Switch S2
6FKDOWHU6
Switch position: "ON" is at the top.
Table 7-9
Switch S2 is set as delivered
1
2
3
4
5
6
7
8
9
10
Meaning
ON
ON PLC I/O Interface
OFF OFF OFF OFF OFF OFF OFF OFF
PROFINET address "0"
The two switches S2-9 and S2-10 must remain set to "ON".
The switches S2-1 to S2-8 define the PROFINET address. For a SINUMERIK 828D,
the address "64" must always be assigned to the MCP.
Table 7-10
Settings of switch S2
1
2
3
4
5
6
7
8
9
10
Meaning
ON
ON
ON
OFF OFF OFF OFF OFF OFF
OFF
PROFINET address "64"
7.1.4
Parameterization
The specifications for assigning input and output bytes listed in the tables are set as standard
addresses in the PLC by setting the following machine data:
MD12986 PLC_DEACT_IMAGE_LADDR_IN[6] = -1
Standard input image
Table 7-11
Input image MCP 483C PN
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Spindle override
Operating mode
EB112
D (2
3
)
C (2
2
)
B (2
1
)
A (2
0
)
JOG
TEACH IN
MDA
AUTO
Machine function
EB113
REPOS
REF.
var. INC
10000 INC
1000 INC
100 INC
10 INC
1 INC
EB114
Keyswitch
position 0
Keyswitch
position 2
Spindle
Start
*Spindle
Stop
Feed
Start
*Feed
Stop
NC
start
*NC
Stop
Connectable components
7.1 MCP 483C PN
PPU
104
Manual, 01/2014, 6FC5397-2DP40-3BA3