NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
393
ADI4
Because a ADI4 module does not support acyclic communication on the PROFIBUS, we
recommend entering value 4 as the drive type for any drive operated via ADI4:
●
MD13080 $MN_DRIVE_TYP_DP[n] = 4
Note
We recommend entering drive type 4 manually for drives connected via ADI4:
•
MD13080 $MN_DRIVE_TYPE_DP[n] = 4
Table 11-16 Drive configuration: Machine data
Number
Name
Name/remarks
General ($MN_ ... )
13050
DRIVE_LOGIC_ADDRESS[n]
Logical I/O address of drive
13060
DRIVE_TELEGRAM_TYPE[n]
Drive message frame type for the drives connected to
PROFIBUS DP
13070
DRIVE_FUNCTION_MASK[n]
611U-specific DP functions in use
13080
DRIVE_TYPE_DP[n]
Drive type PROFIBUS DP
11.5.4
Setpoint/actual value channels
Note
In order to guarantee that the control runs up reliably, all machine axes are declared as
simulation axes (without hardware).
•
MD30130 $MA_CTRLOUT_TYPE (output type of setpoint value) = 0
•
MD30240 $MA_ENC_TYPE (actual value acquisition mode) = 0
Traversing of the axes in servo mode is simulated without speed setpoint output, and no
hardware-specific alarms are output.
The following machine data can be used to select whether the interface signals of a
simulation axis are output at the PLC interface (e.g. during program test, if there is no drive
hardware):
MD30350 $MA_SIMU_AX_VDI_OUTPUT (output of axis signals with simulation axes)
Assignment of the setpoint/actual value channels
The following parameters must be defined for each machine axis that a drive is to be
assigned to:
●
a setpoint channel and
●
at least one actual-value channel
A second actual-value channel can be set up as an option.
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...