.
Access levels are available for the following system frames:
System frame
MD number Designation/meaning
ToolFrame
9183
$MM_USER_CLASS_WRITE_TOOLFRAME
Protection level write toolholder
PartFrame
9184
$MM_USER_CLASS_WRITE_PARTFRAME
Protection level write tool reference point
WPFrame
9185
$MM_USER_CLASS_WRITE_WPFRAME
Protection level write workpiece reference point
CYCFrame
9186
$MM_USER_CLASS_WRITE_CYCFRAME
Protection level write cycle frame
TraFrame
9187
$MM_USER_CLASS_WRITE_TRAFRAME
Protection level write transformation frame
ExtFrame
9188
$MM_USER_CLASS_WRITE_EXTFRAME
Protection level write external WO
SetFrame
9210
$MM_USER_CLASS_WRITE_ZOA
Protection level write settable WO
Function
The behavior of the Scratching and Set actual value, PRESET functions is influenced by a
number of machine data. The selected settings affect operation (how softkeys and values
are displayed, and how the entered values are stored).
With the introduction of system frames, two variants are available for the functions. The
variants are differentiated by a channel-specific machine data:
MD 28082: $MC_SYSTEM_FRAME_MASK
Bit:
0
Actual value setting, scratching
1
External work offset
2
TCARR, PAROT
3
TOROT, TOFRAME
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...