Parame‐
ter
Function
Adjustment range
p1250
Vdc_controller proportional gain
0.00 ... 10.00
Factory setting: 1.00
Display of the switch-on level of the vdc-max controller.
Parame‐
ter
Function
Adjustment range
p1251
Vdc_controller integral time
1 ... 1000 ms
Factory setting: 40 ms
Setting for the integral-action time of the vdc controller.
The effective integral time can be determined using p1243.
Parame‐
ter
Function
Adjustment range
p1252
Vdc_controller derivative-action time
1 ... 1000 ms
Factory setting: 1 ms
Setting for the derivative-action time of the vdc controller.
The active derivative-action time can be determined using p1243.
Parame‐
ter
Function
Adjustment range
p1254
Vdc_max_controller automatic ON level de‐
tection
1 / 0
Factory setting: 0
Activates/deactivates automatic sensing of the switch-on level for the Vdc-max controller.
Values:
0: Automatic detection inhibited.
1: Automatic acquisition enabled
Settings
Parameter p1240 functions as a release:
● 0: Controller inhibited
● 1: Controller enabled
You use p1242 to define the starting point of the vdc-max controller. The starting point is the
maximum value of the DC link voltage that cannot be exceeded. If the DC link voltage is below
the starting point, the controller remains inactive. The controller gain can be changed by means
of p1250. The set ramp-down remains inactive while the vdc_max controller is active. The ramp-
down time increases the more excess kinetic energy is stored in the drive train.
Operation
8.5 Functions
SINAMICS SM150 6SL3815-7NP41-0AA1
Operating Instructions Rev.201910281301 EXAMPLE
139
Содержание SINAMICS SM150 6SL3815-7NP41-0AA1
Страница 2: ...28 10 2019 13 01 V32 00 ...
Страница 116: ...Start up SINAMICS SM150 6SL3815 7NP41 0AA1 116 Operating Instructions Rev 201910281301 EXAMPLE ...
Страница 176: ...Maintenance 9 5 Repair SINAMICS SM150 6SL3815 7NP41 0AA1 176 Operating Instructions Rev 201910281301 EXAMPLE ...