PROFIBUS DP Communication
8.6 DP slave MCP 310
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
259
Additional I/Os
The function: "Additional I/Os" transfers the data of all non-standard I/Os:
●
Direct keys
●
Customer keys: 6 signals (bit 0 to bit 6)
●
Rotary switch
with the following distribution:
●
Input data: 5 bytes
QGURWDU\
VZLWFK
VWURWDU\
VZLWFK
'LUHFWFRQWURONH\V
23
&XVWRPHU
NH\V
+LJK%\WH
/RZ%\WH
●
Output data: 2 bytes
5HVHUYHG&XVWRPHU
DOZD\V/('V
/RZ%\WH
+LJK%\WH
8.6.4
Configure MCP 310 DP slave
The chapter describes the configuration of an MCP 310 DP slave with the help of the
configuration of a SIMATIC S7 project displayed in the following figure.
The configuration comprises the following modules:
●
SIMATIC Station 300 with SINUMERIK 810D/840D and PLC 317-2DP
●
SINUMERIK MCP with module: standard, handwheel, extended
The following steps must be performed within the framework of the S7 project to configure
the MCP 310 DP slave:
1.
Insertion of the MCP 310 DP slave in the configuration
(see following figure: 1)
2.
Setting the PROFIBUS address
3.
Insertion of the corresponding modules in the MCP 310 DP slave as a function of the
desired functions.
(see following figure: 2)
4.
Setting the I/O addresses of the individual slots
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...